Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    BS EN 60898 MCB Search Results

    BS EN 60898 MCB Result Highlights (1)

    Part ECAD Model Manufacturer Description Download Buy
    RTK0EMA270C00000BJ Renesas Electronics Corporation MCB-RA6T2 CPU Board for RA6T2 MCU Group Visit Renesas Electronics Corporation

    BS EN 60898 MCB Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Circuit Breakers to BS EN 60898

    Abstract: 2 pole mcb C60HD vigi C60 1 pole C60H RCBO C60HC mcb C60HB 3 pole vigi vigi C60H 3p 63a
    Text: C60H Miniature circuit breakers Ratings 1 to 63A C60HB type B 3 - 5In Applications Protection and control of circuits against overloads and short circuits. • In applications with general load characteristics. ■ Tripping characteristics: BS EN 60898 type B:


    Original
    PDF C60HB C60HC 110/240V, 50/60Hz, 240/415V, 50/60Hz. 25mm2, 35mm2. Circuit Breakers to BS EN 60898 2 pole mcb C60HD vigi C60 1 pole C60H RCBO mcb C60HB 3 pole vigi vigi C60H 3p 63a

    ABB RD2 earth leakage relay

    Abstract: DS651 RD2 earth leakage relay E251-230 E76126 S272C10 S272C6 ABB DC Main Circuit breaker 2POLE ABB MCCB SHUNT TRIP S273-K32
    Text: Line Protection Contents Miniature Circuit Breakers MCB’s . 3-2 Protecta Type B Pan Assemblies . 3-12 High Performance MCB’s.


    Original
    PDF ESB20 ESB24 ESB40 ESB63 ABB RD2 earth leakage relay DS651 RD2 earth leakage relay E251-230 E76126 S272C10 S272C6 ABB DC Main Circuit breaker 2POLE ABB MCCB SHUNT TRIP S273-K32

    Merlin Gerin c60hd

    Abstract: Circuit Breakers to BS EN 60898 Merlin Gerin c60hb Merlin Gerin CIRCUIT BREAKER merlin gerin C60H merlin gerin C60H characteristics c60hc C60H dc 4P 63A MERLIN C60H 3p 63a
    Text: C60H Isobar 4 outgoers miniature circuit breakers 1 - 63A Installation • ■ ■ ■ In Merlin Gerin Isobar 4 distribution boards Symmetrical DIN rail Direct panel mounting Isobar 4 pan assemblies Technical data ■ 1, 2, 3 and 4 pole Type B Miniature circuit breakers


    Original
    PDF 440Vac -300C Dime24880 C60HD C60HD Merlin Gerin c60hd Circuit Breakers to BS EN 60898 Merlin Gerin c60hb Merlin Gerin CIRCUIT BREAKER merlin gerin C60H merlin gerin C60H characteristics c60hc C60H dc 4P 63A MERLIN C60H 3p 63a

    c60hc

    Abstract: EN60898 C60HD type d 20 circuit-breaker C60H MINIATURE CIRCUIT BREAKER Breaking capacity C60H dc Circuit Breakers to BS EN 60898 C60H c60h 2p C60HD
    Text: C60H Miniature circuit breakers Ratings 1 to 63A, breaking capacity 15kA Installation • ■ ■ Symmetrical DIN rail. Direct panel mounting. Isobar 4 pan assemblies. Technical data ■ ■ ■ 1, 2, 3 and 4 pole Type B Miniature circuit breakers Current ratings: 1 to 63A at 300C to BS EN60898.


