    ASEA current transformer imbd

    Abstract: ASEA EG 20 ASEA relay - unbalance relay ASEA imbd ASEA unbalance relay asea transformer current ASEA RI asea ri 5A relay
    Text: ASEA INFORMATION Unbalance Protection Type RYBIA RK 60-337 E Reg. 7456 for Series capacitors • DESCRIPTION 07 RELAY PROTECTION ASEA capacitor units consist of a number of parallel connected GENERAL elements each of them in series with a built-in fuse. If a short


    OCR Scan
    PDF 53-8/ul? 53-10yuF ASEA current transformer imbd ASEA EG 20 ASEA relay - unbalance relay ASEA imbd ASEA unbalance relay asea transformer current ASEA RI asea ri 5A relay

    automatic change over switch circuit relay

    Abstract: A130 schematic diagram ac circuit breaker
    Text: Info-N o. INFORMATION A lili From /D ate RFR, Aug. 1974 Edition 3 ASEA BROWN BOVERI RK 858-300 E Reg. Page 5651 1 File RK 00-90 E Section 8 ABB Relays Automatic power system restoration equipment type RAAD OUTSTANDING FEATURES ETA The restoration equipment


    OCR Scan
    PDF

    ASEA generator manual

    Abstract: ASEA 34-1 M 160 M 4 asea RK 316 A56A hydropower hydropower plants asea relay RI asea ri relay ASEA E 535 RK 732 - 228
    Text: ASEA IriiO'Mu. RK 549-300 E ' • IINFORMATION R eg. FromrfQato Relay Division . T1TR, September 1977 Edition 1 Paga 5626 1 File RK 00“90 1 Section 5 Frequency relay type TFF 60 o Ability to supervise up to seven frequency levels o Dnder- or overfrequency design


    OCR Scan
    PDF

    Iskra relay

    Abstract: ASEA 5633 iskra PR-55 PR-59 8 pin relay base 11 pin relay base PR41C diode 119 asea type ir PR59
    Text: ASEA INFORMATION Info-Na. RK 119-300 E FrontfDate fwg. Relay Division RFR, June 1977 Edition 1 5633 1 File RK 00-90 E Section 1 Supersedes RK. 10-312 E Pag a Auxiliary relay type PR GENERAL Auxiliary relay type PR is an electro-mechanical d.c. or a.c- relay. Its primary application is industrial automatic equip­


    OCR Scan
    PDF kS--56- Iskra relay ASEA 5633 iskra PR-55 PR-59 8 pin relay base 11 pin relay base PR41C diode 119 asea type ir PR59

    RTXP 18 depth

    Abstract: RTXP 18 ASEA RVAB RXM51 COMBITEST 010-DA ASEA RVAB 71 asea rvab 60MF-N RTXh 24
    Text: ASEA Single-phase thermal overload relay This relay is used to prevent detrim ental heating of 3 machine, transform er 01cable when subjected to overload. Rag. IrB de m ark Catalogue RK 65-27 E Edition 1 May 1975 File R Part 1 cIôîmTbTï F L E X ASEA Design


    OCR Scan
    PDF 010-BA 080-BA 010-DA 19E2-11 RTXP 18 depth RTXP 18 ASEA RVAB RXM51 COMBITEST ASEA RVAB 71 asea rvab 60MF-N RTXh 24

    EARTH LEAKAGE RELAY

    Abstract: ASEA AUTO RECLOSURE recloser razfe recloser RAZOG ABB RXIDF ABB RAAAE RXIDF 2H ABB RELAY - RXM ABB RELAY RXM
    Text: Info-No. 4 1 I I I I f M P I INFORMATION P RK 851-303 E From/Date Reg. RFR, August 19S2 Edition 2 ASEA BROWN BOVERI A B B Relays Page 5651 1 Replaces cat.: RK 85-15 E and RK 85-17 E RECLOSING RELAY TYPE RAAAE Single shot three-phase reclosure Fig 1. Reclosing relay RAAAE


