C024
Abstract: No abstract text available
Text: Current and Voltage Controls 1-Phase AC/DC Over Current Type EII • AC/DC over current metering open circuit relay • Current measuring through internal shunt • 3 position rotary switch for selection of measuring range • Measuring ranges: 0.4 mA - 10 A
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Current and Voltage Controls 1-Phase AC/DC Under Current Type EID • AC/DC under current metering closed circuit relay • Current measuring through internal shunt • 3 position rotary switch for selection of measuring range • Measuring ranges: 0.4 mA - 10 A
|
Original
|
|
PDF
|
PE Relay
Abstract: spdt 10A relay C2305A C024 60038
Text: Current and Voltage Controls 1-Phase AC/DC Over Current Type EII • AC/DC over current metering open circuit relay • Current measuring through internal shunt • 3 position rotary switch for selection of measuring range • Measuring ranges: 0.4 mA - 10 A
|
Original
|
|
PDF
|
230 volt ac overvoltage protection
Abstract: C1155A C11510A C2305A C024
Text: Current and Voltage Controls 1-Phase AC/DC Under Current Type EID • AC/DC under current metering closed circuit relay • Current measuring through internal shunt • 3 position rotary switch for selection of measuring range • Measuring ranges: 0.4 mA - 10 A
|
Original
|
|
PDF
|
EL50P1
Abstract: ES1000C ES300C Hall Effect Current Sensors ABB ES2000C MP25P1 VD1500-48 1SBT172000R9944 EL55P2 EL25P1
Text: Technical catalogue Current sensors Voltage sensors Current sensors Voltage sensors Contents Technologies Current measuring technology . 4 Voltage measuring technology . 8
|
Original
|
F-69685
C0202
EL50P1
ES1000C
ES300C
Hall Effect Current Sensors ABB
ES2000C
MP25P1
VD1500-48
1SBT172000R9944
EL55P2
EL25P1
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Current and Voltage Controls 1-Phase AC/DC Under Current Shunt Type EIC • AC/DC under current (closed circuit) metering relay • Measuring through external shunt • 3-position rotary switch for selection of measuring range • Measuring range: 10-50 mV, 12-60 mV, 30-150 mV or
|
Original
|
|
PDF
|
EIKC024
Abstract: PE Relay 0110 PE Relay
Text: Current and Voltage Controls 1-Phase AC/DC Over Current Shunt Type EIK • AC/DC over current (open circuit) metering relay • Measuring through external shunt • 3-position rotary switch for selection of measuring range • Measuring ranges: 10-50 mV, 12-60 mV, 30-150 mV or
|
Original
|
|
PDF
|
EICC230
Abstract: shunt release circuit diagram 3 position rotary switch
Text: Current and Voltage Controls 1-Phase AC/DC Under Current Shunt Type EIC • AC/DC under current (closed circuit) metering relay • Measuring through external shunt • 3-position rotary switch for selection of measuring range • Measuring range: 10-50 mV, 12-60 mV, 30-150 mV or
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Current and Voltage Controls 1-Phase AC/DC Over Current Shunt Type EIK • AC/DC over current (open circuit) metering relay • Measuring through external shunt • 3-position rotary switch for selection of measuring range • Measuring ranges: 10-50 mV, 12-60 mV, 30-150 mV or
|
Original
|
|
PDF
|
BS2757
Abstract: Critchley transformers IEC185 crompton PE401 PE601-1000/5 TH 2267 CRITCHLEY PE201-30/5 PE301-150/5
Text: PE Range Moulded Case Current Transformers 1 Moulded Case Measuring Current Transformers PE Range Moulded Case Current Transformers An extensive range of high quality current transformers offering comprehensive measuring class accuracies. The PE range provides
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: selos selos Current transformer disconnect terminals Current transformer circuits must always have a closed secondary circuit. This rule applies even when changing measuring instruments or electric meters and when carrying out reference measurements with external measuring
|
Original
|
|
PDF
|
741 LEM
Abstract: No abstract text available
Text: Voltage Transducer LV 100 For the electronic measurement of voltage: DC, AC, pulsed., with galvanic isolation between the primary circuit and the secondary circuit. Electrical data Features Primary nominal current rms Primary current, measuring range Measuring resistance
