    Catalog Datasheet MFG & Type Document Tags PDF

    E62806

    Abstract: "Power Distribution block"
    Text: Product Data Sheet 143X587 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 380 Amps, 600 Volts AC/DC See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (1) 500kcmil - #4 AWG


    Original
    143X587 500kcmil CC143X E62806 "Power Distribution block" PDF

    E62806

    Abstract: No abstract text available
    Text: Product Data Sheet 143X559 Replace “X” with 1, 2 or 3 for number of poles Power Splicer/Stud Block 310 Amps, 600 Volts AC/DC See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (1) 350kcmil - #6 AWG


    Original
    143X559 350kcmil CC143X E62806 PDF

    E62806

    Abstract: UL 1059 terminal block
    Text: Product Data Sheet 143X554 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 310 Amps, 600 Volts AC/DC See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (1) 350 kcmil - #6 AWG


    Original
    143X554 CC143X E62806 UL 1059 terminal block PDF

    E62806

    Abstract: No abstract text available
    Text: Product Data Sheet 143X123 Replace “X” with 1, 2 or 3 for number of poles Power Splicer Block 255 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 250 kcmil - #6 AWG Load Side: (1) 250 kcmil - #6 AWG Electrical Ratings: • 255A Copper wire, 205A Aluminum wire (Based on NEC Table 310-16, 75°C columns)


    Original
    143X123 250kcmil CC143X E62806 PDF

    JJL36250

    Abstract: E62806 JLL36250 JGL36250 jdl36250 143X555
    Text: Product Data Sheet 143X555 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 350 Amps, 600 Volts AC/DC See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (2) 2/0 - #14 AWG


    Original
    143X555 CC143X JJL36250 E62806 JLL36250 JGL36250 jdl36250 143X555 PDF

    E62806

    Abstract: No abstract text available
    Text: Product Data Sheet 143X953 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 380 Amps, 600 Volts AC/DC See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (1) 500 kcmil - #4 AWG


    Original
    143X953 CC143X E62806 PDF

    E62806

    Abstract: JJL36250 JLL36250
    Text: Product Data Sheet 143X552 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 335 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 400 kcmil - #6 AWG Load Side: (4) #2 - #14 AWG See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals.


    Original
    143X552 CC143X E62806 JJL36250 JLL36250 PDF

    E62806

    Abstract: No abstract text available
    Text: Product Data Sheet 143X590 Replace “X” with 1, 2 or 3 for number of poles Power Splicer/Stud Block 175 Amps, 600 Volts AC/DC See tables below for Flexible stranded wire approvals. Wire Range: Line side: (1) 2/0 - #14 AWG Load Side: (1) 1/4 – 20 X 1 3/8” Stud


    Original
    143X590 CC143X E62806 PDF

    JDL36175

    Abstract: JJL36175 JLL36175 JGL36175 E62806 JJL36250 JLL36250
    Text: Product Data Sheet 143X955 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 350 Amps, 600 Volts AC/DC See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (2) 2/0 - #14 AWG


    Original
    143X955 CC143X JDL36175 JJL36175 JLL36175 JGL36175 E62806 JJL36250 JLL36250 PDF

    UL 1059 torque

    Abstract: IEC 60947-7-1 E62806 20stud UL 1059 terminal block
    Text: Product Data Sheet 143X561 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 230 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 3/8 – 16 X 1 3/8” Stud Load Side: (1) 1/4 – 20 X 1 3/8” Stud Electrical Ratings: • 230A Copper wire,


    Original
    143X561 E62806 LR19766 CC143X UL 1059 torque IEC 60947-7-1 E62806 20stud UL 1059 terminal block PDF

    E62806

    Abstract: 350kcmil
    Text: Product Data Sheet 143X126 Replace “X” with 1, 2 or 3 for number of poles Power Splicer Block 310 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 350 kcmil - #6 AWG Load Side: (1) 350 kcmil - #6 AWG Electrical Ratings: • 310A Copper wire, 250A Aluminum wire (Based on NEC Table 310-16, 75°C columns)


    Original
    143X126 350kcmil CC143X E62806 PDF

    E62806

    Abstract: No abstract text available
    Text: Product Data Sheet 143X124 Replace “X” with 1, 2 or 3 for number of poles Power Splicer Block 255 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 250 kcmil - #6 AWG Load Side: (1) 250 kcmil - #6 AWG Electrical Ratings: • 255A Copper wire (Based on NEC Table 310-16, 75°C columns)


    Original
    143X124 250kcmil CC143X E62806 PDF

    copper bus bar torque

    Abstract: IEC 60947-7-1 LR19766 E62806 143X563
    Text: Product Data Sheet 143X563 Replace “X” with 1, 2 or 3 for number of poles Power Stud Block 230 Amps, 600 Volts AC/DC Wire Range: Line side: Listed ring lugs or bus bars Load Side: Listed ring lug or bus bars Electrical Ratings: • 230A • 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial)


    Original
    143X563 E62806 LR19766 CC143X copper bus bar torque IEC 60947-7-1 LR19766 E62806 143X563 PDF

    140U-K3X3

    Abstract: 140U-J6X3 allen bradley 140U-K6X3 140U-K6 E62806 JJL36250 JLL36250 143X553
    Text: Product Data Sheet 143X553 Replace “X” with 1, 2 or 3 for number of poles Power Distribution Block 335 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 400 kcmil - #6 AWG Load Side: (6) #2 - #14 AWG See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals.


    Original
    143X553 CC143X 140U-K3X3 140U-J6X3 allen bradley 140U-K6X3 140U-K6 E62806 JJL36250 JLL36250 143X553 PDF