Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    AUTOTRANSFORMER APPLICATION Search Results

    AUTOTRANSFORMER APPLICATION Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    C8231A Rochester Electronics LLC Math Coprocessor, 8-Bit, NMOS, CDIP24, DIP-24 Visit Rochester Electronics LLC Buy
    AM79865JC Rochester Electronics LLC Telecom Circuit, Visit Rochester Electronics LLC Buy
    AM79866AJC-G Rochester Electronics LLC SPECIALTY TELECOM CIRCUIT, PQCC20, ROHS COMPLIANT, PLASTIC, LCC-20 Visit Rochester Electronics LLC Buy
    MD8087/R Rochester Electronics LLC Math Coprocessor, CMOS Visit Rochester Electronics LLC Buy
    AM7992BPC Rochester Electronics LLC Manchester Encoder/Decoder, PDIP24, PLASTIC, DIP-24 Visit Rochester Electronics LLC Buy

    AUTOTRANSFORMER APPLICATION Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    24V to 12V REGULATOR IC

    Abstract: autotransformer 12V to 24V REGULATOR IC autotransformer design autotransformer application voltage regulator mosfet fly-back 12V mosfet voltage regulator flyback transformer 12v dc AN1016
    Text: Maxim > App Notes > POWER-SUPPLY CIRCUITS Keywords: inverting, dc-dc regulator, autotransformer, switching regulator, ICs, integrated circuit Jul 09, 1998 APPLICATION NOTE 1016 Autotransformer Regulator Inverts 12V to -12V Abstract: The autotransformer provides an alternative means of extending the output voltage range of an


    Original
    200mA com/an1016 MAX764: AN1016, APP1016, Appnote1016, 24V to 12V REGULATOR IC autotransformer 12V to 24V REGULATOR IC autotransformer design autotransformer application voltage regulator mosfet fly-back 12V mosfet voltage regulator flyback transformer 12v dc AN1016 PDF

    autotransformer

    Abstract: AN496 TRANSFORMER 9V APP496 MAX857 Step-up 36V
    Text: Maxim > App Notes > POWER-SUPPLY CIRCUITS Keywords: Autotransformer Boosts Maximum VOUT Jul 09, 1998 APPLICATION NOTE 496 Autotransformer Boosts Maximum VOUT Step-up dc-dc converters that operate from small input voltages often have correspondingly low maximum


    Original
    com/an496 MAX857: AN496, APP496, Appnote496, autotransformer AN496 TRANSFORMER 9V APP496 MAX857 Step-up 36V PDF

    Untitled

    Abstract: No abstract text available
    Text: "Auto" Step Up - Plug In 176 Series Line Autotransformer Step Up - Plug In (115V to 230V) • Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required. • World wide applications, 50 or 60 Hz. operation, step up (115VAC to 230VAC).


    Original
    115VAC 230VAC) 5-15P) 6-15R) E211544) PDF

    STEP UP

    Abstract: No abstract text available
    Text: "Auto" Step Up - Plug In 176 Series Line Autotransformer Step Up - Plug In (115V to 230V) • Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required. • World wide applications, 50 or 60 Hz. operation, step up (115VAC to 230VAC).


    Original
    115VAC 230VAC) 5-15P) 6-15R) E211544) STEP UP PDF

    max14521

    Abstract: No abstract text available
    Text: Document 717 Shielded Coupled Inductor For Maxim MAX14521E • Developed for Maxim MAX14521E High-Voltage EL Lamp Driver with I²C Interface • Used as a 1 : 8 autotransformer • Shielded part for high-density applications Core material Ferrite Terminations RoHS compliant silver-palladium-platinum-glass frit.


    Original
    MAX14521E MAX14521E max14521 PDF

    GA3250

    Abstract: GA3250-BL max14521
    Text: Document 717 Shielded Coupled Inductor For Maxim MAX14521E • Developed for Maxim MAX14521E High-Voltage EL Lamp Driver with I²C Interface • Used as a 1 : 8 autotransformer • Shielded part for high-density applications Core material Ferrite Environmental RoHS compliant, halogen free optional


