Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CAESIUM-ANTIMONY SPECTRAL RESPONSE Search Results

    CAESIUM-ANTIMONY SPECTRAL RESPONSE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    LM161H/883 Rochester Electronics LLC Comparator, 3000uV Offset-Max, 14ns Response Time, BIPolar, MBCY10, Visit Rochester Electronics LLC Buy
    LM106H Rochester Electronics LLC Comparator, 1 Func, 2000uV Offset-Max, 28ns Response Time, BIPolar, MBCY8, METAL CAN-8 Visit Rochester Electronics LLC Buy
    LM710CH Rochester Electronics LLC Comparator, 1 Func, 5000uV Offset-Max, 40ns Response Time, BIPolar, MBCY8, METAL CAN-8 Visit Rochester Electronics LLC Buy
    LM760J/883 Rochester Electronics LLC Comparator, 1 Func, 6000uV Offset-Max, 16ns Response Time, BIPolar, CDIP8, CERAMIC, DIP-8 Visit Rochester Electronics LLC Buy
    LM361J Rochester Electronics LLC LM361 - Comparator, 1 Func, 5000uV Offset-Max, 12ns Response Time, BIPolar, CERAMIC, DIP-14 Visit Rochester Electronics LLC Buy

    CAESIUM-ANTIMONY SPECTRAL RESPONSE Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: Hollow Cathode Lamps Overview Atomic absorption spectroscopy or AAS in its modern form came from principles developed by Australian physicist Dr. A. Walsh in 1955. Atomic absorption spectroscopy is ideal for analyzing minute quantities of metallic elements because its operating principle and analysis method


    Original
    PDF SE-164 1014E01

    photomultiplier

    Abstract: photomultiplier 8 stage JT INDUSTRIES Scans-0017376
    Text: 27M13 EDISWAN 27MI3 SEVEN STAGE PHOTO-MULTIPLIER G EN ERA L The 27M13 is a seven stage Photo-multiplier having a blue sensitive cathode and twin anodes. Its sensitivity in typical operation is 2.5 amps/lumen. The cathode surface is of •<Caesium Antimony.


    OCR Scan
    PDF 27M13 27MI3 27M13 photomultiplier photomultiplier 8 stage JT INDUSTRIES Scans-0017376

    phototube philips spectral response

    Abstract: 90AV k938 radiation tube phototube 939 phototube
    Text: PHILIPS 90 AV High vacuum PH0T0CELL CELLULE PHOTOELECTRIQUE à vide poussé Hochvakuum PHOTOZELLE Cathode: Cathode; Kathode: Caesium Césium Cäsium - antimony, blue sensitive - antimoine, sensible au bleu - Antimon, blau empfindlich Dimensions in mra Dimensions


    OCR Scan
    PDF 90AVI phototube philips spectral response 90AV k938 radiation tube phototube 939 phototube