Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FAIL SAFE DESIGN Search Results

    FAIL SAFE DESIGN Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    Safety-Light-Curtain Renesas Electronics Corporation Safety Light Curtain Reference Design Visit Renesas Electronics Corporation
    DE6B3KJ151KA4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6B3KJ471KB4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6E3KJ152MN4A Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6B3KJ101KA4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd

    FAIL SAFE DESIGN Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    80C52

    Abstract: C504
    Text: Fail Safe Mechanisms C504 8 Fail Safe Mechanisms The C504 offers enhanced fail safe mechanisms, which allow an automatic recovery from software upset or hardware failure : – a programmable watchdog timer WDT , with variable time-out period from 512 µs up to


    Original
    PDF

    mtl4501-sr

    Abstract: MTL5501-SR IEC61508-2 iec61508 relay 29ma IEC61508
    Text: MTL4501-SR MTL5501-SR MTL4501-SR Hazardous area Safe area FAIL-SAFE SWITCH/PROXIMITYDETECTOR INTERFACE Resistors must always be fitted for switch inputs with LFD 6 5 4 1k4W With the MTLx501-SR, a fail-safe switch/proximity detector located in the hazardous area can control an isolated fail-safe


    Original
    MTL4501-SR MTL5501-SR MTLx501-SR, MTLx501-SR 1232mW 1160mW 1392mW 1200mW mtl4501-sr MTL5501-SR IEC61508-2 iec61508 relay 29ma IEC61508 PDF

    80C52

    Abstract: SAB-C502
    Text: Fail Safe Mechanisms 8 Fail Safe Mechanisms The SAB-C502 offers enhanced fail safe mechanisms, which allow an automatic recovery from software upset or hardware failure : – a programmable watchdog timer WDT , with variable time-out period from 512 µs up to


    Original
    SAB-C502 80C52 PDF

    SLLA082

    Abstract: SN65LVDT32A SN65LVDS32A
    Text: Application Report SLLA082 - August 2000 The Active Fail-Safe Feature of the SN65LVDS32A Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Current LVDS fail-safe solutions require either external components


    Original
    SLLA082 SN65LVDS32A LVDS32A) SN65LVDT32A SN65LVDS32A PDF

    Philips sbc 345 Temperature Control

    Abstract: TJA1054A UJA1061TW BAT14 TJA1055 HTSSOP32 ISO11898-3 J2602 TJA1020 TJA1054
    Text: UJA1061 Fault-tolerant CAN/LIN fail-safe system basis chip Rev. 03 — 27 June 2006 Preliminary data sheet 1. General description The UJA1061 fail-safe System Basis Chip fail-safe SBC replaces basic discrete components which are common in every Electronic Control Unit (ECU) with a Controller


    Original
    UJA1061 UJA1061 ISO11898-3 TJA1054, TJA1054A TJA1055 Philips sbc 345 Temperature Control UJA1061TW BAT14 TJA1055 HTSSOP32 J2602 TJA1020 TJA1054 PDF

    SLLA082A

    Abstract: WINDOW COMPARATOR LVDS32 SN65LVDS32B SN65LVDS3486B SN65LVDS9637B SN65LVDT32B SN65LVDT3486B SN65LVDT9637B LVDS32B
    Text: Application Report SLLA082A - November 2000 The Active Fail-Safe Feature of the SN65LVDS32B Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Current LVDS fail-safe solutions require either external components


    Original
    SLLA082A SN65LVDS32B LVDS32B) WINDOW COMPARATOR LVDS32 SN65LVDS32B SN65LVDS3486B SN65LVDS9637B SN65LVDT32B SN65LVDT3486B SN65LVDT9637B LVDS32B PDF

    WINDOW COMPARATOR

    Abstract: LVDS32 SN65LVDS32B SN65LVDS33 SN65LVDS3486B SN65LVDS9637B SN65LVDT32B SN65LVDT3486B SN65LVDT9637B LVDS32B
    Text: Application Report SLLA082B - October 2001 Active Fail-Safe in TI’s LVDS Receivers Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Many innovative LVDS fail-safe solutions require either external


    Original
    SLLA082B SN65LVDS32B LVDS32B) WINDOW COMPARATOR LVDS32 SN65LVDS33 SN65LVDS3486B SN65LVDS9637B SN65LVDT32B SN65LVDT3486B SN65LVDT9637B LVDS32B PDF