    Original
    MAX14521E MAX14521E GA3250 GA3250-BL max14521 PDF

    Untitled

    Abstract: No abstract text available
    Text: Surface Mount RF Transformer 50Ω TC4-11G2+ 2 to 1100 MHz Features Maximum Ratings Operating Temperature Storage Temperature -20°C to 85°C -55°C to 100°C RF Power 0.25W DC Current 30mA • wideband, 2 to 1100 MHz • good return loss • step-down autotransformer


    Original
    TC4-11G2+ AT224-3 M107839 PDF

    Untitled

    Abstract: No abstract text available
    Text: Surface Mount RF Transformer 50Ω TC4-11G2+ 2 to 1100 MHz Features Maximum Ratings Operating Temperature Storage Temperature -20°C to 85°C -55°C to 100°C RF Power 0.25W DC Current 30mA • wideband, 2 to 1100 MHz • good return loss • step-down autotransformer


    Original
    TC4-11G2+ AT224-3 2002/95/EC) M107839 PDF

    Untitled

    Abstract: No abstract text available
    Text: Surface Mount RF Transformer 50Ω TC4-11G2+ 2 to 1100 MHz Features Maximum Ratings Operating Temperature Storage Temperature -20°C to 85°C -55°C to 100°C RF Power 250mW DC Current 30mA • wideband, 2 to 1100 MHz • good return loss • step-down autotransformer


    Original
    TC4-11G2+ 250mW AT224-3 2002/95/EC) TC4-11 M107839 PDF

    Untitled

    Abstract: No abstract text available
    Text: Surface Mount RF Transformer 50Ω TC4-11G2+ 2 to 1100 MHz Features Maximum Ratings Operating Temperature Storage Temperature -20°C to 85°C -55°C to 100°C RF Power 250mW DC Current 30mA • wideband, 2 to 1100 MHz • good return loss • step-down autotransformer


    Original
    250mW TC4-11G2+ AT224-3 2002/95/EC) TB-276 M107839 PDF

    Untitled

    Abstract: No abstract text available
    Text: Surface Mount RF Transformer 50Ω TC4-11G2+ 2 to 1100 MHz Features Maximum Ratings Operating Temperature Storage Temperature -20°C to 85°C -55°C to 100°C RF Power 0.25W DC Current 30mA • wideband, 2 to 1100 MHz • good return loss • step-down autotransformer


    Original
    TC4-11G2+ AT224-3 2002/95/EC) TC4-11 M107839 PDF

    Untitled

    Abstract: No abstract text available
    Text: Surface Mount RF Transformer 50Ω TC4-11G2+ 2 to 1100 MHz Features Maximum Ratings Operating Temperature Storage Temperature -20°C to 85°C -55°C to 100°C RF Power 0.25W DC Current 30mA • wideband, 2 to 1100 MHz • good return loss • step-down autotransformer


    Original
    TC4-11G2+ AT224-3 M107839 PDF

    AT224-3

    Abstract: TC4-11 TC4-11G2
    Text: Surface Mount RF Transformer 50Ω TC4-11G2+ 2 to 1100 MHz Features Maximum Ratings Operating Temperature Storage Temperature -20°C to 85°C -55°C to 100°C RF Power 0.25W DC Current 30mA • wideband, 2 to 1100 MHz • good return loss • step-down autotransformer


    Original
    TC4-11G2+ AT224-3 2002/95/EC) TC4-11 M107839 AT224-3 TC4-11 TC4-11G2 PDF

    Untitled

    Abstract: No abstract text available
    Text: E-Series RF 1.5:1 Transformer — 5 - 1000 MHz ETC1.5-4 ETC1.5-4 E-Series RF 1.5:1 Step-down AutoTransformer Features • • • SM-22 Package Surface Mount 1.5:1 Impedance Ratio Available on Tape & Reel 0.030 0.762 0.050 (1.27) 0.150 (3.81) 0.030 (0.762)


    Original
    SM-22 PDF

    AT224-3

    Abstract: TC4-11
    Text: Surface Mount RF Transformer 50Ω TC4-11G2+ 2 to 1100 MHz Features Maximum Ratings Operating Temperature Storage Temperature -20°C to 85°C -55°C to 100°C RF Power 0.25W DC Current 30mA • wideband, 2 to 1100 MHz • good return loss • step-down autotransformer


