Untitled
Abstract: No abstract text available
Text: Inductive sensor with selective targeting BI5NF-EM18HE-AN6X2-H1141 • Threaded barrel, M18 x 1 ■ Long version ■ Stainless steel, 1.4301 ■ Duroplast front cap, temperature and impact resistant ■ Detects non-ferromagnetic metals only ■ DC 3-wire, 10…30 VDC
|
Original
|
BI5NF-EM18HE-AN6X2-H1141
insula45102
BST-18B
MW-18
BSS-18
2013-07-13T05
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Inductive sensor NI12U-MT18H-AP6X-H1141 • Threaded barrel, M18 x 1 ■ Brass, PTFE-coated ■ Duroplast front cap, resistant to thermal and mechanical loads ■ Factor 1 for all metals ■ Magnetic field immune ■ Extended temperature range ■ High switching frequency
|
Original
|
NI12U-MT18H-AP6X-H1141
BSS-18
2013-07-13T06
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Inductive sensor BI5U-MT18H-AN6X-H1141 • Threaded barrel, M18 x 1 ■ Brass, PTFE-coated ■ Duroplast front cap, resistant to thermal and mechanical loads ■ Factor 1 for all metals ■ Magnetic field immune ■ Extended temperature range ■ High switching frequency
|
Original
|
BI5U-MT18H-AN6X-H1141
BSS-18
2013-07-13T06
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Inductive sensor BI10U-MT30H-AP6X-H1141 • Threaded barrel, M30 x 1.5 ■ Brass, PTFE-coated ■ Duroplast front cap, resistant to thermal and mechanical loads ■ Factor 1 for all metals ■ Magnetic field immune ■ Extended temperature range ■ High switching frequency
|
Original
|
BI10U-MT30H-AP6X-H1141
BSS-30
2013-07-13T06
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Inductive sensor with selective targeting BI3NF-EM12HE-AN6X2-H1141 • Threaded barrel, M12 x 1 ■ Stainless steel, 1.4301 ■ Duroplast front cap, temperature and impact resistant ■ Detects non-ferromagnetic metals only ■ DC 3-wire, 10…30 VDC ■ NO contact, NPN output
|
Original
|
BI3NF-EM12HE-AN6X2-H1141
QM-12
MW-12
BSS-12
2013-07-13T05
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Inductive sensor BI3U-MT12H-AP6X-H1141 • Threaded barrel, M12x1 ■ Brass, PTFE-coated ■ Duroplast front cap, resistant to thermal and mechanical loads ■ Factor 1 for all metals ■ Magnetic field immune ■ Extended temperature range ■ High switching frequency
|
Original
|
BI3U-MT12H-AP6X-H1141
M12x1
2013-07-13T05
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Inductive sensor with selective targeting BI3NF-EM12HE-AP6X2-H1141 • Threaded barrel, M12 x 1 ■ Stainless steel, 1.4301 ■ Duroplast front cap, temperature and impact resistant ■ Detects non-ferromagnetic metals only ■ DC 3-wire, 10…30 VDC ■ NO contact, PNP output
|
Original
|
BI3NF-EM12HE-AP6X2-H1141
QM-12
MW-12
BSS-12
2013-07-13T05
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Subject to change without notice Edition Inductive Sensor uprox Bi10U-EM30H-AP6X-H1141 Threaded barrel, M30x1 Stainless steel Duroplast front cap, high mechnical 15 36/5 40 and thermical resistance Factor 1 for all metals 63 Degree of protection IP68
|
Original
|
Bi10U-EM30H-AP6X-H1141
M30x1
10-30VDC
M12x1
SKN/M30
QM-30
BST-30B
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Inductive sensor NI8U-MT12H-AN6X-H1141 • Threaded barrel, M12x1 ■ Brass, PTFE-coated ■ Duroplast front cap, resistant to thermal and mechanical loads ■ Factor 1 for all metals ■ Magnetic field immune ■ Extended temperature range ■ High switching frequency