    Original
    PDF EN60898. -300C BS7671. C60HC c60hc EN60898 C60HD type d 20 circuit-breaker C60H MINIATURE CIRCUIT BREAKER Breaking capacity C60H dc Circuit Breakers to BS EN 60898 C60H c60h 2p C60HD

    mcb tripping curves

    Abstract: MCB ENERGY LET THROUGH MCB ENERGY LET THROUGH 60898 type b motor current mcb tripping type c mcb tripping curves Circuit Breakers to BS EN 60898 type 2 mcb 16A hrc fuse discrimination mcb type c 6A type b mcb
    Text: TECHNICAL DATA SHEET Sentry Miniature Circuit Breakers 1:3 Sentry MCBs Description PRODUCT RANGE Sentry MCBs are of the thermo-magnetic, current limiting type and are available with either Type B or Type C operating characteristics. Type B Single pole Rating


    Original
    PDF 5903s 5906s 5910s 5916s 5920s 5932s 5940s mcb tripping curves MCB ENERGY LET THROUGH MCB ENERGY LET THROUGH 60898 type b motor current mcb tripping type c mcb tripping curves Circuit Breakers to BS EN 60898 type 2 mcb 16A hrc fuse discrimination mcb type c 6A type b mcb

    wiring diagram of rccb

    Abstract: rcbo circuit diagram mcb circuit diagram ASN100 A16UE type b mcb mcb tripping curves mem RCBO Circuit Breakers to BS EN 60898 AA633
    Text: PROTECTIVE DEVICES & ACCESSORIES MEMERA A comprehensive range of protective devices and accessories to complement both the Memera 2000 and Memera 2000 AD consumer unit range. 250 Ancillary devices Contactors and impulse relays 253-254 253 Enclosures 255 HRC fuse modules


    Original
    PDF ALB061 25mm2; wiring diagram of rccb rcbo circuit diagram mcb circuit diagram ASN100 A16UE type b mcb mcb tripping curves mem RCBO Circuit Breakers to BS EN 60898 AA633

    DPN vigi

    Abstract: DPN RCBO mcb rating 10 19663 mcb wiring mcb c CURVE TRIPPING VOLTAGE 20 A 400C BS7671 IEC664 rcbo type ac
    Text: DPN RCBO Combined MCB/RCD Application Protection against the effects of earth leakage, overload and short circuit currents. • 2 pole switching of phase & neutral. Phase protected against overloads and short circuits. ■ Commercial, industrial and domestic electrical


    Original
    PDF BS7671) 110/240V. 16mm2 25mm2 00A/240V IEC664 DPN vigi DPN RCBO mcb rating 10 19663 mcb wiring mcb c CURVE TRIPPING VOLTAGE 20 A 400C BS7671 IEC664 rcbo type ac

    DPN vigi

    Abstract: IEC-664 mcb tripping curves BS7671 DPN RCBO IEC664 14880 6100 RCBO vigi dpn
    Text: DPN RCBO Combined MCB/RCD 1P + switched neutral Application Protection against the effects of earth leakage, overload and short circuit currents. • 2 pole switching of phase & neutral. Phase protected against overloads and short circuits ■ Commercial, industrial and domestic electrical


    Original
    PDF BS7671) 110/240V 25mm2 16mm2 00A/240V IEC664 DPN vigi IEC-664 mcb tripping curves BS7671 DPN RCBO IEC664 14880 6100 RCBO vigi dpn

    mcb tripping curves

    Abstract: NG125N c60 tripping curves NC100H NS400H NG125H Multi 9 C60HD c60hc c1 380V 415v motor c60h tripping curves
    Text: Miniature circuit breakers Breaking capacities Tripping characteristics Miniature circuit breaker magnetic trip setting Type C60HB MCB (type B: 3-5In) C60HC MCB (type C: 5-10In C60HD MCB (type D: 10-14In) C120 HB MCB C120 HC MCB C120 HD MCB NG125 N NG125 H


