Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CAV414 Search Results

    CAV414 Datasheets (2)

    Part ECAD Model Manufacturer Description Curated Type PDF
    CAV414 Analog Microelectronics Converter IC for Capacitive Signals Original PDF
    CAV414 Analog Microelectronics Converter IC for Capacitive Signals with voltage output CAV414 Original PDF

    CAV414 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    CAV444

    Abstract: D/A Wandler cav414 CAV424 formel nf MESS
    Text: CAV444 – Ein Kapazitäts/Spannungswandler-IC mit linearer Übertragungskennlinie Analog Microelectronics stellt in Ergänzung zu den bestehenden Kapazizäts/SpannungswandlerICs CAV414 und CAV424 das neue IC vom Typ CAV444 [1] vor. Hierbei handelt es sich um ein


    Original
    PDF CAV444 CAV414 CAV424 CAV444: CAV424: CAV414: CAV444 D/A Wandler formel nf MESS

    CAV414

    Abstract: DIL16 rcosc SO16N
    Text: Converter IC for Capacitive Signals CAV414 FEATURES GENERAL DESCRIPTION • Wide Supply Voltage Range: 6.35V • Wide Operating Temperature Range: –40°C.+85°C • High Detection Sensitivity of Relative Capacitive Changes: 5% – 100% • Detection Frequency up to 2kHz


    Original
    PDF CAV414 5/10V, CAV414 DIL16 rcosc SO16N

    CAV414

    Abstract: AM-422 nf schaltungen AM422 CAN404 namur output
    Text: Schnittstellen–ASICs für die kapazitive Meßtechnik CAN404 und CAV414 Der Druck ist neben der Temperatur eine der wichtigsten physikalischen Größen in der Prozeßmeßtechnik. Entsprechend groß ist die Vielfalt der verwendeten Sensorprinzipien. Neben den piezoresistiven Systemen findet man auch solche, die z.B. nach dem induktiven oder kapazitiven Prinzip


    Original
    PDF CAN404 CAV414 de/german/products/cav414 CAV414 AM-422 nf schaltungen AM422 namur output

    CAV414

    Abstract: DIL16
    Text: Converter IC for Capacitive Signals CAV414 FEATURES GENERAL DESCRIPTION • Wide Supply Voltage Range: 6.35V • Wide Operating Temperature Range: –40°C.+85°C • High Detection Sensitivity of Relative Capacitive Changes: 5% – 100% • Detection Frequency up to 2kHz


    Original
    PDF CAV414 5/10V, CAV414 DIL16

    AM402

    Abstract: ANALOGE cav414 AM422 AN1003 AN1004 PR1007 cp2a
    Text: Digitale Korrektur kapazitiver Signale mit Hilfe des Frame–ASICs CAV414 Messungen sind immer fehlerbehaftet und müssen mit geeigneten Methoden so korrigiert werden, daß die gewünschten Fehlergrenzen eingehalten werden können. Eine moderne Methode ist, mit Hilfe von Korrekturalgorithmen, die durch einen Prozessor ausgeführt


    Original
    PDF CAV414 CAV414 PR1007 CAV414: AN1003 AM402 20mA-Anwendung: ANALOGE AM422 AN1003 AN1004 PR1007 cp2a

    diode r2c

    Abstract: R2C TRANSISTOR 200K trimmer bd139 application note BD139 AM402 equivalent diode for R2C BD139 TRANSISTOR CAV414 1N4002 diode download datasheet
    Text: APPLICATION NOTE CAV414AM402 Description Analog Microelectronics GmbH AMG developed a breadboard that allows tests of the CAV414 in conjunction with the AM402 (current transmitter IC) in different configurations, e.g. with different capacitive sensors. The breadboard offers an independent adjustment of the output voltage


    Original
    PDF CAV414 AM402 CAV414 5/10V) CAV414/AM402. 100nF CAV414) 220nF diode r2c R2C TRANSISTOR 200K trimmer bd139 application note BD139 AM402 equivalent diode for R2C BD139 TRANSISTOR 1N4002 diode download datasheet

    water level sensor schematic diagram

    Abstract: capacitive sensor for water level measurement schematic inductive sensor capacitive level sensor circuit drawing CAV414 capacitive level sensor circuit diagram water level sensor circuit schematic level water namur standard AM-422
    Text: Interface ICs for Capacitive Measurement Technology CAN404 and CAV414 Together with temperature, pressure is one of the most significant physical quantities in process measurement technology. Correspondingly, the range of sensor principles currently in use is large. In