    OCR Scan
    PDF 5B-101 7B-I01 EARTH LEAKAGE RELAY ASEA AUTO RECLOSURE recloser razfe recloser RAZOG ABB RXIDF ABB RAAAE RXIDF 2H ABB RELAY - RXM ABB RELAY RXM

    asea RRME

    Abstract: rk 14 1 asea sv RK 271 005 022B 025B RRM17 51T7 RRME rk 03 u 3K136
    Text: C a t a lo g u e RK 13-5 E Indlcators type RSP and RRSP T-ypn RRSP Jn p lu g -J n tfB B i-g n March 1970 E d lilo n t f7236<k ASEA ASEA Contents Qaneral Design and mode of operation Versions and mounting Maintenance Technical data and Cat. Nos. Ordering particulars


    OCR Scan
    PDF RK13-5E asea RRME rk 14 1 asea sv RK 271 005 022B 025B RRM17 51T7 RRME rk 03 u 3K136

    ASEA RELAY

    Abstract: 5651
    Text: Info-No. ASEA Relay Division INFORMATION RK 853-300 E From/Date Reg. RFR, February 1978 Edition 1 5651 1 File RK 00-90 E Section 8 Page Reclosing relay type RAABC For lines with overcurrent and earth-fault protections. One or two reclosing attempts. o Intended for use together with delayed overcurrent


    OCR Scan
    PDF S-721 ASEA RELAY 5651

    ib101

    Abstract: ABB B50 asea pin terminal RTXG RX1g 21 RX1G 2 1B92 ASEA EG 20 panel and cubicles catalogue RTXP 18 ASEA cubicles catalogue
    Text: 6917 0500-AA »543 *2-0« A IM P mto-No. INFORMATION RK 924-100 E ASEA BROWN b o v e r i From/D«to ABB Relays RFR, September 1980 5600 1 Edition 3 File RK 00-90 Section 9 Rag. Pag* Item designation for relays, equipment frames and cubicles RA .2.D 25.101.119


    OCR Scan
    PDF

    BROWN BOVERI Relay manual

    Abstract: rxnaa ABB RELAY - RAAAM BROWN BOVERI 10 BROWN BOVERI DM relay ABB RXNAC ABB RAAAM rxnaa 4 BROWN BOVERI aca 11 CL25
    Text: Info-No. INFORMATION From /Date asea b ro w n b o v e ri \ RFR, February 1982 Edition 1 ABB Relays RK 862-302 E Reg. Page 5891 1 Replaces Cat. RK 86-11 E Synchro-check relay type RASC o Used for controlled connection of parts of a network th at is already interconnected.


    OCR Scan
    PDF 001-AC 001-BC BROWN BOVERI Relay manual rxnaa ABB RELAY - RAAAM BROWN BOVERI 10 BROWN BOVERI DM relay ABB RXNAC ABB RAAAM rxnaa 4 BROWN BOVERI aca 11 CL25

    Iskra relay

    Abstract: Iskra relay crt 50 iskra diode ISKRA CRT50
    Text: Info-No. ASEA INFORMATION From /Date RFR, Dec. 1975 Edition 1 R e l a y D iv is io n RK 319-300 E Reg. Page 5632 1 File RK 00-90 E Section 3 Time-lag relay type CRT 50 GENERAL a917 0500-A 9543 82-03 Time-lag relay type CRT 50 is a static relay, suitable for


    OCR Scan
    PDF S-721 Iskra relay Iskra relay crt 50 iskra diode ISKRA CRT50

    MR 4710

    Abstract: RTXP 18 ASEA RXIDE 0022-AA rk 12 e RXIDE43 overcurrent relay inverse normal curves rk 651 25D1 asea time-lag relay RI
    Text: ASEA Catalogue RK 65-13 E Edition 1 Fil« » , Part 1 ClOlMiBll iFlLlElXÍ Two or three-phase timeovercurrent protective relays Contarli* General Design Setting Diagrams Installation Ordering Reference publications Cl oj CJ For machines, transformers, cables and


    OCR Scan
    PDF 21-1G 9Z-10 S-721 MR 4710 RTXP 18 ASEA RXIDE 0022-AA rk 12 e RXIDE43 overcurrent relay inverse normal curves rk 651 25D1 asea time-lag relay RI

    BROWN BOVERI Relay manual

    Abstract: ABB RXNAC RTXH18 rtxH 24 Relay RXM block diagram of transformer with breaker V101 ABB RELAY - RXM 220v ac circuit breaker RXME ABB
    Text: Info-No. INFORMATION From/Date ASEA B R O W N BOVERI add Rq Iowc ABB Relays RFR, April 1982 Edition 1 RK 862-303 E Reg. Page 5891 1 Replaces Cat. RK 86-12 E Voltage check relay type RASP o Used for energizing a network section after checking the voltage on both sides of the energizing circuit breaker.


