Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    APPLICATION OF CLAMP METER Search Results

    APPLICATION OF CLAMP METER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCKE812NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, Fixed Over Voltage Clamp, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE812NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    GP-IE156327SS-006 Amphenol Cables on Demand Amphenol GP-IE156327SS-006 Shielded GPIB Cable (IEEE-488 Cable) w/ Stackable GPIB Connectors (24-pin M/F) 6m Datasheet
    GP-IE156327SS-003 Amphenol Cables on Demand Amphenol GP-IE156327SS-003 Shielded GPIB Cable (IEEE-488 Cable) w/ Stackable GPIB Connectors (24-pin M/F) 3m Datasheet
    GP-IE156327SS-000.5 Amphenol Cables on Demand Amphenol GP-IE156327SS-000.5 Shielded GPIB Cable (IEEE-488 Cable) w/ Stackable GPIB Connectors (24-pin M/F) 0.5m Datasheet

    APPLICATION OF CLAMP METER Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    SMP-02V-BC

    Abstract: PVC 90A material clamp meter circuit diagram 90-Amp PVC 90A material datasheet AWG18 AWG22 TU10P-90A clamp-on sensor
    Text: Topstek AC Current Sensor TU10P-90A AC Current Transducers TU10P-90A Features and Applications iAccurate AC current monitoring/measuring device iFast clamp-on application on existing switchboard wire iExcellent linearity of the output voltage over a wide input range


    Original
    PDF TU10P-90A 90Amp 120ARMS 150kHz 60sec 500VDC UL94V0 AWG22, AWG18 SMP-02V-BC PVC 90A material clamp meter circuit diagram 90-Amp PVC 90A material datasheet AWG22 TU10P-90A clamp-on sensor

    SMP-02V-BC

    Abstract: clamp meter circuit diagram AWG22 UL94V0 PVC TU24P-250A AWG18 clamp-on 1000v 250A connector
    Text: Topstek AC Current Sensor TU24P-250A TU24P-250A Features and Applications iAccurate AC current monitoring/measuring device iFast clamp-on application on existing switchboard wire iExcellent linearity of the output voltage over a wide input range iFerrite core ensuring fast response time and low phase lag


    Original
    PDF TU24P-250A 250Amp 50mARMS 250ARMS 50Hz/60Hz) 360ARMS 100kHz 60sec 500VDC SMP-02V-BC clamp meter circuit diagram AWG22 UL94V0 PVC TU24P-250A AWG18 clamp-on 1000v 250A connector

    clamp meter circuit diagram

    Abstract: AWG18 AWG22 TU16P-150A
    Text: Topstek AC Current Sensor TU16P-150A TU16P-150A Features and Applications iAccurate AC current monitoring/measuring device iFast clamp-on application on existing switchboard wire iExcellent linearity of the output voltage over a wide input range iFerrite core ensuring fast response time and low phase lag


    Original
    PDF TU16P-150A 150Amp 10mARMS 150ARMS 50Hz/60Hz) 300ARMS 150kHz 60sec 500VDC clamp meter circuit diagram AWG18 AWG22 TU16P-150A

    PAX2S000

    Abstract: PAXP0000 9pin D-connector modbus PAXP0010 PAXS0000 PAXCDC20 PAXCDS20 PAX2D000 PAXCDS10
    Text: 1492-2012.qxp:QuarkCatalogTempNew 8/31/12 4:26 PM Page 1492 INTERCONNECT TEST & MEASUREMENT 16 Panel Meters DP Series, 1/8 DIN Digital Panel Meters RoHS The DP5 Panel Meters offer many features and performance capabilities to suit a wide range of industrial applications. These meters are available in three different models to handle various


    Original
    PDF DP5D0000 DP5P0000 DP5T0000 DP5P0010* DP5D0010* RS232 PAXLBK10 PAXCDC30 PAXCDC40 PAX2S000 PAXP0000 9pin D-connector modbus PAXP0010 PAXS0000 PAXCDC20 PAXCDS20 PAX2D000 PAXCDS10

    Fluke Multimeter repair

    Abstract: Multimeter fluke 23 Fluke 45 Multimeter fluke 70 FLUKE 23 Fluke 45 datasheet FLUKE 75 FLUKE 87 Multimeter fluke 114 FLUKE 75 multimeter
    Text: Instruction Sheet i400 AC Current Clamp Introduction The Model i400 hereafter called “the Current Clamp” is an ac current clamp that outputs 1 mA/A via safety-shrouded banana plugs; it is designed to extend the measuring capability of an ac current meter to 400 A.


    Original
    PDF 1-888-44-FLUKE 1-800-36-FLUKE 1-888-99-FLUKE Fluke Multimeter repair Multimeter fluke 23 Fluke 45 Multimeter fluke 70 FLUKE 23 Fluke 45 datasheet FLUKE 75 FLUKE 87 Multimeter fluke 114 FLUKE 75 multimeter

    HIOKI 3287

    Abstract: P1201A crest audio pro 8200
    Text: 2014 Electrical Measuring Instruments General Catalog Recorders Data loggers Power Meters LCR Testers Battery Testers Current Probes Clamp Sensors Recorders / Data Loggers / Remote Measurement System / Component Measuring Instruments / Signal Sources / Safety Standards Measuring Instruments