    Original
    PDF CAN404 CAV414 CAV414 water level sensor schematic diagram capacitive sensor for water level measurement schematic inductive sensor capacitive level sensor circuit drawing capacitive level sensor circuit diagram water level sensor circuit schematic level water namur standard AM-422

    CAV414

    Abstract: 200K trimmer
    Text: APPLICATION NOTE CAV414 Functional Description The functional description gives the necessary formulas to calculate the CAV414 with the sensing element capacitor of a capacitive sensor . The formulas are a good approximation of the reality. Reference Oscillator:


    Original
    PDF CAV414 CAV414 100ppm/ 50ppm/ 100nF 200K trimmer

    high current converter circuit diagram

    Abstract: CAV414 DIL16 instrumentation amplifier for capacitive sensors dt720
    Text: Converter IC for Capacitive Signals CAV414 FEATURES GENERAL DESCRIPTION • Wide Supply Voltage Range: 6.35V • Wide Operating Temperature Range: –40°C.+85°C • High Detection Sensitivity of Relative Capacitive Changes: 5% – 100% • Detection Frequency up to 2kHz


    Original
    PDF CAV414 5/10V, CAV414 high current converter circuit diagram DIL16 instrumentation amplifier for capacitive sensors dt720

    CAV444

    Abstract: water level sensor schematic diagram analog to digital converter ic linear measurement rs232 schematic diagram CAV414 capacitive sensor water level detection circuit diagram water level sensor water level capacitance circuit schematic electrode level water
    Text: CAV444 – Capacitance/Voltage Transmitter IC with Linear Transfer Function Analog Microelectronics is pleased to present beside the CAV414 and CAV424 the new IC CAV444 [1]. The capacitance-to-voltage transmitter IC with a linear, differential output voltage can


    Original
    PDF CAV444 CAV414 CAV424 CAV414, CAV444. CAV444: CAV414: CAV444 water level sensor schematic diagram analog to digital converter ic linear measurement rs232 schematic diagram capacitive sensor water level detection circuit diagram water level sensor water level capacitance circuit schematic electrode level water

    cav414

    Abstract: attiny adc AM402 PR1007 tiny11 AM422 PR1003 PR1004
    Text: Digital correction of capacitive signals with the aid of Frame ASIC CAV414 Measurements and readings are never completely accurate and must always be corrected using suitable methods in order to keep within the required error margins. One modern approach is to calibrate and compensate the measured sensor signal with the aid of correction


    Original
    PDF CAV414 CAV414. PR1007 CAV414: PR1003 CAV414 AM402 attiny adc PR1007 tiny11 AM422 PR1003 PR1004

    trimmer capacitor analog 100pf

    Abstract: 10pf ceramic CAPACITOR CAV414 equivalent diode for R2C
    Text: APPLICATION NOTE CAV414 Functional Description The functional description gives the necessary formulas to calculate the CAV414 with the sensing element capacitor of a capacitive sensor . The formulas are a good approximation of the reality. Reference Oscillator:


    Original
    PDF CAV414 CAV414 00ppm/ 100ppm/ 50ppm/ 100nF trimmer capacitor analog 100pf 10pf ceramic CAPACITOR equivalent diode for R2C

    AM402

    Abstract: CAV414 attiny 85 pwm AM422 CAN404 adjustable zero span amplifier ic
    Text: Digital correction of capacitive signals with the aid of Frame ASIC CAV414 Measurements and readings are never completely accurate and must always be corrected using suitable methods in order to keep within the required error margins. One modern approach is to calibrate and compensate the measured sensor signal with the aid of correction algorithms implemented by a processor. There are integrated solutions currently


    Original
    PDF CAV414 CAV414. de/products/info/german/pr1007 CAV414: de/products/sheets/english/cav414 de/products/sheets/german/appli414 CAV414 AM402 de/products/sheets/english/appli414 attiny 85 pwm AM422 CAN404 adjustable zero span amplifier ic