    OCR Scan
    PDF 006-AB BROWN BOVERI Relay manual ABB RXNAC RTXH18 rtxH 24 Relay RXM block diagram of transformer with breaker V101 ABB RELAY - RXM 220v ac circuit breaker RXME ABB

    rxma1

    Abstract: RXK026 DATA ABOUT RELAY SWITCH 8517E MR Relay ASEA ABG 10 S651 about the dc relay ABG10 rxme1
    Text: Catalogue RK 85-17 E ASEA Edition 1 April 1978 Rie R Part 1 Reclosing relay type RAAAC For line^ wsth delayed overemfent protection Single-shut reclosing Intended to be used together with delayed overcurrent relay with or without starting contact. The starting


    OCR Scan
    PDF 03S23) RXK026 RXTNF11 RK31-14E SK63-1 S-721 rxma1 DATA ABOUT RELAY SWITCH 8517E MR Relay ASEA ABG 10 S651 about the dc relay ABG10 rxme1

    razfe recloser

    Abstract: TT214 BROWN BOVERI Relay manual 220V 17A Relay RAZOG Brown Boveri itl 12-1 BROWN BOVERI DISTANCE RELAYS BROWN BOVERI AUXILIARY RELAY RXIDF 2H asea RK 216
    Text: A » m m 1 » Info-No. » INFORMATION RK 851-304 E ASEA B R O W N BOVERI From/Date Reg. ABB Relays ^ R’ December 1982 5651 Edition 1 Page 1 R eplaces C atalo gue RK 85-18 E RECLOSING RELAY TYPE RAAAF Two delayed th re e -p h a se reclosing a t te m p t s


    OCR Scan
    PDF 277-DB 017-DB razfe recloser TT214 BROWN BOVERI Relay manual 220V 17A Relay RAZOG Brown Boveri itl 12-1 BROWN BOVERI DISTANCE RELAYS BROWN BOVERI AUXILIARY RELAY RXIDF 2H asea RK 216

    asea

    Abstract: ASEA PLUG IN RELAY RXEB 101AD 101-AD
    Text: ASEA Catalogue RK 42-12 E Edition 1, June 1971. Over and undervoltage relays type RXEB Measuring voltage relays for d.c. o r a.c. Are protected against voltage transients Have high resetting ratios; > 9 7 % and < 1 0 3 % respectively. d.c. versions polarity dependent;


    OCR Scan
    PDF 101-AD 001-DM 101-DM asea ASEA PLUG IN RELAY RXEB 101AD

    cubicles catalogue

    Abstract: RAKZA 004-AA 92-10E ASEA PLUG IN RELAY RXKB 1
    Text: ASEA Catalogue RK 65-52 E Edition 1 Septem ber 1977 File Ft, Part 1 Three-phase impedance-measuring protective relay type RAKZA * Circular impedance characteristic * Adjustable operating time * Operating value adjustable in stages of 3 - 5 % in the range of 4—154 f!


    OCR Scan
    PDF RK651 21-AA 92-10E RK33-11 S-721 cubicles catalogue RAKZA 004-AA 92-10E ASEA PLUG IN RELAY RXKB 1

    RAZOA

    Abstract: distance relay 614-105E ASEA relay - RAKZB ASEA relay - RAzoa RQAA030 rakzb rtxH 24 RK614 614-100
    Text: ASEA Catalogue RK 61 -20 E Edition 1 1 3 8 1 -0 4 File R Part i Distance relay type RAZOA •Used for cables and overhead t<ansinisslon lines Three-phase switched-scheme relay of compact $iatic design Overcurnent start Healthy phase polarisation and memory


