Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    EN60255 Search Results

    EN60255 Datasheets (1)

    Part ECAD Model Manufacturer Description Curated Type PDF
    EN60255 Thiim TEMPERATURE TRANSMITTER Original PDF

    EN60255 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    ER0046EJ

    Abstract: No abstract text available
    Text: DATA S H E E T MINIATURE SIGNAL RELAY EE2 SERIES Compact and lightweight, High breakdown voltage, Surface mounting type DESCRIPTION The EE2 series surface-mounting type sustaining high-performance of NEC EC2 series. FEATURES Compact and light weight ™ 2 form c contact arrangement


    Original
    PDF E73266) LR46266) ER0046EJ

    omron g5lb -1-25

    Abstract: omron g5lb 1-25 omron g5lb 1-25 12VDC omron g5lb -1-25 12 vdc E41643 EN61810-1 LR31928 relay pcb 24 v spdt g5lb-1 omron g5lb-1-25
    Text: PCB Relay G5LB A Cubic, Single-pole 10-A Power Relay • 19.6 x 15.6 × 15.2 mm L × W × H Subminiature “Sugar Cube” relay. ■ Low coil power consumption (360 mW). ■ UL class B and class F insulation available. ■ Models with CTI >175 and CTI > 250 available.


    Original
    PDF EN61810 G5LB-14 k128-E1-02 omron g5lb -1-25 omron g5lb 1-25 omron g5lb 1-25 12VDC omron g5lb -1-25 12 vdc E41643 EN61810-1 LR31928 relay pcb 24 v spdt g5lb-1 omron g5lb-1-25

    pull type solenoid coils

    Abstract: R99-04 relay omron diagram triac catalog E41643 LR35535 G7J-4A-B
    Text: Power Relay G7J A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor • Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads. • No contact chattering for momentary voltage drops up to 50%


    Original
    PDF UL94V-0-qualifying) pull type solenoid coils R99-04 relay omron diagram triac catalog E41643 LR35535 G7J-4A-B

    omron g5r

    Abstract: A282 A300 E41643
    Text: PCB Relay G5RL A Single-pole, 16-A Power Relay • Low profile: 15.7 mm in height • Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm • Inrush peak currents up to 100 A DC models only


    Original
    PDF J01C-E-01 omron g5r A282 A300 E41643

    Untitled

    Abstract: No abstract text available
    Text: 3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: 306 373-5505 Fx: (306) 374-2245 www.littelfuse.com/relayscontrols SE-701 MANUAL GROUND-FAULT MONITOR Revision 10-C-072414 Copyright 2014 by Littelfuse Startco All rights reserved. Document Number: PM-1040-EN


    Original
    PDF SE-701 10-C-072414 PM-1040-EN 10-B-102113 EFCT-26 SE-CS30-26.

    k30206

    Abstract: SENSOR HALL 946 s 452 kd 2060 transistor
    Text: Complete Catalogue 4/2015 Residual current monitoring in grounded power supply systems with residual current relay type RCM1000V and current transformers type STWA3D Meas uring, C ontr olling, Moni t o r i n g o n h i g h e s t l e v e l Editorial Besser, schneller, innovativer, das ist unsere Maxime bei


    Original
    PDF RCM1000V D-74523 k30206 SENSOR HALL 946 s 452 kd 2060 transistor

    IEC60255

    Abstract: No abstract text available
    Text: Multilin 345 TRANSFORMER PROTECTION SYSTEM Intuitive protection and advanced communications for power transformers KEY BENEFITS • Proven and secure high-speed protection system for power transformers • Powerful communication capabilities allowing seamless


    Original
    PDF GEA-12778K IEC60255

    IEC60255

    Abstract: LR46266
    Text: DATA S H E E T MINIATURE SIGNAL RELAY EE2 SERIES Compact and lightweight, High breakdown voltage, Surface mounting type DESCRIPTION The EE2 series surface-mounting type sustaining high-performance of NEC EC2 series. FEATURES Compact and light weight ™ 2 form c contact arrangement


    Original
    PDF E73266) LR46266) DE0202 IEC60255 LR46266

    EN61000-4-2

    Abstract: No abstract text available
    Text: Three-phase Voltage Relay K8AB-PW Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. • Monitor overvoltages and undervoltages for three-phase 3-wire or 4-wire power supplies. Switch setting for 3-phase 3-wire or 3-phase 4-wire power


    Original
    PDF N148-E1-01 75-344-7119/Fax: EN61000-4-2

    K8AC-CT200

    Abstract: K8AC-CT200L omron k8ab-as2 IEC60947-3
    Text: Single-phase Current Relay K8AB-AS Ideal for current monitoring for industrial heaters and motors. • Monitor for overcurrents or undercurrents. • Manual resetting and automatically resetting supported by one Relay. • Startup lock and operating time can be set separately.


    Original
    PDF N142-E1-01 75-344-7119/Fax: K8AC-CT200 K8AC-CT200L omron k8ab-as2 IEC60947-3

    G7J-4A-P

    Abstract: E41643 LR35535 R99-04 T-345 coil IEC947-4-1
    Text: Electromechanical Relays Power Relay G7J A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor • Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads. • No contact chattering for momentary voltage drops up to 50%


    Original
    PDF UL94V-0-qualifying) AMP170333-1 AMP170334-1 AMP170335-1 AMP172076-1: AMP172076-4: AMP172076-5: AMP172076-6: J088-E1-03 G7J-4A-P E41643 LR35535 R99-04 T-345 coil IEC947-4-1

    ANSI37

    Abstract: No abstract text available
    Text: Motor Controllers DMPUC, DIN-Rail Motor Protection Unit • Controlling motor operation • Motor thermal protection • Phase sequence, phase loss, unbalance, locked rotor, stall, earth fault and earth leakage protection • Alarm set-points adjustable by the user


    Original
    PDF

    HOW TO CONVERT DC CURRENT TO AC CURRENT 50 HZ

    Abstract: current splitter Variable AC voltage AutoTransformer sv 120 115 relays SDV-SH30
    Text: Single-phase Voltage Relay K8AB-VS CSM_K8AB-VS_DS_E_3_1 Ideal for voltage monitoring for industrial facilities and equipment. • Monitor for overvoltages or undervoltages. • Manual resetting and automatically resetting supported by one Relay. • One SPDT output relay, 6 A at 250 VAC resistive load .


