Bosch CJ 840
Abstract: PD-53 burkert ac10 burkert EX-95 CE0102 CEO102 2129X 2043X bosch me 7.3.1
Text: Operating Instructions Bedienungsanleitung Instructions de Service PTB No. 00 ATEX 2129 X Device with II 2G/D EEx m and II 2G EEx em-approval Example: Type 6013 Geräte mit II 2G/D EEx m bzw. II 2G EEx em-Zulassung Beispiel: Type 6013 Appareils avec mode de protection
|
Original
|
94/9/EC
Ex-95
2043X
Bosch CJ 840
PD-53
burkert ac10
burkert
CE0102
CEO102
2129X
2043X
bosch me 7.3.1
|
PDF
|
Ex-83
Abstract: EX 83/2022x PTB ex-85/2040 working principle of encoder PTB Ex-83/3120 TRD-G DIN19234 Ex-85/2040 Ex-83/PTB Ex-83/3120 PTB Ex-83/2022
Text: Incremental Encoder Series TRD-G • Intrinsically safe: EEx ia IIC T6 and EEx ib IIC T6 · NAMUR Interface acc. to DIN 19234 · For addittional accessories refer to Pepperl+Fuchs catalogue "Ex-i-Interface" · 1- or 2 channels Pulses per revolution: TRD-G . N1/N2
|
Original
|
Ex-83/2022
Ex-85/2040
Ex-83
EX 83/2022x
PTB ex-85/2040
working principle of encoder
PTB Ex-83/3120
TRD-G
DIN19234
Ex-85/2040
Ex-83/PTB Ex-83/3120
PTB Ex-83/2022
|
PDF
|
kfd2-stc1-ex1
Abstract: kfd2 fisher-rosemount Ex-94 namur NE 93 namur NE 21 STT01 ST-T01 bailey transmitter abb SMART temperature Transmitter
Text: SMART Transmitter Power Supplies Hazardous area KFD2-ST*1-Ex1* Input EEx ia IIC SMART transmitter SMART communicator 1-channel Input EEx ia IIC; U0 = 28V 24 V DC nominal supply voltage SMART capable up to 12 kHz -1 dB EMC acc. to NAMUR NE 21 1+ 3- 1+ + -
|
Original
|
|
PDF
|
50mA fuse
Abstract: 4-20ma to 2-10v converter Voltage to Current Converter circuit 4-20mA kfd2-cd-ex1.32 kfd2
Text: P R O C E S S A U T O M A T I O N - Single Channel Hazardous area TIBs for Current / Voltage KFD2-CD-Ex1.32 Output EEx ia IIC - Output EEx ia IIC Class I, Div 1, Groups A-G ? J - DC 24 V Nominal Power Supply - Voltage / Current or Current / Voltage Conversion
|
Original
|
0/4-20mA
0/2-10V
50mA fuse
4-20ma to 2-10v converter
Voltage to Current Converter circuit 4-20mA
kfd2-cd-ex1.32
kfd2
|
PDF
|
038340
Abstract: 038356 KEMA94Y7176U H07V-K 455 EW 161001
Text: Feed-through terminals EEx e Terminals/Accessories Design General information, see page 3/2. Standard Z-series terminals for hazardous areas are certified with the increased-safety type of protection“e”and explosion group II. Z-series terminals are made of
|
Original
|
|
PDF
|
ABB katharometer 6539960
Abstract: BAS 98 ATEX 6539960 AK104 BAS 01 ATEX 1042 ATEX 7041 zener barrier AK102 ABB pressure regulator Hydrogen purity
Text: Data Sheet SS/AK100 Issue 9 ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators AK100 Series ATEX compliant – intrinsically safe to II 1 G CENELEC EEx ia IIC T4 Safety – early warning of hazardous hydrogen/air mixtures Cost savings
|
Original
|
SS/AK100
AK100
AK101
AK102
AK102
ABB katharometer 6539960
BAS 98 ATEX
6539960
AK104
BAS 01 ATEX 1042
ATEX 7041
zener barrier
ABB pressure regulator
Hydrogen purity
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Sealed Double Break Switches Series 83 139 - IP 67 - Explosion Proof EEX d IIC T6 Types General specifications Layout Components 83 139 0 - 1- 5 Material - Case : polyester - Contacts : silver - Membrane : nitrile on 83 139 0 - silicone on 83 139 1 - 2 - 5
|
Original
|
|
PDF
|
OPI110
Abstract: OPI-110 OPI110D
Text: OPI-110 Series Optically Coupled Isolators BASEEFA and ATEX CERTIFIED BASEEFA Certified BAS No. Ex 95C2096U EEx ia IIC The OPI-110, A/B/C and D are a family of optically coupled isolators, each consisting of a infrared light emitting diode, coupled to an NPN silicon phototransistor sealed in an