    OCR Scan
    PDF S-721 RAZOA distance relay 614-105E ASEA relay - RAKZB ASEA relay - RAzoa RQAA030 rakzb rtxH 24 RK614 614-100

    rxtta-2

    Abstract: 3x110V
    Text: f lt k f v Catalogue RK 43-12 E ASEA Edition 1 Three-phase undervoltage relay type RXOTB 23 Intended among other things for con­ trol equipments and thyristor conver­ tors Operates tor symmetrical and asym­ metrical voltage drops and for phase failures


    OCR Scan
    PDF 3x380 3x220 3x190 3x110 /3x38V rxtta-2 3x110V

    RK511

    Abstract: RXPE4 RAEPA rxtcb1 RXKB-1 B762 rxsf-1 RXSF1 RTXP1 P03S-BA
    Text: ASEA Catalogue RK 65-53 E Edition 1 Directional earth-fault relay type RAEPA for solidly earthed networks • high sensitivity, even at polarising voltages down to 0.5 % of rated voltage • built-in filter for suppressing har­ monics • static directional current relay requir­


    OCR Scan
    PDF RKS2-10 0032-AA RK653 001-AA RK511 RXPE4 RAEPA rxtcb1 RXKB-1 B762 rxsf-1 RXSF1 RTXP1 P03S-BA

    ASEA EG 10 contactor

    Abstract: asea time-lag relay RI RRCEA tap control transformer RAYA asea contactors asea EG contactor rCEA relay driver circuit using transistor circuit diagram of three phase automatic changeover switch 3604 relay
    Text: Catalogue RK 82-2 E ASEA Edition 2 July 1973 File R, part 2 Voltage regulating relay type RCEA For transformers with on-load tap-changers Solld-etate components throughout except for the electromechanical output relays which give switching impulses. The regulating value is continuously vari­


    OCR Scan
    PDF

    asea over current relay rk 427

    Abstract: asea over current relay Rxotf rk73-13e asea EG 160 RK 211 037 600020 4S12C asea relay RK732
    Text: Catalogue RK 43-11 E ASEA Edition 1 Three-phase overvoltage and undervoltage relay Type RXOTF 4 Operates both as an overvoltage and an undervoltage relay for single, two and three-phase voltage variations in three-phase networks up to 380 V. Infinitely variable operating values:


    OCR Scan
    PDF 037-AD 301-AD. RK73-13E S-721 asea over current relay rk 427 asea over current relay Rxotf asea EG 160 RK 211 037 600020 4S12C asea relay RK732

    RXTLA 1

    Abstract: 7417 radhd transformer calculation formula calculation of transformer differential relay setting VOLTAGE DEPENDENT RESISTOR test VOLTAGE DEPENDENT RESISTOR asea type ir NON-LINEAR RESISTOR 005-DA
    Text: Ate A5E*BROWNfeCS'.'E* INFORMATION li'iFo-No, KK. 646-302 E From,''Date Reg. RFR, April 1976 Edition 1 ABB Relays PagS 7417 1 File RK 00-90 E Section 6 RADHD used as high-imped ante, restricted fi earth-fault relay _ t_ _ Fig. 1. ASEA, 721 BJ VitSlerJs


    OCR Scan
    PDF 005-operating 005-AA 007-AA RXTLA 1 7417 radhd transformer calculation formula calculation of transformer differential relay setting VOLTAGE DEPENDENT RESISTOR test VOLTAGE DEPENDENT RESISTOR asea type ir NON-LINEAR RESISTOR 005-DA

    ASEA ABG 10

    Abstract: RAZOG SELECTOR SWITCH ASEA ABG L DISTANCE RELAY CATALOGUE SK 63-1 E ABG 10 SK 63-1 E AUXILIARY CONTACT RELAY Rxme 2 ba 8515
    Text: ASEA Catalogue RK 85-15 E Edition 1 Aprii 1978 Fila R, Part 1 Reciosing relay type RAAAG For lines with distance protection Single shot three-phase reclosing » Intended for use together with dis- • A counter registers tha number of lance relay type RAZOG but can norshots


    OCR Scan