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Single-phase Voltage Relay K8AB-VW Ideal for voltage monitoring for industrial facilities and equipment. • Monitor for overvoltages and undervoltages simultaneously. Separate settings and outputs supported for overvoltages and undervoltages. • Manual resetting and automatically resetting supported by one


    Original
    PDF N144-E1-02

    IEC60255

    Abstract: relay miniature 110 vdc NEC Tokin signal relay tokin TOKIN 5 LR46266 NEC Tokin relay medical application of ultrasonic waves NEC RELAY
    Text: DATA SHEET MINIATURE SIGNAL RELAY EE2 SERIES Compact and lightweight, High breakdown voltage, Surface mounting type DESCRIPTION The EE2 series surface-mounting type sustaining high-performance of NEC TOKIN EC2 series. FEATURES Compact and light weight 2 form c contact arrangement


    Original
    PDF DE0202 IEC60255 relay miniature 110 vdc NEC Tokin signal relay tokin TOKIN 5 LR46266 NEC Tokin relay medical application of ultrasonic waves NEC RELAY

    E41643

    Abstract: No abstract text available
    Text: PCB Relay G5RL AC A Single-pole, 16-A Power Relay with AC Coil • 29.0 x 12.7 × 15.7 mm (L × W × H) Low profile: 15.7 mm in height ■ Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm


    Original
    PDF K129-E1-02 E41643

    E41643

    Abstract: LR35535 R99-04 IEC947-4-1 5381UG
    Text: Power Relay G7J CSM_G7J_DS_E_2_1 A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor • Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads. • No contact chattering for momentary voltage drops up to 50%


    Original
    PDF UL94V-0-qualifying) E41643 LR35535 R99-04 IEC947-4-1 5381UG

    K8AB

    Abstract: EN61000-4-2
    Text: Single-phase Voltage Relay K8AB-VS Ideal for voltage monitoring for industrial facilities and equipment. • Monitor for overvoltages or undervoltages. • Manual resetting and automatically resetting supported by one Relay. • One SPDT output relay, 6 A at 250 VAC resistive load .


    Original
    PDF N143-E1-01 75-344-7119/Fax: K8AB EN61000-4-2

    tokin 108

    Abstract: ee2-3nkx
    Text: DATA SHEET MINIATURE SIGNAL RELAY EE2 SERIES Compact and lightweight, High breakdown voltage, Surface mounting type DESCRIPTION The EE2 series surface-mounting type sustaining high-performance of NEC TOKIN EC2 series. FEATURES Compact and light weight 2 form c contact arrangement


    Original
    PDF

    N146-E1-01

    Abstract: AUTOMATIC PHASE SELECTOR using relay EN61000-4-2 3-phase monitoring relays circuit diagram IEC60947-1
    Text: Three-phase Phase-sequence Phase-loss Relay K8AB-PM Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. • Monitor overvoltages, undervoltages, phase sequence, and phase loss for three-phase 3-wire or 4-wire power supplies with


    Original
    PDF N146-E1-01 75-344-7119/Fax: N146-E1-01 AUTOMATIC PHASE SELECTOR using relay EN61000-4-2 3-phase monitoring relays circuit diagram IEC60947-1

    Untitled

    Abstract: No abstract text available
    Text: New Product Single-phase Current Relay K8AB-AS Ideal for current monitoring for industrial facilities and equipment. • Monitor for overcurrents or undercurrents. • Manual resetting and automatically resetting supported by one Relay. • Startup lock and operating time can be set separately.


    Original
    PDF 2356-81-300/Fax: 847-843-7900/Fax: 6835-3011/Fax: 21-5037-2222/Fax: N142-E1-03

    EN61000-4-2

    Abstract: No abstract text available
    Text: Three-phase Voltage Relay K8AB-PW Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. • Monitor overvoltages and undervoltages for three-phase 3-wire or 4-wire power supplies. Switch setting for 3-phase 3-wire or 3-phase 4-wire power


    Original
    PDF N148-E1-01 75-344-7119/Fax: EN61000-4-2

    wiring diagram motor autotransformer

    Abstract: mm2 relay phase line, phase asymmetry AWG16 AWG18 wiring diagram of autotransformer for three phase
    Text: Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA CSM_K8AB-PA_DS_E_3_1 Ideal for 3-phase voltage asymmetry monitoring for industrial facilities and equipment. • Monitor voltage asymmetry, phase sequence, and phase loss for three-phase 3-wire or 4-wire power supplies with just one


    Original
    PDF

    K8AC-CT200L

    Abstract: transformer ct K8ACCT200L HOW TO CONVERT DC CURRENT TO AC CURRENT 50 HZ omron k8ab-as2 CT200 K8AC-CT200 AWG16 AWG18 autotransformer motor wiring diagram
    Text: Single-phase Current Relay K8AB-AS CSM_K8AB-AS_DS_E_5_1 Ideal for current monitoring for industrial facilities and equipment. • Monitor for overcurrents or undercurrents. • Manual resetting and automatically resetting supported by one Relay. • Startup lock and operating time can be set separately.


    Original
    PDF