Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CLASS II DIV II RELAYS Search Results

    CLASS II DIV II RELAYS Result Highlights (2)

    Part ECAD Model Manufacturer Description Download Buy
    AD6674BCPZRL7-750 Analog Devices 100/200MHz Dual Band Div Visit Analog Devices Buy
    AD6674BCPZ-750 Analog Devices 100/200MHz Dual Band Div Visit Analog Devices Buy

    CLASS II DIV II RELAYS Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    G0L53C3

    Abstract: G05-2A3F GOL2GR12 GOB4-G233C-N34-LED G02-GR12D GOB4-F233C GOM21-RM3C GOB3-R23C GO22 kz3C
    Text: C40 G SERIES • CONTROLS C U S T O M C O N T R O L PA N E L O P E R AT O R S I N T R O D U C T I O N Class I, Div. 1 & 2, Groups B,C,D Class I, Zones 1 & 2, Groups llB, llA Class II, Div. 1 & 2, Groups E,F,G Class Ill NEMA 3, 4, 4X, 7 B,C,D 9(E,F,G) See Area Classification Chart below


    Original
    PDF

    EFD34

    Abstract: DS161R Motor Control Center wiring diagram abb TFK catalog EX-88 WESTINGHOUSE motor life line westinghouse mcp breaker TFK 543 TC236
    Text: Industrial Control & Circuit Breakers Section C Innovative, intelligent NEC and IEC solutions safely and efficiently control power and protect circuits in explosive, wet, and corrosive environments worldwide. New Products in the Control Product Line Section


    Original
    PDF ACE20 EFD34 DS161R Motor Control Center wiring diagram abb TFK catalog EX-88 WESTINGHOUSE motor life line westinghouse mcp breaker TFK 543 TC236

    CROUSE-HINDS EPC

    Abstract: Cutler-Hammer 6-1-3 EPC813 Cutler-Hammer type m RELAY EPC871 100FB Cutler-Hammer 643 RELAY Cutler-Hammer contactor Cutler-Hammer current transformer integral 32 square d contactor
    Text: 1C EPC Combination Line Starters and Enclosures Applications: 1C • For across-the-line starting of polyphase AC induction motors • In locations which are hazardous due to the presence of flammable vapors, gases or highly combustible dusts • In damp, wet or corrosive locations


    Original
    PDF 15HMCP EPC871 30HMCP 15HMCP CROUSE-HINDS EPC Cutler-Hammer 6-1-3 EPC813 Cutler-Hammer type m RELAY EPC871 100FB Cutler-Hammer 643 RELAY Cutler-Hammer contactor Cutler-Hammer current transformer integral 32 square d contactor

    D2TW600

    Abstract: D2TW600VC class 1 div 2 relay ETW401 relay ul 1604 ETC232 nec reed relay door bell telephone relay RS-470
    Text: D2TW600 Telephone for Hazardous Areas Applications: These single-line, fully functional electronic telephones are used: • For communication in locations which may be hazardous due to the presence of flammable gases or vapors Division 2 , and/or combustible dusts or fibers


    Original
    PDF D2TW600 115VAC ETC232 ETW40 D2TW600 D2TW600VC class 1 div 2 relay ETW401 relay ul 1604 ETC232 nec reed relay door bell telephone relay RS-470

    HRC85

    Abstract: bimetal motor thermostat control bimetal fan control bimetal temperature control bimetal thermostat
    Text: Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 7CD, 9EFG, 12 HRC Thermostats with Honeywell Control Explosionproof Dust-Ignitionproof Raintight Wet Locations 3A Applications: HRC thermostats with Honeywell control


    Original
    PDF

    ETW401

    Abstract: 2 phone 1 line relay switch class 1 div 2 relay ETC232 telephone handset telephone handset cords ETW40 telephone relay switch keyboard circuit 301SC
    Text: 3A ETW Telephones Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications: ETW series telephones are used: • For communication in areas which may


    Original
    PDF 115VAC ETC232 ETW40 ETW401 2 phone 1 line relay switch class 1 div 2 relay ETC232 telephone handset telephone handset cords ETW40 telephone relay switch keyboard circuit 301SC

    SPACE HEATER

    Abstract: starter fvnr Cutler-Hammer 6-1-3 Transformer 200VA FVNR nema INDUCTION motor FVNR nema 1 2825 transformer Cutler-Hammer contactor allen bradley to Cutler-Hammer
    Text: EBMS Magnetic Line Starters and Enclosures Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 3R, 4‡, 7BCD, 9EFG, 12 Explosionproof Dust-Ignitionproof Raintight Wet Locations Watertight 2C Applications:


    Original
    PDF prote41 SPACE HEATER starter fvnr Cutler-Hammer 6-1-3 Transformer 200VA FVNR nema INDUCTION motor FVNR nema 1 2825 transformer Cutler-Hammer contactor allen bradley to Cutler-Hammer