    Original
    PDF C60HB C60HC 5-10In C60HD 10-14In) NG125 C60HB C60HC C60HD mcb tripping curves NG125N c60 tripping curves NC100H NS400H NG125H Multi 9 C60HD c60hc c1 380V 415v motor c60h tripping curves

    mccb 60947-2 max zs

    Abstract: 60947-2 MAX EARTH LOOP IMPEDANCE wiring diagram of rccb hager mcb 3 phase MCB installation drawing hager HD149U rcbo circuit diagram HMF280T ADA925U
    Text: Auxiliaries and accessories 3.5 RCCB add-on blocks 3.6 Miniature cicruit breakers 80-125A 3.8 Single pole & switch neutral devices 3.15 2 & 4 pole RCCBs 3.16 RCCB auxiliaries 3.17 RCBO single pole 3.18 RCBO single pole and switched neutral 3.19 HRC fuse carriers and


    Original
    PDF 0-125A 630ples mccb 60947-2 max zs 60947-2 MAX EARTH LOOP IMPEDANCE wiring diagram of rccb hager mcb 3 phase MCB installation drawing hager HD149U rcbo circuit diagram HMF280T ADA925U

    MCB ENERGY LET THROUGH

    Abstract: Circuit Breakers to BS EN 60898 MCB ENERGY LET THROUGH 60898 type b mcb type c 6A type b mcb mcb wiring HRC BT bs 1361 LS CIRCUIT BREAKERS ABS1361
    Text: S e n t r y Technical 661 | circu it p ro tectio n technical ho tline + 4 4 0 1 26 8 5 6 3 7 20 M in ia tu re C irc u it B re a k e rs (M C B s ) S t a n d a rd s a n d a p p ro v a ls Sentry MCBs are designed to fu lly c om p ly w ith th e relev ant req u irem ents of BS E N 6 0 8 9 8 : 20 0 3 .


    Original
    PDF

    PFIM

    Abstract: PLS-6 PLS6-B12 PLS6-B25 BSEN60898 sg1900 630848 SG19002 1NB01 SG180
    Text: Consumer Units tra Combinations Consumer Units Designed and built to the latest British and European standards to meet the needs of the building and refurbishment markets. A variety of MCB’s, RCD’s and RCBO’s offer outstanding performance with 6kA and 10kA


    Original
    PDF PKS6-6/1N/D/001 PKS6-8/1N/D/001 PKS6-10/1N/D/001 PKS6-13/1N/D/001 PKS6-16/1N/D/001 PKS6-20/1N/D/001 PFIM PLS-6 PLS6-B12 PLS6-B25 BSEN60898 sg1900 630848 SG19002 1NB01 SG180

    mccb 60947-2 max zs

    Abstract: 60947-2 MAX EARTH LOOP IMPEDANCE hager 3 phase MCB installation drawing hager mcb HD149U MCCB wiring diagram HD148U IEC 60947-2 max zs HN204
    Text: Auxiliaries and accessories 3.5 RCCB add-on blocks 3.6 Miniature cicruit breakers 80-125A 3.8 Single pole & switch neutral devices 3.15 2 & 4 pole RCCBs 3.16 RCCB auxiliaries 3.17 RCBO single pole 3.18 RCBO single pole and switched neutral 3.19 HRC fuse carriers and


    Original
    PDF 0-125A 630ples mccb 60947-2 max zs 60947-2 MAX EARTH LOOP IMPEDANCE hager 3 phase MCB installation drawing hager mcb HD149U MCCB wiring diagram HD148U IEC 60947-2 max zs HN204

    merlin gerin multi 9 ihp 1c manual

    Abstract: NS800N telemecanique contactor catalogue schneider NS1250N merlin gerin multi 9 ihp 1c Merlin Gerin NS1250N merlin gerin multi 9 ihp 1c program timer NS1250n 29450 SCHNEIDER schneider pm710
    Text: Ready to install Distribution boards, DIN rail mounted equipment, enclosures and connection systems Contents Isobar 4 distribution boards and protective devices Section one 7 Modular control products Section two 31 Unit mounted residual current devices Section three