|
Original
|
28July2011/version
741 LEM
|
PDF
|
HIOKI 3287
Abstract: P1201A crest audio pro 8200
Text: 2014 Electrical Measuring Instruments General Catalog Recorders Data loggers Power Meters LCR Testers Battery Testers Current Probes Clamp Sensors Recorders / Data Loggers / Remote Measurement System / Component Measuring Instruments / Signal Sources / Safety Standards Measuring Instruments
|
Original
|
0001E52-3ZE-15K
HIOKI 3287
P1201A
crest audio pro 8200
|
PDF
|
AN1798
Abstract: APP1798 DS2761
Text: Maxim > App Notes > BATTERY MANAGEMENT Keywords: Frequency Undersampling in Coulomb-Counting: Measuring Current Flow in Battery Applications Dec 03, 2002 APPLICATION NOTE 1798 Frequency Undersampling in Coulomb-Counting: Measuring Current Flow in Battery Applications
|
Original
|
DS2761
com/an1798
DS2761:
AN1798,
APP1798,
Appnote1798,
AN1798
APP1798
|
PDF
|
|
en iec 60721-3-3
Abstract: No abstract text available
Text: G2II1 10A Current measurement in 1-phase mains Reinforced insulation of the measuring circuit Measured value transmitting via standard bus Modular monitoring system Measuring range between 100mA to 10A Width 22.5mm Industrial design Technical data 1. Functions
|
Original
|
100mA
RS485;
en iec 60721-3-3
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SICDS50V6 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Low power consumption Extended measuring range Insulated plastic case recognized according to UL 94-V0 IPN = 50A
|
Original
|
SICDS50V6
94-V0
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SIOLSV2 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Low power consumption Extended measuring range Isolation voltage 3000V IPN = 200…2000A,Vout=±4V Advantages Industrial applications
|
Original
|
SIOLS200V2
SIOLS400V2
SIOLS600V2
SIOLS800V2
SIOLS1000V2
SIOLS2000V2
|
PDF
|
en iec 60721-3-3
Abstract: digital potentiometer for AC Digital Potentiometer 10m
Text: G2II1 5A Current measurement in 1-phase mains Reinforced insulation of the measuring circuit Measured value transmitting via standard bus Modular monitoring system Measuring range between 20mA and 5A Width 22.5mm Industrial design Technical data 1. Functions
|
Original
|
RS485;
en iec 60721-3-3
digital potentiometer for AC
Digital Potentiometer 10m
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SICDS100V6 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Low power consumption Extended measuring range Insulated plastic case recognized according to UL 94-V0 IPN = 50A
|
Original
|
SICDS100V6
94-V0
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SIOY2CV2 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Compact design for PCB mounting Low power consumption Extended measuring range 3*IPN Insulated plastic case recognized
|
Original
|
94-V0
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SICF3SV2 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Low power consumption Extended measuring range Insulated plastic case recognized according to UL 94-V0 IPN = 100…300A
|
Original
|
94-V0
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SIOY3SV2 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Isolation voltage 3000 V Low power consumption Extended measuring range 3 *IPN Insulated plastic case recognized according
|
Original
|
94-V0
SIOY3S400V2
SIOY3S500V2
SIOY3S600V2
SIOY3S800V2
SIOY3S1000V2
SIOY3S1200V2
SIOY3S1500V2
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SIOT1SV2 Current Sensors Features Galvanic isolation between primary and secondary circuit Hall effect measuring principle Isolation voltage 3000V Low power consumption Extended measuring range 3*IPN Power supply from ±12V to ±15V
|
Original
|
SIOT1S10V2
SIOT1S15V2
SIOT1S20V2
SIOT1S25V2
SIOT1S30V2
|
PDF
|
MCR-SL-S-400-U
Abstract: phoenix contact 2813473
Text: Extract from the online catalog MCR-SL-S-400-U Order No.: 2813473 MCR current measuring transducer, for measuring sinusoidal and nonsinusoidal alternating currents, input current 0.400 A, output voltage
|
Original
|
MCR-SL-S-400-U
IF-2009)
MCR-SL-S-400-U
phoenix contact 2813473
|
PDF
|