E62806
Abstract: "Power Distribution block"
Text: Product Data Sheet 143X587 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 380 Amps, 600 Volts AC/DC See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (1) 500kcmil - #4 AWG
|
Original
|
143X587
500kcmil
CC143X
E62806
"Power Distribution block"
|
PDF
|
E62806
Abstract: No abstract text available
Text: Product Data Sheet 143X559 Replace “X” with 1, 2 or 3 for number of poles Power Splicer/Stud Block 310 Amps, 600 Volts AC/DC See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (1) 350kcmil - #6 AWG
|
Original
|
143X559
350kcmil
CC143X
E62806
|
PDF
|
E62806
Abstract: UL 1059 terminal block
Text: Product Data Sheet 143X554 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 310 Amps, 600 Volts AC/DC See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (1) 350 kcmil - #6 AWG
|
Original
|
143X554
CC143X
E62806
UL 1059 terminal block
|
PDF
|
E62806
Abstract: No abstract text available
Text: Product Data Sheet 143X123 Replace “X” with 1, 2 or 3 for number of poles Power Splicer Block 255 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 250 kcmil - #6 AWG Load Side: (1) 250 kcmil - #6 AWG Electrical Ratings: • 255A Copper wire, 205A Aluminum wire (Based on NEC Table 310-16, 75°C columns)
|
Original
|
143X123
250kcmil
CC143X
E62806
|
PDF
|
JJL36250
Abstract: E62806 JLL36250 JGL36250 jdl36250 143X555
Text: Product Data Sheet 143X555 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 350 Amps, 600 Volts AC/DC See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (2) 2/0 - #14 AWG
|
Original
|
143X555
CC143X
JJL36250
E62806
JLL36250
JGL36250
jdl36250
143X555
|
PDF
|
E62806
Abstract: No abstract text available
Text: Product Data Sheet 143X953 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 380 Amps, 600 Volts AC/DC See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (1) 500 kcmil - #4 AWG
|
Original
|
143X953
CC143X
E62806
|
PDF
|
E62806
Abstract: JJL36250 JLL36250
Text: Product Data Sheet 143X552 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 335 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 400 kcmil - #6 AWG Load Side: (4) #2 - #14 AWG See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals.
|
Original
|
143X552
CC143X
E62806
JJL36250
JLL36250
|
PDF
|
E62806
Abstract: No abstract text available
Text: Product Data Sheet 143X590 Replace “X” with 1, 2 or 3 for number of poles Power Splicer/Stud Block 175 Amps, 600 Volts AC/DC See tables below for Flexible stranded wire approvals. Wire Range: Line side: (1) 2/0 - #14 AWG Load Side: (1) 1/4 – 20 X 1 3/8” Stud
|
Original
|
143X590
CC143X
E62806
|
PDF
|
JDL36175
Abstract: JJL36175 JLL36175 JGL36175 E62806 JJL36250 JLL36250
Text: Product Data Sheet 143X955 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 350 Amps, 600 Volts AC/DC See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (2) 2/0 - #14 AWG
|
Original
|
143X955
CC143X
JDL36175
JJL36175
JLL36175
JGL36175
E62806
JJL36250
JLL36250
|
PDF
|
UL 1059 torque
Abstract: IEC 60947-7-1 E62806 20stud UL 1059 terminal block
Text: Product Data Sheet 143X561 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 230 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 3/8 – 16 X 1 3/8” Stud Load Side: (1) 1/4 – 20 X 1 3/8” Stud Electrical Ratings: • 230A Copper wire,
|
Original
|
143X561
E62806
LR19766
CC143X
UL 1059 torque
IEC 60947-7-1
E62806
20stud
UL 1059 terminal block
|
PDF
|
E62806
Abstract: 350kcmil
Text: Product Data Sheet 143X126 Replace “X” with 1, 2 or 3 for number of poles Power Splicer Block 310 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 350 kcmil - #6 AWG Load Side: (1) 350 kcmil - #6 AWG Electrical Ratings: • 310A Copper wire, 250A Aluminum wire (Based on NEC Table 310-16, 75°C columns)
|
Original
|
143X126
350kcmil
CC143X
E62806
|
PDF
|
E62806
Abstract: No abstract text available
Text: Product Data Sheet 143X124 Replace “X” with 1, 2 or 3 for number of poles Power Splicer Block 255 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 250 kcmil - #6 AWG Load Side: (1) 250 kcmil - #6 AWG Electrical Ratings: • 255A Copper wire (Based on NEC Table 310-16, 75°C columns)
|
Original
|
143X124
250kcmil
CC143X
E62806
|
PDF
|
copper bus bar torque
Abstract: IEC 60947-7-1 LR19766 E62806 143X563
Text: Product Data Sheet 143X563 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 230 Amps, 600 Volts AC/DC Wire Range: Line side: Listed ring lugs or bus bars Load Side: Listed ring lug or bus bars Electrical Ratings: • 230A • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)
|
Original
|
143X563
E62806
LR19766
CC143X
copper bus bar torque
IEC 60947-7-1
LR19766
E62806
143X563
|
PDF
|
140U-K3X3
Abstract: 140U-J6X3 allen bradley 140U-K6X3 140U-K6 E62806 JJL36250 JLL36250 143X553
Text: Product Data Sheet 143X553 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 335 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 400 kcmil - #6 AWG Load Side: (6) #2 - #14 AWG See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals.
|
Original
|
143X553
CC143X
140U-K3X3
140U-J6X3 allen bradley
140U-K6X3
140U-K6
E62806
JJL36250
JLL36250
143X553
|
PDF
|