|
Original
|
NI8U-MT12H-AN6X-H1141
M12x1
BSS-12
2013-07-13T06
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Inductive sensor NI8U-MT12H-AP6X-H1141 • Threaded barrel, M12x1 ■ Brass, PTFE-coated ■ Duroplast front cap, resistant to thermal and mechanical loads ■ Factor 1 for all metals ■ Magnetic field immune ■ Extended temperature range ■ High switching frequency
|
Original
|
NI8U-MT12H-AP6X-H1141
M12x1
BSS-12
2013-07-13T06
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Inductive sensor with selective targeting BI5NF-EM18HE-AP6X2-H1141 • Threaded barrel, M18 x 1 ■ Long version ■ Stainless steel, 1.4301 ■ Duroplast front cap, temperature and impact resistant ■ Detects non-ferromagnetic metals only ■ DC 3-wire, 10…30 VDC
|
Original
|
BI5NF-EM18HE-AP6X2-H1141
insula45102
BST-18B
MW-18
BSS-18
2013-07-13T05
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Inductive sensor BI3U-MT12H-AN6X-H1141 • Threaded barrel, M12x1 ■ Brass, PTFE-coated ■ Duroplast front cap, resistant to thermal and mechanical loads ■ Factor 1 for all metals ■ Magnetic field immune ■ Extended temperature range ■ High switching frequency
|
Original
|
BI3U-MT12H-AN6X-H1141
M12x1
BSS-12
2013-07-13T05
D-45472
|
PDF
|
duroplast CONNECTOR
Abstract: CA25 duroplast
Text: Subject to change without notice Edition Inductive sensor uprox Bi10U-CA25-AP6X2-H1141 Rectangular, height 25mm Sensor housing, GD-CuZn 12 25 40 32,5 Turnable connector 4 positions 25 18 16 M 12 x 1 25 58,5 Turnable sensing head (5 positions) Plastic, Duroplast
|
Original
|
Bi10U-CA25-AP6X2-H1141
10-30VDC
M12x1
duroplast CONNECTOR
CA25
duroplast
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Inductive sensor NI12U-MT18H-AN6X-H1141 • Threaded barrel, M18 x 1 ■ Brass, PTFE-coated ■ Duroplast front cap, resistant to thermal and mechanical loads ■ Factor 1 for all metals ■ Magnetic field immune ■ Extended temperature range ■ High switching frequency
|
Original
|
NI12U-MT18H-AN6X-H1141
BSS-18
2013-07-13T06
D-45472
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Inductive sensor BI10U-MT30H-AN6X-H1141 • Threaded barrel, M30 x 1.5 ■ Brass, PTFE-coated ■ Duroplast front cap, resistant to thermal and mechanical loads ■ Factor 1 for all metals ■ Magnetic field immune ■ Extended temperature range ■ High switching frequency
|
Original
|
BI10U-MT30H-AN6X-H1141
BSS-30
2013-07-13T06
D-45472
|
PDF
|
pa66-gf30
Abstract: PA66-GF pa66-gf 30 PA66-GF 45
Text: Subject to change without notice Edition Inductive Sensor uprox Ni12U-EM18H-AP6X-H1141 Threaded barrel, M18x1 Stainless steel 10 36 52 9 24/4 M 12 x 1 Duroplast front cap, high mechanical and thermical resistance Factor 1 for all metals Degree of protection IP68
|
Original
|
Ni12U-EM18H-AP6X-H1141
M18x1
10-30VDC
M12x1
BST-18B
QM-18
PA66-GF
BSN18
pa66-gf30
PA66-GF
pa66-gf 30
PA66-GF 45
|
PDF
|
pa66-gf 30
Abstract: PA66-GF pa66-gf30 BSN18 PA66-GF 45 BST-18B PA66-GF 25 Bi5U-EM18H-AP6X-H1141 QM-18
Text: Subject to change without notice Edition Inductive Sensor uprox Bi5U-EM18H-AP6X-H1141 Threaded barrel, M18x1 Stainless steel Duroplast front cap, high mechanical and thermical resistance 36 52 24/4 9 M 12 x 1 Factor 1 for all metals Degree of protection IP68