    MS27661

    Abstract: No abstract text available
    Text: Amphenol Aerospace Series I, LJT Breakaway Fail Safe Lanyard Release Plug How to Order, cont. HOW TO ORDER - BY MILITARY PART NUMBER FAIL SAFE MS27661 1. 2. 3. MS Number Service Class MS27661 T HOW TO ORDER - BY COMMERCIAL PART NUMBER FAIL SAFE 88-5388 OR 91-5388


    Original
    MS27661 MS27661 MIL-DTL-38999, PDF

    Untitled

    Abstract: No abstract text available
    Text: SY54016R Product Brief Low Voltage 1.2V/1.8V CML Differential Line Driver/Receiver with Fail Safe Input 3.2Gbps, 2.5GHz Description The SY54016R is a fully differential, low voltage 1.2V/1.8V CML Line Driver/Receiver with Fail Safe Input. The Fail Safe Input includes a dedicated circuit to sense the


    Original
    SY54016R SY54016R 100mVPK 200mVPP) 100mndia SE-171 M9999-031208 PDF

    Untitled

    Abstract: No abstract text available
    Text: SY54017R Product Brief Low Voltage 1.2V/1.8V CML 2:1 Multiplexer with Fail Safe Input 3.2Gbps, 2.5GHz Description The SY54017R is a fully differential, low voltage 1.2V/1.8V CML 2:1 MUX with Fail Safe Inputs. The Fail Safe Inputs include a dedicated circuit to sense the amplitude of the


    Original
    SY54017R SY54017R 100mVPK 200mVPP) 100mV SE-171 M9999-031208 PDF

    Untitled

    Abstract: No abstract text available
    Text: LJT Breakaway Fail Safe lanyard release plug how to order, cont. HOW TO ORDER - BY MILITARY PART NUMBER FAIL SAFE MS27661 MS27661 T 17 B HOW TO ORDER - BY PROPRIETARY PART NUMBER FAIL SAFE 88-5388 OR 91-5388 35 P A 88 – 5388 MS Number Finish Service Class


    Original
    MS27661 MIL-DTL-38999, PDF

    SO20

    Abstract: U6809B dec-97 202
    Text: U6809B Fail-Safe IC Description The U6809B is designed to support the fail-safe function of a safety-critical system e.g., ABS. It includes a relay driver, two independent short-circuit-protected lamp drivers which are supplied by redundant ground lines, two


    Original
    U6809B U6809B 250-mA D-74025 03-Dec-97 SO20 dec-97 202 PDF

    5W55

    Abstract: No abstract text available
    Text: U6809B Fail-Safe IC Description The U6809B is designed to support the fail-safe function of a safety-critical system e.g., ABS. It includes a relay driver, two independent short-circuit-protected lamp drivers which are supplied by redundant ground lines, two


    Original
    U6809B U6809B 250-mA D-74025 02-Oct-98 5W55 PDF

    Untitled

    Abstract: No abstract text available
    Text: Series III, TV Breakaway Fail Safe Connectors Quick-Disconnect with an Axial Pull of Lanyard Amphenol Aerospace 38999 Amphenol Tri-Start Breakaway Fail Safe Connectors provide unequaled performance in environments requiring instant disengagement. High Speed


    Original
    D38999/20 MIL-DTL-38999/29, MIL-STD-1760 PDF

    RS484

    Abstract: RS-484 AN1076 maxim rs485 reluctance APP1076 MAX3095 MAX3096 vr sensor Steel bar
    Text: Maxim > App Notes > INTERFACE CIRCUITS Keywords: RS-485, rs484, EIA/TIA-485, fail-safe, variable-reluctance sensor, low-speed, medium speed, ESD protected, rs485 transceiver May 24, 2002 APPLICATION NOTE 1076 Fail-Safe, Low-Speed, Variable-Reluctance Sensors


    Original
    RS-485, rs484, EIA/TIA-485, rs485 RS-485 MAX3096 com/an1076 MAX3095: MAX3096: AN1076, RS484 RS-484 AN1076 maxim rs485 reluctance APP1076 MAX3095 vr sensor Steel bar PDF

    car ecu wiring system service manual

    Abstract: cars ecu UJA106x NXP Logic fmea ISO11898-2 "bat 42" BAT14 PESD1LIN s34 schottky diode tja1040
    Text: NXP Semiconductors Automotive Innovation Center, Germany APPLICATION HINTS Version 2.9 Fail-safe System Basis Chips UJA106x Application Hints Fail-Safe CAN / LIN System Basis Chips UJA1061, UJA1065, UJA1066, UJA1069 Version 2.9 Authors: Thorsten Kauder, Matthias Muth, Martin Wagner


