80C52
Abstract: C504
Text: Fail Safe Mechanisms C504 8 Fail Safe Mechanisms The C504 offers enhanced fail safe mechanisms, which allow an automatic recovery from software upset or hardware failure : – a programmable watchdog timer WDT , with variable time-out period from 512 µs up to
|
Original
|
|
PDF
|
mtl4501-sr
Abstract: MTL5501-SR IEC61508-2 iec61508 relay 29ma IEC61508
Text: MTL4501-SR – MTL5501-SR MTL4501-SR Hazardous area Safe area FAIL-SAFE SWITCH/PROXIMITYDETECTOR INTERFACE Resistors must always be fitted for switch inputs with LFD 6 5 4 1k4W With the MTLx501-SR, a fail-safe switch/proximity detector located in the hazardous area can control an isolated fail-safe
|
Original
|
MTL4501-SR
MTL5501-SR
MTLx501-SR,
MTLx501-SR
1232mW
1160mW
1392mW
1200mW
mtl4501-sr
MTL5501-SR
IEC61508-2
iec61508 relay
29ma
IEC61508
|
PDF
|
80C52
Abstract: SAB-C502
Text: Fail Safe Mechanisms 8 Fail Safe Mechanisms The SAB-C502 offers enhanced fail safe mechanisms, which allow an automatic recovery from software upset or hardware failure : – a programmable watchdog timer WDT , with variable time-out period from 512 µs up to
|
Original
|
SAB-C502
80C52
|
PDF
|
SLLA082
Abstract: SN65LVDT32A SN65LVDS32A
Text: Application Report SLLA082 - August 2000 The Active Fail-Safe Feature of the SN65LVDS32A Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Current LVDS fail-safe solutions require either external components
|
Original
|
SLLA082
SN65LVDS32A
LVDS32A)
SN65LVDT32A
SN65LVDS32A
|
PDF
|
Philips sbc 345 Temperature Control
Abstract: TJA1054A UJA1061TW BAT14 TJA1055 HTSSOP32 ISO11898-3 J2602 TJA1020 TJA1054
Text: UJA1061 Fault-tolerant CAN/LIN fail-safe system basis chip Rev. 03 — 27 June 2006 Preliminary data sheet 1. General description The UJA1061 fail-safe System Basis Chip fail-safe SBC replaces basic discrete components which are common in every Electronic Control Unit (ECU) with a Controller
|
Original
|
UJA1061
UJA1061
ISO11898-3
TJA1054,
TJA1054A
TJA1055
Philips sbc 345 Temperature Control
UJA1061TW
BAT14
TJA1055
HTSSOP32
J2602
TJA1020
TJA1054
|
PDF
|
SLLA082A
Abstract: WINDOW COMPARATOR LVDS32 SN65LVDS32B SN65LVDS3486B SN65LVDS9637B SN65LVDT32B SN65LVDT3486B SN65LVDT9637B LVDS32B
Text: Application Report SLLA082A - November 2000 The Active Fail-Safe Feature of the SN65LVDS32B Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Current LVDS fail-safe solutions require either external components
|
Original
|
SLLA082A
SN65LVDS32B
LVDS32B)
WINDOW COMPARATOR
LVDS32
SN65LVDS32B
SN65LVDS3486B
SN65LVDS9637B
SN65LVDT32B
SN65LVDT3486B
SN65LVDT9637B
LVDS32B
|
PDF
|
WINDOW COMPARATOR
Abstract: LVDS32 SN65LVDS32B SN65LVDS33 SN65LVDS3486B SN65LVDS9637B SN65LVDT32B SN65LVDT3486B SN65LVDT9637B LVDS32B
Text: Application Report SLLA082B - October 2001 Active Fail-Safe in TI’s LVDS Receivers Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Many innovative LVDS fail-safe solutions require either external
|
Original
|
SLLA082B
SN65LVDS32B
LVDS32B)
WINDOW COMPARATOR
LVDS32
SN65LVDS33
SN65LVDS3486B
SN65LVDS9637B
SN65LVDT32B
SN65LVDT3486B
SN65LVDT9637B
LVDS32B
|
PDF
|
MS27661
Abstract: No abstract text available
Text: Amphenol Aerospace Series I, LJT Breakaway Fail Safe Lanyard Release Plug How to Order, cont. HOW TO ORDER - BY MILITARY PART NUMBER FAIL SAFE MS27661 1. 2. 3. MS Number Service Class MS27661 T HOW TO ORDER - BY COMMERCIAL PART NUMBER FAIL SAFE 88-5388 OR 91-5388
|
Original
|
MS27661
MS27661