    UL1203

    Abstract: Cutler-Hammer transformer 2 point starters Cutler-Hammer 6-1-3 Cutler-Hammer contactor FTPS100 SPACE HEATER FVNR nema 1 allen bradley to Cutler-Hammer FTPS200
    Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0343-1 Name: 2C-343 100: DATE: JAN 19 2006 Time: 5:18:14 PM Operator: RB EBMS Magnetic Line Starters and Enclosures Application: Spectrum EBM TM hinged cover motor control enclosures are used: ɀ For general motor control – indoors or


    Original
    PDF SYS19: CRMAIN06-0343-1 2C-343 desire00 66008com UL1203 Cutler-Hammer transformer 2 point starters Cutler-Hammer 6-1-3 Cutler-Hammer contactor FTPS100 SPACE HEATER FVNR nema 1 allen bradley to Cutler-Hammer FTPS200

    PTB 01 ATEX 1019 U

    Abstract: GUB03 GUB15151 GUB0110 GUB02 GUB01 GUB-MP03 GUB04 GUB01110 GUB-MP01
    Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0122-4 Name: 6F-122 6F DATE: JAN 19 2006 Time: 5:03:28 PM Operator: RB Junction Boxes Without Hubs* GUE, GUB series junction boxes are used in threaded rigid conduit systems in hazardous areas: ɀ to function as a splice box, pull box or


    Original
    PDF SYS19: CRMAIN06-0122-4 6F-122 GUB01 GUB03 66008com PTB 01 ATEX 1019 U GUB03 GUB15151 GUB0110 GUB02 GUB01 GUB-MP03 GUB04 GUB01110 GUB-MP01

    Untitled

    Abstract: No abstract text available
    Text: SELECTION GUIDE FOR OMEGA ZENER BARRIERS FOR INTRINSIC SAFETY MADE IN FM USA APPROVED OMEGA® SOLID STATE RELAYS AND ZENER BARRIERS FOR INTRINSIC SAFETY The maximum energy possible at the switch terminals of the OMEGA® Zener Barriers is far below the explosive point of the most


    Original
    PDF K-110

    PTB 01 ATEX 1019 U

    Abstract: NEC D 822 P gu 5.3 ATEX BOX GUB02 GUB01 GUB0110 CROUSE-HINDS EPC GUB01110 GUB03
    Text: 1E GUE, GUB Junction Boxes Applications: GUE, GUB series junction boxes are used in threaded rigid conduit systems in hazardous areas: • To function as a splice box, pull box or equipment and device enclosure • To house wiring • Indoors and outdoors


    Original
    PDF GUB01 GUB03 PTB 01 ATEX 1019 U NEC D 822 P gu 5.3 ATEX BOX GUB02 GUB01 GUB0110 CROUSE-HINDS EPC GUB01110 GUB03

    Cutler-Hammer HMCP

    Abstract: DS363R DS161R tfk 623 tfk 613 Cutler-Hammer contactor HMCP DS262R UL1203 allen bradley to Cutler-Hammer
    Text: EBMC Combination Line Starters and Enclosures Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 3R, 4‡, 7BCD, 9EFG, 12 Explosionproof Dust-Ignitionproof Raintight Wet Locations Watertight 1C Applications:


    Original
    PDF

    MP1410

    Abstract: CROUSE-HINDS EJB EJB241810 EJB060404-SA EJB080806-SA EJB161606 EJB241808 EJB242408 EJB362408 EJB-MP1812
    Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRTEST06-3128-0 Name: 6F-128 6F 100: DATE: JAN 19 2006 Time: 6:18:06 PM Operator: RB EJB Junction Boxes COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups B,C,D Cl. II, Div. 1, Groups E,F,G


    Original
    PDF SYS19: CRTEST06-3128-0 6F-128 oB181206 EJB181208 EJB241208 EJB241210 EJB241808 EJB241810 EJB242408 MP1410 CROUSE-HINDS EJB EJB060404-SA EJB080806-SA EJB161606 EJB362408 EJB-MP1812

    Cutler-Hammer HMCP

    Abstract: HMCP UL1203 Cutler-Hammer contactor allen bradley to Cutler-Hammer equivalent transistor TT 3034 DS363R Cutler-Hammer transformer TFK D 327 DS161R
    Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0327-2 Name: 1C-327 100: DATE: JAN 19 2006 Time: 5:18:00 PM Operator: RB EBMC Combination Line Starters and Enclosures COLOR: CMYK Cl. I, Div. 1 & 2, Groups B,C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G


    Original
    PDF SYS19: CRMAIN06-0327-2 1C-327 66008com Cutler-Hammer HMCP HMCP UL1203 Cutler-Hammer contactor allen bradley to Cutler-Hammer equivalent transistor TT 3034 DS363R Cutler-Hammer transformer TFK D 327 DS161R