    Original
    UJA106x UJA1061, UJA1065, UJA1066, UJA1069 UJA1062 AH0802 UJA106x car ecu wiring system service manual cars ecu NXP Logic fmea ISO11898-2 "bat 42" BAT14 PESD1LIN s34 schottky diode tja1040 PDF

    Untitled

    Abstract: No abstract text available
    Text: LJT Breakaway Fail Safe quick-disconnect with an axial pull of lanyard Amphenol LJT Breakaway Fail Safe Connectors provide unequalled performance in environments requiring instant disengagement. Designed to provide quick disconnect of a connector plug and receptacle with an axial pull on the lanyard, the


    Original
    MIL-DTL-38999 MIL-C-26482, MIL-C-83723) PDF

    car ecu wiring system service manual

    Abstract: GP010 K-line interface AH0802 can muth ecu repair tja1040 TJA1054 vw connector principal BAT42
    Text: NXP Semiconductors Automotive Innovation Center, Germany APPLICATION HINTS Version 2.8 Fail-safe System Basis Chips UJA106x Application Hints Fail-Safe CAN / LIN System Basis Chips UJA1061, UJA1065, UJA1066, UJA1069 Version 2.8 Authors: Thorsten Kauder, Matthias Muth, Martin Wagner


    Original
    UJA106x UJA1061, UJA1065, UJA1066, UJA1069 UJA1062 AH0802 UJA106x car ecu wiring system service manual GP010 K-line interface can muth ecu repair tja1040 TJA1054 vw connector principal BAT42 PDF

    Untitled

    Abstract: No abstract text available
    Text: Obsolete Device DS78LS120 DS78LS120 Dual Differential Line Receiver Noise Filtering and Fail-Safe Literature Number: SNLS370B Obsolete Device DS78LS120 Dual Differential Line Receiver (Noise Filtering and Fail-Safe) General Description The DS78LS120 is a high performance, dual differential, TTL


    Original
    DS78LS120 DS78LS120 SNLS370B PDF

    ds75150

    Abstract: No abstract text available
    Text: Obsolete Device DS78LS120 DS78LS120 Dual Differential Line Receiver Noise Filtering and Fail-Safe Literature Number: SNLS370B September 1999 DS78LS120 Dual Differential Line Receiver (Noise Filtering and Fail-Safe) General Description The DS78LS120 is a high performance, dual differential, TTL


    Original
    DS78LS120 DS78LS120 SNLS370B ds75150 PDF

    U6808B

    Abstract: t45v
    Text: U6808B Special Fail-Safe IC Description The U6808B is designed to support the fail-safe function of a safety critical system e.g. ABS. It includes a relay driver, a watchdog controlled by an external R/C-network and a reset circuit initiated by an over- and undervoltage


    Original
    U6808B U6808B 250-mA MIL-STD-883 D-74025 18-Jan-01 t45v PDF

    U6808B

    Abstract: 11-pin relay pin out diagram
    Text: U6808B Special Fail-Safe IC Description The U6808B is designed to support the fail-safe function of a safety critical system e.g. ABS. It includes a relay driver, a watchdog controlled by an external R/C-network and a reset circuit initiated by an over- and undervoltage


    Original
    U6808B U6808B 250-mA D-74025 03-Dec-97 11-pin relay pin out diagram PDF

    Schmersal AZM 160

    Abstract: 3XXXM AZM160 aes 3335
    Text: Fail-Safe Standstill Monitor FWS 1106 DC-Version • 1 Enabling path • Reset-input r • Fail-safe recognition of a machine standstill with one or two inductive proxim ity switches and an additional standstill signal • Fail-safe controlling of solenoid Interlocks


    OCR Scan
    PDF

    3XXXM

    Abstract: No abstract text available
    Text: Fail-Safe Delay Timer AZS 2305 AC / DC-Version •3 Enabling paths General information The fail-safe delay tim er AZS 2305 has the following features: • Fail-safe monitoring of a set time value • Adjustable time from 0.1 s to 99 min • Compatible with SCHMERSAL s safety com ponents


    OCR Scan
    89/392/EW 3XXXM PDF