MIL-DTL-38999,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SY54016R Product Brief Low Voltage 1.2V/1.8V CML Differential Line Driver/Receiver with Fail Safe Input 3.2Gbps, 2.5GHz Description The SY54016R is a fully differential, low voltage 1.2V/1.8V CML Line Driver/Receiver with Fail Safe Input. The Fail Safe Input includes a dedicated circuit to sense the
|
Original
|
SY54016R
SY54016R
100mVPK
200mVPP)
100mndia
SE-171
M9999-031208
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SY54017R Product Brief Low Voltage 1.2V/1.8V CML 2:1 Multiplexer with Fail Safe Input 3.2Gbps, 2.5GHz Description The SY54017R is a fully differential, low voltage 1.2V/1.8V CML 2:1 MUX with Fail Safe Inputs. The Fail Safe Inputs include a dedicated circuit to sense the amplitude of the
|
Original
|
SY54017R
SY54017R
100mVPK
200mVPP)
100mV
SE-171
M9999-031208
|
PDF
|
Untitled
Abstract: No abstract text available
Text: LJT Breakaway Fail Safe lanyard release plug how to order, cont. HOW TO ORDER - BY MILITARY PART NUMBER FAIL SAFE MS27661 MS27661 T 17 B HOW TO ORDER - BY PROPRIETARY PART NUMBER FAIL SAFE 88-5388 OR 91-5388 35 P A 88 – 5388 MS Number Finish Service Class
|
Original
|
MS27661
MIL-DTL-38999,
|
PDF
|
SO20
Abstract: U6809B dec-97 202
Text: U6809B Fail-Safe IC Description The U6809B is designed to support the fail-safe function of a safety-critical system e.g., ABS. It includes a relay driver, two independent short-circuit-protected lamp drivers which are supplied by redundant ground lines, two
|
Original
|
U6809B
U6809B
250-mA
D-74025
03-Dec-97
SO20
dec-97 202
|
PDF
|
5W55
Abstract: No abstract text available
Text: U6809B Fail-Safe IC Description The U6809B is designed to support the fail-safe function of a safety-critical system e.g., ABS. It includes a relay driver, two independent short-circuit-protected lamp drivers which are supplied by redundant ground lines, two
|
Original
|
U6809B
U6809B
250-mA
D-74025
02-Oct-98
5W55
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Series III, TV Breakaway Fail Safe Connectors Quick-Disconnect with an Axial Pull of Lanyard Amphenol Aerospace 38999 Amphenol Tri-Start Breakaway Fail Safe Connectors provide unequaled performance in environments requiring instant disengagement. High Speed
|
Original
|
D38999/20
MIL-DTL-38999/29,
MIL-STD-1760
|
PDF
|
|
RS484
Abstract: RS-484 AN1076 maxim rs485 reluctance APP1076 MAX3095 MAX3096 vr sensor Steel bar
Text: Maxim > App Notes > INTERFACE CIRCUITS Keywords: RS-485, rs484, EIA/TIA-485, fail-safe, variable-reluctance sensor, low-speed, medium speed, ESD protected, rs485 transceiver May 24, 2002 APPLICATION NOTE 1076 Fail-Safe, Low-Speed, Variable-Reluctance Sensors
|
Original
|
RS-485,
rs484,
EIA/TIA-485,
rs485
RS-485
MAX3096
com/an1076
MAX3095:
MAX3096:
AN1076,
RS484
RS-484
AN1076
maxim rs485
reluctance
APP1076
MAX3095
vr sensor
Steel bar
|
PDF
|
car ecu wiring system service manual
Abstract: cars ecu UJA106x NXP Logic fmea ISO11898-2 "bat 42" BAT14 PESD1LIN s34 schottky diode tja1040
Text: NXP Semiconductors Automotive Innovation Center, Germany APPLICATION HINTS Version 2.9 Fail-safe System Basis Chips UJA106x Application Hints Fail-Safe CAN / LIN System Basis Chips UJA1061, UJA1065, UJA1066, UJA1069 Version 2.9 Authors: Thorsten Kauder, Matthias Muth, Martin Wagner
|
Original
|
UJA106x
UJA1061,
UJA1065,
UJA1066,
UJA1069
UJA1062
AH0802
UJA106x
car ecu wiring system service manual
cars ecu