    Original
    PDF 16kA11000 MGLV5750 merlin gerin multi 9 ihp 1c manual NS800N telemecanique contactor catalogue schneider NS1250N merlin gerin multi 9 ihp 1c Merlin Gerin NS1250N merlin gerin multi 9 ihp 1c program timer NS1250n 29450 SCHNEIDER schneider pm710

    Merlin Gerin NS630N

    Abstract: merlin gerin NS250N merlin gerin ns160n C801N NS250N Merlin Gerin mccb C801N MERLIN GERIN STR22SE merlin gerin multi 9 CT NS400N
    Text: Technical data Section 9 Miniature circuit breakers Breaking capacities Tripping characteristics B type distribution board de-rating table Board Standard MGB4N Split load Multi service Heavy duty Busbar rating 250A 200A 160A 250A 100A Integral MCCB 0.9 0.9


    Original
    PDF MCCB2503D4P) MGB12N) Merlin Gerin NS630N merlin gerin NS250N merlin gerin ns160n C801N NS250N Merlin Gerin mccb C801N MERLIN GERIN STR22SE merlin gerin multi 9 CT NS400N

    mccb 60947-2 max zs

    Abstract: MCB ENERGY LET THROUGH HRC fuse gg GEC mcb tripping curves mcb technical detail b112c NSB310-C 80A mccb curve 400a mccb Wylex 604
    Text: Circuit Protection 2003 Founded in 1897, Wylex introduced the first ‘consumer unit’ to the electrical industry, this original design was the forerunner to the ‘Standard Range’, which is still in wide use today. From its base at Wythenshawe, through


    Original
    PDF

    PFIM

    Abstract: PLS-6 PLS6-C10 Moeller PFIM 1KWO Moeller Xboard PLS6-C32 BC-P10SR80 Z-SCH230 circuit breakers mcb Pfim
    Text: www.moeller.co.uk XBoard Consumer Units stylish and easy to fit Product Catalogue and Selection Guide XBoard – Insulated and Metal Consumer Units XPole – Miniature Circuit Breakers, RCDs and RCBOs XBoard Consumer Units XPole Miniature Circuit Breakers, RCDs and


    Original
    PDF 100mA PLS6-C16 PKS6-6/1N/C/003 PKS6-6/1N/C/01 PLS6-C20 PKS6-10/1N/C/003 PKS6-10/1N/C/01 PLS6-C25 PKS6-13/1N/C/003 PKS6-13/1N/C/01 PFIM PLS-6 PLS6-C10 Moeller PFIM 1KWO Moeller Xboard PLS6-C32 BC-P10SR80 Z-SCH230 circuit breakers mcb Pfim

    WYLEX

    Abstract: carlo gavazzi SP 115 230
    Text: domestic commercial industrial circuit protection Founded in 1897, Wylex introduced the first ‘consumer unit’ to the electrical industry, this original design was the forerunner to the ‘Standard Range’, which is still in wide use today across the world.


    Original
    PDF WY2074a WYLEX carlo gavazzi SP 115 230

    T5N630 ABB

    Abstract: bs 1600 pir sensor T5N630 1SDA054396R1 1SDA05 magnetic Contactor abb a9-30-10 ABB 145 PM 40-20 Breaker T5N400 ABB 1SDA054404R1 S202MC6
    Text: Low Voltage Equipment Innovative Products for the Electrical Contractor - April 2006 Contractor Products Welcome The 5th Edition 1 Welcome to the fifth edition Epack Catalogue which continues to combine a range of products from ABB specially selected for the electrical contractor.