    AM402

    Abstract: ANALOGE kor 2001 AM400 CAN404 CAV414
    Text: Signalauswerteschaltungen für Sensoren "Frame–ASICs*" oder die Modulare Signalauswertung Sensorsignale sind von Natur aus fehlerbehaftet und müssen mit geeigneten Methoden so korrigiert werden, daß bestimmte Fehlergrenzen eingehalten werden. Eine Methode ist, mit Hilfe von digitalen Komponenten das Sensorsignal zu kalibrieren und zu kompensieren. Auf dem Markt existieren eine Reihe von integrierten Lösungen, die eine solche elektronische Korrektur erlauben. Meist sind


    Original
    PDF AM400: de/products/sheets/german/am400 AM400 AM402 ANALOGE kor 2001 AM400 CAN404 CAV414

    instrumentation amplifier for capacitive sensors

    Abstract: precision 4-20ma current source Voltage to Current Converter circuit 4-20mA Current to Voltage Converter 4-20mA Voltage to Current Converter 4-20mA ANALOG MICROELECTRONICS Voltage-to-Current Converter 4-20mA voltage to current converter 4 to 20ma circuit current to voltage converter namur driver
    Text: analog microelectronics PRODUCT GUIDE Standard ICs Sensor Transmitter ICs Amplifier and Protection ICs Voltage-to-Current Converter ICs Voltage-to-Voltage Converter ICs Converter ICs for Capacitive Signals Converter ICs for Single Ended Signals Special Protection Function ICs


    Original
    PDF

    stromquelle

    Abstract: 4 bis 20 mA stromquelle AM417 AM432 dil16 0-10V 4.....20MA AM402 CAV424 AM400 SO16
    Text: analog microelectronics PRODUKTFÜHRER Standard-ICs Sensor-Transmitter-ICs Verstärker- und Schutz-ICs Spannungs-/Strom-Wandler-ICs Spannungs-/Spannungs-Wandler-ICs Wandler-ICs für kapazitive Signale Wandler-ICs für massebezogene Signale Spezielle Schutz- und Treiber-ICs


    Original
    PDF AM400 AM40Oktober 201108s stromquelle 4 bis 20 mA stromquelle AM417 AM432 dil16 0-10V 4.....20MA AM402 CAV424 AM400 SO16

    small capacitive oil level sensor

    Abstract: water level sensor schematic diagram moisture measurement capacitive sensor AM402 10-farad CAV424 PR1008 R01 filters AM337 AM401
    Text: Conversion of capacitive signals with the aid of IC CAV424 In order to condition signals from capacitive sensing elements used to measure moisture, acceleration, levels and angles, to date systems designers have had to rely primarily on discrete circuits or have customer-specific ICs CSICs developed. The many areas and applications


    Original
    PDF CAV424 CAV424, CAV424 CAV424: PR1007 PR1008 small capacitive oil level sensor water level sensor schematic diagram moisture measurement capacitive sensor AM402 10-farad PR1008 R01 filters AM337 AM401

    cav414

    Abstract: Surround processor schematic AM402 CAN404 "Signal Conditioning" AM400 namur output analog sensor
    Text: Signal Conditioning Circuits for Sensors Frame ASICs* or Modular Signal Conditioning Sensor signals are, by their nature, not perfect and must be corrected with suitable techniques in such a way that target error levels are achieved. One method is to calibrate and compensate the sensor signal with digital components. On the market,


    Original
    PDF AM400 cav414 Surround processor schematic AM402 CAN404 "Signal Conditioning" namur output analog sensor

    PR1008

    Abstract: AM402 digitale schaltungen AM400 AM401 AM411 AM417 AM427 CAN404 CAV414
    Text: Wandlung kapazitiver Signale mit Hilfe des ICs CAV424 Für die Signalauswertung von kapazitiven Meßzellen im Bereich der Feuchtemessung, der Füllstandsanzeige, der Beschleunigungs- und Winkelmessung mußten Entwickler bisher weitgehend auf diskrete Schaltungen zurückgreifen oder kundenspezifische ICs


    Original
    PDF CAV424 CAV424, CAV424 PR1007 PR1008 PR1008 AM402 digitale schaltungen AM400 AM401 AM411 AM417 AM427 CAN404 CAV414