NXP Logic fmea
ISO11898-2
"bat 42"
BAT14
PESD1LIN
s34 schottky diode
tja1040
|
PDF
|
Untitled
Abstract: No abstract text available
Text: LJT Breakaway Fail Safe quick-disconnect with an axial pull of lanyard Amphenol LJT Breakaway Fail Safe Connectors provide unequalled performance in environments requiring instant disengagement. Designed to provide quick disconnect of a connector plug and receptacle with an axial pull on the lanyard, the
|
Original
|
MIL-DTL-38999
MIL-C-26482,
MIL-C-83723)
|
PDF
|
car ecu wiring system service manual
Abstract: GP010 K-line interface AH0802 can muth ecu repair tja1040 TJA1054 vw connector principal BAT42
Text: NXP Semiconductors Automotive Innovation Center, Germany APPLICATION HINTS Version 2.8 Fail-safe System Basis Chips UJA106x Application Hints Fail-Safe CAN / LIN System Basis Chips UJA1061, UJA1065, UJA1066, UJA1069 Version 2.8 Authors: Thorsten Kauder, Matthias Muth, Martin Wagner
|
Original
|
UJA106x
UJA1061,
UJA1065,
UJA1066,
UJA1069
UJA1062
AH0802
UJA106x
car ecu wiring system service manual
GP010
K-line interface
can muth
ecu repair
tja1040
TJA1054
vw connector principal
BAT42
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Obsolete Device DS78LS120 DS78LS120 Dual Differential Line Receiver Noise Filtering and Fail-Safe Literature Number: SNLS370B Obsolete Device DS78LS120 Dual Differential Line Receiver (Noise Filtering and Fail-Safe) General Description The DS78LS120 is a high performance, dual differential, TTL
|
Original
|
DS78LS120
DS78LS120
SNLS370B
|
PDF
|
ds75150
Abstract: No abstract text available
Text: Obsolete Device DS78LS120 DS78LS120 Dual Differential Line Receiver Noise Filtering and Fail-Safe Literature Number: SNLS370B September 1999 DS78LS120 Dual Differential Line Receiver (Noise Filtering and Fail-Safe) General Description The DS78LS120 is a high performance, dual differential, TTL
|
Original
|
DS78LS120
DS78LS120
SNLS370B
ds75150
|
PDF
|
U6808B
Abstract: t45v
Text: U6808B Special Fail-Safe IC Description The U6808B is designed to support the fail-safe function of a safety critical system e.g. ABS. It includes a relay driver, a watchdog controlled by an external R/C-network and a reset circuit initiated by an over- and undervoltage
|
Original
|
U6808B
U6808B
250-mA
MIL-STD-883
D-74025
18-Jan-01
t45v
|
PDF
|
U6808B
Abstract: 11-pin relay pin out diagram
Text: U6808B Special Fail-Safe IC Description The U6808B is designed to support the fail-safe function of a safety critical system e.g. ABS. It includes a relay driver, a watchdog controlled by an external R/C-network and a reset circuit initiated by an over- and undervoltage
|
Original
|
U6808B
U6808B
250-mA
D-74025
03-Dec-97
11-pin relay pin out diagram
|
PDF
|
Schmersal AZM 160
Abstract: 3XXXM AZM160 aes 3335
Text: Fail-Safe Standstill Monitor FWS 1106 DC-Version • 1 Enabling path • Reset-input r • Fail-safe recognition of a machine standstill with one or two inductive proxim ity switches and an additional standstill signal • Fail-safe controlling of solenoid Interlocks
|
OCR Scan
|
|
PDF
|
3XXXM
Abstract: No abstract text available
Text: Fail-Safe Delay Timer AZS 2305 AC / DC-Version •3 Enabling paths General information The fail-safe delay tim er AZS 2305 has the following features: • Fail-safe monitoring of a set time value • Adjustable time from 0.1 s to 99 min • Compatible with SCHMERSAL s safety com ponents
|
OCR Scan
|
89/392/EW
3XXXM
|
PDF
|