    Original
    TC4-11G2+ AT224-3 2002/95/EC) M107839 AT224-3 TC4-11 PDF

    51700

    Abstract: No abstract text available
    Text: Surface Mount ADT1.5-17+ ADT1.5-17 RF Transformer 50Ω Ω .5 to 1700 MHz Maximum Ratings Features Operating Temperature Storage Temperature RF Power DC Current -20°C to 85°C -55°C to 100°C 0.25W 30mA • • • • • wideband, 0.5 to 1700 MHz autotransformer


    Original
    CD542 2002/95/EC) TB-40 M98898 51700 PDF

    Untitled

    Abstract: No abstract text available
    Text: Surface Mount RF Transformer 50Ω TC4-11G2+ 2 to 1100 MHz Features Maximum Ratings Operating Temperature Storage Temperature -20°C to 85°C -55°C to 100°C RF Power 250mW DC Current 30mA • wideband, 2 to 1100 MHz • good return loss • step-down autotransformer


    Original
    TC4-11G2+ 250mW AT224-3 2002/95/EC) TB-276 TC4-11 M107839 PDF

    autotransformer design

    Abstract: 3 winding phase shifting transformer autotransformer equivalent circuit autotransformer multiple winding Transformer pulse transformer circuit 4 way power divider stepdown transformer TRANSFORMER for pc Signal Path Designer
    Text: Document 157-1 Signal Transformer Application and Specification A transformer in its simplest sense is two or more windings coupled by a common magnetic field flux density . It is this magnetic field that provides the means to pass voltages and currents from one winding (primary) to


    Original
    PDF

    equivalent circuit autotransformer

    Abstract: autotransformer design autotransformer autotransformer application step down transformer winding ratio transformer with primary to secondary turns ratio types of autotransformer AUTO TRANSFORMERS Wideband Power Transformers 3 winding phase shifting transformer
    Text: Document 157-1 Signal Transformer Application and Specification In the simplest sense, a transformer is two or more windings coupled by a common magnetic field. This magnetic field provides the means to pass voltages and currents from one winding primary to the other winding (secondary).


    Original
    PDF

    diac advantageS AND DISADVANTAGES

    Abstract: No abstract text available
    Text: AN10961 Dimmable CFL using the UBA2027X family Rev. 2 — 8 June 2012 Application note Document information Info Content Keywords CFL, Triac dimmable, UBA2027X Abstract This application note describes the design of a dimmable Compact Fluorescent Lamp CFL with low dimming level using the UBA2027X.


    Original
    AN10961 UBA2027X UBA2027X UBA2027X. diac advantageS AND DISADVANTAGES PDF

    autotransformer design

    Abstract: fuel injector mosfet control autotransformer MAX1771 LIMITING INRUSH CURRENT mosfet autotransformer APP1198 injector MOSFET autotransformer application transformer current limiter
    Text: Maxim > App Notes > POWER-SUPPLY CIRCUITS Keywords: Off-The-Shelf Transformer Limits Capacitor Inrush Current Jun 22, 1998 APPLICATION NOTE 1198 Off-The-Shelf Transformer Limits Capacitor Inrush Current Energy stored in a high-voltage capacitor activates many applications, including radiological sensors, pulsed


    Original
    com/an1198 MAX1771: AN1198, APP1198, Appnote1198, autotransformer design fuel injector mosfet control autotransformer MAX1771 LIMITING INRUSH CURRENT mosfet autotransformer APP1198 injector MOSFET autotransformer application transformer current limiter PDF

    Untitled

    Abstract: No abstract text available
    Text: The I-Trap" is a version of a Zig-Zag autotransformer that has been designed to provide low zero sequence impedance. The vector addition of three phase fundamental currents will add to zero on a balanced system without harmonics. However, if triplen* harmonic currents


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Questions and Answers fc r Acme's f-Trap Neutral Current Reducer VVhhi is the >Trap ? The I-Trap" is a version of a Zig-Zag autotransformer that has been designed to pro'/ide low zero sequence imped­ ance. What causes a neutral cur­ rent to flow in a balanced


    OCR Scan
    PDF

    T-2-53515-3S

    Abstract: 230v to 12v step down transformer autotransformer
    Text: Questions and Answers about Buck-Boost Transformers 5. What are the most common applications for buck-boost transformers? 1. What is a buck-boost transformer? Buck-boost transformers are small single phase transformers designed to reduce buck or raise (boost) line volt­


    OCR Scan
    PDF