|
Original
|
Bi5U-EM18H-AP6X-H1141
M18x1
10-30VDC
M12x1
BST-18B
QM-18
PA66-GF
BSN18
pa66-gf 30
PA66-GF
pa66-gf30
BSN18
PA66-GF 45
BST-18B
PA66-GF 25
Bi5U-EM18H-AP6X-H1141
QM-18
|
PDF
|
PBT-GF20
Abstract: PBT-GF20 CONNECTOR BI3U-EM12H-AP6X-H1141 M12X1 BS12 M12x1 connector
Text: Subject to change without notice Edition Inductive Sensor uprox Bi3U-EM12H-AP6X-H1141 Threaded barrel, M12x1 Stainless steel Duroplast front cap, high mechnaical and thermical resistance 36 52 17/4 9 M 12 x 1 Factor 1 for all metals Degree of protection IP68
|
Original
|
Bi3U-EM12H-AP6X-H1141
M12x1
10-30VDC
M12x1
SKN/M12
PBT-GF20
BST-12B
QM-12
PBT-GF20
PBT-GF20 CONNECTOR
BI3U-EM12H-AP6X-H1141
BS12
M12x1 connector
|
PDF
|
Bi20U-CA40-AP6X2-H1141
Abstract: BI20UCA40AP6X2H1141 CA40 duroplast CONNECTOR duroplast
Text: Subject to change without notice Edition Inductive sensor uprox Bi20U-CA40-AP6X2-H1141 Rectangular, height 40mm Turnable sensing head 5 positions LED 30 40 5,3 x 7,3 Plastic, duroplast 40 M 12 x 1 Factor 1 for all metals Magnetic field immune
|
Original
|
Bi20U-CA40-AP6X2-H1141
10-30VDC
M12x1
Bi20U-CA40-AP6X2-H1141
BI20UCA40AP6X2H1141
CA40
duroplast CONNECTOR
duroplast
|
PDF
|
PBT-GF20
Abstract: PBT-GF20 CONNECTOR PBT-GF20 2.2 BS12 duroplast
Text: Subject to change without notice Edition Inductive Sensor uprox Ni8U-EM12H-AP6X-H1141 Threaded barrel, M12x1 Stainless steel Duroplast front cap, high mechnai10 cal and thermical resistance 36 17/4 52 9 M 12 x 1 Factor 1 for all metals Degree of protection IP68
|
Original
|
Ni8U-EM12H-AP6X-H1141
M12x1
10-30VDC
M12x1
SKN/M12
PBT-GF20
BST-12B
QM-12
PBT-GF20
PBT-GF20 CONNECTOR
PBT-GF20 2.2
BS12
duroplast
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Subject to change without notice Edition Inductive Sensor uprox Ni20U-EM30H-AP6X-H1141 Threaded barrel, M30x1 Stainless steel Duroplast front cap, high mechnical 15 and thermical resistance 46 36/5 62 9 M 12 x 1 Factor 1 for all metals Degree of protection IP68
|
Original
|
Ni20U-EM30H-AP6X-H1141
M30x1
10-30VDC
M12x1
SKN/M30
QM-30
BST-30B
|
PDF
|
duroplast
Abstract: No abstract text available
Text: Heavy-Duty Connectors Technical Information - Materials Housings: Housings are made of aluminum alloys, brass, or sea water resistant bronze. Special materials are available. Contact inserts and insulation bodies: Standard Series 207, 208,and 209 Series 308, 309 and 310
|
Original
|
D-84453
duroplast
|
PDF
|
M12EL-GSH40B-S04G-M01
Abstract: BES-M18EL-pSC80B-S04G BES-M12EL-PSC40B-S04G BES M12EL-GSH40B-S04G-M01 M12EL-GSH20B-S04G-M01 BES-M12EL-USV40B-S21G-004 proximax MICRO C04 BES-M12EL-PSC40B-BP03 BES-M18EL-PSC80B-BP03
Text: Inductive Sensors AC/DC M12, M18 sn 4 mm, 8 mm PROXIMAX Housing size Mounting Rated operating distance sn Maximum Performance Maximum Durability In today's demanding automation environment inductive proximity sensors are a necessity. Inductive sensors must be
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Heavy-Duty Connectors OdU Section 5 Technical Information fo r the User °c t ru u . CD CL CD “O CD ZD L T\ CO CD 5 10 20 30 40 Test current ► 50 60 A Table o f Contents Page Environmental Protection IP in accordance with DIN 40 050 Insulation Groups / Nominal Voltage / Test Voltage
|
OCR Scan
|
D-84453
|
PDF
|