    Original
    PDF 1TXD000001P0205 T5N630 ABB bs 1600 pir sensor T5N630 1SDA054396R1 1SDA05 magnetic Contactor abb a9-30-10 ABB 145 PM 40-20 Breaker T5N400 ABB 1SDA054404R1 S202MC6

    design of earth busbar for 50kA fault level system

    Abstract: BUSBAR calculation free 400a mccb Switchboard BUSBAR calculation of lv switchboard earth BUSBAR calculation traffolyte ral 7035 paint EN60439-1 raychem arresters
    Text: Energy Division http://energy.tycoelectronics.com Loadframe 25/63 LV Switchboard System Loadframe 25/63 LV Switchboard System The Loadframe family of factory-assembled switchboards comprehensively covers all LV switchboard requirements up to 6300A 4.5MVA . This range of Type Tested


    Original
    PDF

    60947-2 MAX EARTH LOOP IMPEDANCE

    Abstract: S2C-H10 ABB STOTZ - S 212 M 59371 s201h S2C-A1 stotz s 212 transistor r1009 IEC 60947-2 ABB S200M
    Text: Technical Data System pro M System pro M compact Miniature Circuit-Breakers for Railway Applications Railway application prEN 45545-1 Level HL4 220/440 V DC 230/400 V AC 60 V DC 230/400 V AC 1. Fire Resistance Miniature circuit-breakers of the S 200 P and S 280 UC series,


    Original
    PDF F16-101/-102, 50155/EN D0201 60947-2 MAX EARTH LOOP IMPEDANCE S2C-H10 ABB STOTZ - S 212 M 59371 s201h S2C-A1 stotz s 212 transistor r1009 IEC 60947-2 ABB S200M

    PR221DS sace tmax

    Abstract: ABB RD2 earth leakage relay 2CSC400002D0205 mccb 60947-2 max zs ABB Sace Tmax S941N C2 60947-2 MAX EARTH LOOP IMPEDANCE BSEN 60898 R0427 50Hz to 60Hz 400v circuit diagram SQZ3
    Text: Technical catalogue System pro M compact and other modular devices for low voltage installation System pro M compact® and other modular devices for low voltage installation In consideration of modifications to Standards and materials, the characteristics


    Original
    PDF 2CSC400002D0205 pr11-2006 PR221DS sace tmax ABB RD2 earth leakage relay mccb 60947-2 max zs ABB Sace Tmax S941N C2 60947-2 MAX EARTH LOOP IMPEDANCE BSEN 60898 R0427 50Hz to 60Hz 400v circuit diagram SQZ3

    2CSC400002D0903

    Abstract: 2CSG210200R1211 ABB E 257 C30-230 S465502 2CSG035100R1211 2CSG210100R1211 ABB SACE sn 125 EA1733 LCD TV SCHEMA S550284
    Text: Catalogo tecnico System pro M compact System pro M Interruttori magnetotermici, differenziali e apparecchi modulari per impianti in bassa tensione System pro M compact® - System pro M Per tener conto dell’evoluzione delle Norme e dei materiali, le caratteristiche e le dimensioni di ingombro indicate nel presente


    Original
    PDF 2CSC400002D0903 2CSG210200R1211 ABB E 257 C30-230 S465502 2CSG035100R1211 2CSG210100R1211 ABB SACE sn 125 EA1733 LCD TV SCHEMA S550284

    ABB DC Main Circuit breaker 2POLE

    Abstract: S2C-A2 ABB STOTZ - S 212 S2C-H6R 60947-2 MAX EARTH LOOP IMPEDANCE S2CA2 stotz s 212 S2C-A1 60947-2 max zs mcb tripping curves
    Text: System pro M compact ȭ Technical data System Navigate pro MDocument compact Miniature circuit-breakers S 200/S 200 M Residual-current-operated circuit-breakers F 200 Cross wiring/accessories 1 System pro M compact ® Miniature circuit-breaker S 201 Standard Terms for Delivery and Sale


    Original
    PDF 200/S D0203 ABB DC Main Circuit breaker 2POLE S2C-A2 ABB STOTZ - S 212 S2C-H6R 60947-2 MAX EARTH LOOP IMPEDANCE S2CA2 stotz s 212 S2C-A1 60947-2 max zs mcb tripping curves