|
Original
|
OPI-110
95C2096U
OPI-110,
EN50020
EN50014
01ATEX1278U
94/9/EC
OPI110
OPI110D
|
PDF
|
ABB katharometer 6539960
Abstract: 6539960 42342 4234 250VA ATEX7041 fuse LINK 1A 350 V AC 4234000
Text: Data Sheet Katharometer Power Supply Units SS/4234_2 Series 4234-500 & 4234-600 Constant-current DC supply – for use with the ABB range of Katharometers Certified intrinsically safe option – ATEX II (1)G CENELEC [EEx ia] IIC Tamb. –20 to 55°C
|
Original
|
SS/4234
4234/50X)
SS/4234
ABB katharometer 6539960
6539960
42342
4234
250VA
ATEX7041
fuse LINK 1A 350 V AC
4234000
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Extract from the online catalog PT 2XEX I -BE Order No.: 2839279 Base element for protective plug PT with protective circuit for two 2core floating EEx ia signal circuits. Mounting on NS 35/7.5 and NS
|
Original
|
TT-2009)
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Extract from the online catalog TT-ST-M-EX I -24DC Order No.: 2859424 Modular spring-cage terminal block with integrated three-stage surge protection for a floating EEx ia signal circuit, separate ground
|
Original
|
-24DC
TT-2009)
-24DC
|
PDF
|
Untitled
Abstract: No abstract text available
Text: lumiglas ® lumiglas Lumiglas Luminaire Series USL 05-EX EEx d II C T3 . T6 ISO 9001 - for use with sightglass fittings DATA SHEET 02-0200 08/02 Application: This super-compact luminaire can be used for integral light/sight port single flange version or separate light and sight ports (dual
|
Original
|
05-EX
05-EX,
|
PDF
|
4500mm
Abstract: PT 1 2 24DC ST
Text: Extract from the online catalog PT 2XEX I -24DC-ST Order No.: 2838225 Protective plug PT with protective circuit for two 2-core floating EEx ia signal circuits. Nominal voltage: 24 V DC
|
Original
|
-24DC-ST
TT-2009)
-24DC-ST
4500mm
PT 1 2 24DC ST
|
PDF
|
OPI110
Abstract: OPI-110 10KV DIODE EN50014 01ATEX1278U OPI110B
Text: OPI-110 Series Optically Coupled Isolators BASEEFA and ATEX CERTIFIED BASEEFA Certified BAS No. Ex 95C2096U EEx ia IIC The OPI-110, A/B/C and D are a family of optically coupled isolators, each consisting of a infrared light emitting diode, coupled to an NPN silicon phototransistor sealed in an
|
Original
|
OPI-110
95C2096U
OPI-110,
EN50020
EN50014
01ATEX1278U
94/9/EC
OPI110
10KV DIODE
01ATEX1278U
OPI110B
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Extract from the online catalog PT 2XEX I -BE Order No.: 2839279 Base element for protective plug PT with protective circuit for two 2core floating EEx ia signal circuits. Mounting on NS 35/7.5 and NS
|
Original
|
TT-2009)
|
PDF
|
EN50281
Abstract: BS5345 BS5501 R type thermocouple zirconia oxygen 10VA EN60584 pt 100 temperature probe abb abb pt pressure transmitter Zirconia Oxygen Probe
Text: Data Sheet SS/EXFG/GP Hazardous Area Zirconia Oxygen Systems Issue 9 EXFG & EXGP Hazardous area certification – ATEX II 2G EEx d IIB T3 T amb -20° to +50°C In situ probe for high speed measuring of excess oxygen – continuous uninterrupted on-line measurement
|
Original
|
|
PDF
|
kfd2-eb2
Abstract: kfd2-cd-ex1.32 namur NE 93 kfd2 DIN 50014 ATEX 014 KFD2-CD valve positioners 0/kfd2-cd-ex1.32
Text: KFD2-CD-Ex1.32 Current/voltage repeater Connection • • • • • • • • • 1-channel Output EEx ia IIC 24 V DC supply voltage Device installation permissible in zone 2 Conversion of current/voltage or voltage/current Elevation/Suppression of the "life
|
Original
|
PR-03
UPR-03
kfd2-eb2
kfd2-cd-ex1.32
namur NE 93
kfd2
DIN 50014
ATEX 014
KFD2-CD