    EPC TRANSFORMER

    Abstract: ESWP126 CROUSE-HINDS EPC EPC813 wiring ESWP126 S454V PILOT LIGHT Cutler-Hammer 6-1-3 EPC971 S219
    Text: EPC Magnetic Line Starters and Enclosures Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 7CD, 9EFG, 12 Applications: Standard Finishes: EPC magnetic line starters and enclosures are used: • For across-the-line starting of polyphase


    Original
    PDF EPC87 EPC813 EPC87----KIT EPC TRANSFORMER ESWP126 CROUSE-HINDS EPC EPC813 wiring ESWP126 S454V PILOT LIGHT Cutler-Hammer 6-1-3 EPC971 S219

    MP1410

    Abstract: EJB241808 EJB362408 EJB161606 EJB121206 EJB161608 CROUSE-HINDS EJB EJB100806 EJB121208 EJB242408
    Text: 1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*, 7, 9 Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications: EJB junction boxes are used in threaded


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: 440 / 450 Electronic Vibration Switches Datasheet OVERVIEW Metrix 440 and 450 electronic vibration switches provide economical, self-contained, single-channel vibration protection. The 440 switch is suitable for use in non-hazardous as well as Class I Div 2 hazardous areas. The 450 switch utilizes the same internal


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: BDI-FLX B URST DI S C S E N SOR SY STE M AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS The BDI-FLX™ Burst Disc Sensor System utilizes an electronic instrument which provides instantaneous notification of the bursting of a rupture disc using versatile interface cable options. When combined


    Original
    PDF 25mm-300mm) 25mm-100mm) 423/P/11, TCH1284

    Untitled

    Abstract: No abstract text available
    Text: Limit Switches and Machine Safety SENSING AND CONTROL Product Range Guide 1 For innovation that’s well apart, there’s only Honeywell Sensing and Control. With more than 50,000 products ranging from basic, limit, toggle, and pressure switches to position, speed, pressure,


    Original
    PDF 001033-11-ENâ

    class II div II relays

    Abstract: No abstract text available
    Text: Product Page HOME Page 1 of 1 ABOUT US KEY INDUSTRIES SERVED PRODUCTS & INFORMATION NEWS & EVENTS SALES & SUPPORT LOGIN GSXA42D Home : Products : Machine Safety » MICRO SWITCH Safety Switches » Electromechanical » GSX Search contacts Customer Service


    Original
    PDF GSXA42D id/140301/la id/148436 class II div II relays

    class II div II relays

    Abstract: No abstract text available
    Text: Product Page HOME Page 1 of 1 ABOUT US KEY INDUSTRIES SERVED PRODUCTS & INFORMATION NEWS & EVENTS SALES & SUPPORT LOGIN GSXA46C Home : Products : Machine Safety » MICRO SWITCH Safety Switches » Electromechanical » GSX Search contacts Customer Service


    Original
    PDF GSXA46C class II div II relays

    HART BELL 202

    Abstract: namur ne43 R137-1 bst+ekr+3000+manual
    Text: Product Data Sheet PS-00291, Rev. F April 2014 Micro Motion Series 3000 Transmitters and Controllers Micro Motion® Series 3000 electronics combine transmitter functions and PLC capabilities in one instrument. Series 3000 models feature MVD technology,


    Original
    PDF PS-00291, 2400S HART BELL 202 namur ne43 R137-1 bst+ekr+3000+manual

    inductive proximity sensor transistor schematic

    Abstract: schematic AC inductive proximity sensor INTRINSIC SAFE CIRCUIT SMB30S HP 9714 SMB30MM VOC sensor schematic DC inductive proximity sensor 27030 smicc-330
    Text: SMI30 Series Intrinsically Safe Sensors Rugged, NEMA 6P-plus sensors in 30 mm threaded PBT barrel housings • • • • • • • Designed for use with approved amplifiers and intrinsically safe barriers in explosive environments SMI30 Series sensors, shown with Intrinsic Safety Kit


    Original
    PDF SMI30 inductive proximity sensor transistor schematic schematic AC inductive proximity sensor INTRINSIC SAFE CIRCUIT SMB30S HP 9714 SMB30MM VOC sensor schematic DC inductive proximity sensor 27030 smicc-330

    Untitled

    Abstract: No abstract text available
    Text: Product Datasheet M800 Elite Speed Switch 4B Components Limited M800 Elite Speed Switch Monitors Rotating Machinery for Dangerous Underspeed Conditions APPLICATION The M800 Elite Speed Switch is designed to detect belt slip, belt underspeed, stop motion, low speed or zero speed on bucket


    Original
    PDF M8001V10C) M8002V10C) 100mA