valve positioners
0/kfd2-cd-ex1.32
|
PDF
|
LOM 02 ATEX 2037
Abstract: cooper CERTIFICATE LOM 02 ATEX 2037 LOM 02 ATEX 2037 certificate atex 2037 cooper CERTIFICATE c30 diode diode C30 LOM 02 ATEX 2037 X EN60079-0 c30 datasheet
Text: 56-57.qxp 8/11/2010 12:51 PM Page 57 Condulet Conduit Outlet Boxes With Covers Ex II 2 G EEx d IIC T6 Ex II 2 D IP66 T 85ºC Zone 1, 2, 21 and 22 3F for IEC Applications C30 Series C31 Series 3F Applications: C30 and C31 series conduit outlet boxes are installed in electrical systems within
|
Original
|
|
PDF
|
wkn 16 sl
Abstract: B11638U B1163 14-4AWG eex Series
Text: selos selos Ground blocks type WK/WKN . SL/U enclosed design enclosed design WK 4 SL/U EN 60 947-7-2/DIN VDE 0611 T3 UL -ratings field/factory wiring CSA ratings Width Wire strip length Approvals Ground block with U-foot Color: yellow/green EEx e ground block with U-foot1
|
Original
|
947-7-2/DIN
wkn 16 sl
B11638U
B1163
14-4AWG
eex Series
|
PDF
|
PTB 00 ATEX 3108
Abstract: GHG 731 PTB 99 ATEX 1044 ceag ghg atex GHG 744 CEAG ghg 731 ghg 745 CEAG PTB 99 ATEX ceag ghg
Text: Technical data Ex-e junction boxes eAZK 96 1 Marking to 94/9/EC Type of protection EC-Type Examination Certificate Enclosure material Degree of protection Rated voltage Rated current II 2 G/ II 2 D* EEx e II T6 PTB 00 ATEX 3108 Extremely tough polyamide IP 66 to EN 60529
|
Original
|
94/9/EC
PTB 00 ATEX 3108
GHG 731
PTB 99 ATEX 1044
ceag ghg atex
GHG 744
CEAG ghg 731
ghg 745
CEAG
PTB 99 ATEX
ceag ghg
|
PDF
|
GHG 744
Abstract: jb 5531 marshalling box ghg 745 744 745 510 terminal EEx "e" II - T6 ghg junction box GHG 44 ATEX BOX in 746
Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0159-2 Name: 6F-159 100: DATE: JAN 19 2006 Time: 5:06:20 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 UL/cUL Listed EEx de IIC, T6, Zones 1 and 2 Class I, Division 2, Groups A, B, C, D
|
Original
|
SYS19:
CRMAIN06-0159-2
6F-159
66008com
GHG 744
jb 5531
marshalling box
ghg 745
744 745 510
terminal EEx "e" II - T6
ghg junction box
GHG 44
ATEX BOX
in 746
|
PDF
|
LOM 03 ATEX 2108
Abstract: electrical sealing Compound cooper CERTIFICATE CROUSE-HINDS EYS fittings eex Series EYS 00 atex PRESSURE LIGHT atex nipples
Text: 148-149.qxp 8/11/2010 6F 11:00 AM Page 148 Conduit Sealing Fittings Ex II 2 G EEx d IIC Zone 1 and 2 6F for IEC Applications Applications: EYS and EZS sealing fittings: • Restrict the passage of gases, vapors or flames from one portion of the electrical installation to another at atmospheric pressure and
|
Original
|
|
PDF
|
XLVS11212061
Abstract: XLHS14030201 XLHZTMP7676 XLHS13030151 XLHS14040201 XLHS14030151 XLVS13024081 XLVS11616081 XLVS11612081 XLHS13020151
Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0141-9 Name: 6F-141 100: DATE: JAN 19 2006 Time: 5:04:56 PM Operator: RB COLOR: CMYK TCP: 15001 ATEX II 2 GD Eex e II T6 Certified IP66 to EN60529 cULus to UL50 C22.2 no. 94-M91 Type 3S and 4X Ex-CELL Enclosures
|
Original
|
SYS19:
CRMAIN06-0141-9
6F-141
EN60529
94-M91
XLHS16040151
XLHS16040201
XLHS16050151
XLHS16050201
XLHS16060151
XLVS11212061
XLHS14030201
XLHZTMP7676
XLHS13030151
XLHS14040201
XLHS14030151
XLVS13024081
XLVS11616081
XLVS11612081
XLHS13020151
|
PDF
|
Untitled
Abstract: No abstract text available
Text: R E L I A B L E C A P A C I T O R S CO 7^55^2 SÔD 3> 0000075 -Ms-yr-os The E2T, EEX and ETX series of METALLIZED POLYESTER capacitors are made of extended foil, non-inductive construction. Each case is composed of a minimum of two and one-half wraps of polyester tape with each end
|
OCR Scan
|
QD007S