    Original
    PDF 0001E52-3ZE-15K HIOKI 3287 P1201A crest audio pro 8200

    digital AC clamp meter

    Abstract: EMF-1394 1352P ndm diode IDM-610 IEC60651 tester SCR Digital Frequency Meter with LCD Display digital sensor tester bargraph LCD
    Text: 103-2012:QuarkCatalogTempNew 8/13/12 4:37 PM Page 103 1 Sound and Light Meters, Testers and Multimeters TEST & MEASUREMENT Sound Meter — 1352P Digital Light Meter — ILM 1335 Designed to meet the requirements of safety, health, industrial safety officers and


    Original
    PDF 1352P IEC61010-1 digital AC clamp meter EMF-1394 ndm diode IDM-610 IEC60651 tester SCR Digital Frequency Meter with LCD Display digital sensor tester bargraph LCD

    Mbus master 250 slave circuit

    Abstract: mbus master circuit
    Text: NCN5151 Wired M-BUS Slave Transceiver with Low Power Mode Support Description http://onsemi.com The NCN5151 is a single−chip integrated slave transceiver for use in two−wire Meter Bus M−BUS slave devices and repeaters. The NCN5151 reuses the NCN5150 features and adds two low


    Original
    PDF NCN5151 NCN5150 NCN5151/D Mbus master 250 slave circuit mbus master circuit

    8 lcd digit counter

    Abstract: 417 TRANSISTOR 3.5 digit 7 segment lcd display d 417 transistor LCD FREQUENCY COUNTER MODULE CUB5B000 cub5rly0 C48CS C48C C48TS104
    Text: 1488-2012.qxp:QuarkCatalogTempNew 8/31/12 4:14 PM Page 1488 ENCLOSURES INTERCONNECT TEST & MEASUREMENT 16 Panel Meters CUB5 Series, Dual Counter/Rate Meters and Timers C UL R US LISTED RoHS The CUB5 is a miniature 8-digit dual counter and rate indicator. The CUB5 provides up to three functions in a single display package. The display can be toggled either


    Original
    PDF PAXLC600 PAXLC800 4X/IP65 PAXLC600 8 lcd digit counter 417 TRANSISTOR 3.5 digit 7 segment lcd display d 417 transistor LCD FREQUENCY COUNTER MODULE CUB5B000 cub5rly0 C48CS C48C C48TS104

    Untitled

    Abstract: No abstract text available
    Text: NCN5151 Wired M-BUS Slave Transceiver with Low Power Mode Support Description http://onsemi.com The NCN5151 is a single−chip integrated slave transceiver for use in two−wire Meter Bus M−BUS slave devices and repeaters. The NCN5151 reuses the NCN5150 features and adds two low


    Original
    PDF NCN5151 NCN5151 NCN5150 NCN5151/D

    Untitled

    Abstract: No abstract text available
    Text: ZES Sensors and Accessories for precision power meters LMG series 90/310/95/450/500 version:28. May 2014 ZES current and voltage sensors and accessories This data book is the technical dokumentation of the current and voltage sensors from ZES ZIMMER Electronic Systems GmbH to enlarge the measuring ranges of the power meters


    Original
    PDF LMG500

    LED Clock Display dual

    Abstract: PAXCDS10 PAXCDL10 PAXCDS30 Digital Alarm Clock LED display PAXCDC10
    Text: 1489-2012.qxp:QuarkCatalogTempNew 8/31/12 4:17 PM Page 1489 16 Panel Meters RoHS The PAX Lite Counter/Rate Meter is a 6-digit single or dual counter and rate indicator. The PAXLCR provides up to three functions in a single display package. The display can be toggled either in manually or automatically between the rate and counter displays. The counters may be programmed for the one of eight different count modes.


    Original
    PDF RS232 PAXLBK10 PAXCDC30 PAXCDC40 PAXUSB00 PAXCDS30 RS485 LED Clock Display dual PAXCDS10 PAXCDL10 PAXCDS30 Digital Alarm Clock LED display PAXCDC10

    Untitled

    Abstract: No abstract text available
    Text: ES51929 6000 Counts Smart DMM Features Application  6000 counts LCD display  Smart digital multi-meter  3V DC power supply  Smart clamp meter  Conversion rate: 3 times/s voltage mode  Full automatic measurement: General description *Voltage/Current: AC/DC auto scanning


    Original
    PDF ES51929 ES51929 SEG01 SEG02 SEG03 SEG04 SEG05 SEG06 SEG07 SEG08

    NCN5150-D

    Abstract: NCN5150 D meter bus NCN5150 NQFP-20 mbus master circuit wired m-bus
    Text: NCN5150 Wired M-BUS Slave Transceiver Description The NCN5150 is a single-chip integrated slave transceiver for use in two-wire Meter Bus M-BUS slave devices and repeaters. The transceiver provides all of the functions needed to satisfy the European Standards EN 13757−2 and EN 1434−3 describing the


    Original
    PDF NCN5150 NQFP-20 SOIC-16 NCN5150/D NCN5150-D NCN5150 D meter bus mbus master circuit wired m-bus

    meter bus

    Abstract: No abstract text available
    Text: NCN5150 Wired M-BUS Slave Transceiver Description The NCN5150 is a single-chip integrated slave transceiver for use in two-wire Meter Bus M-BUS slave devices and repeaters. The transceiver provides all of the functions needed to satisfy the European Standards EN 13757−2 and EN 1434−3 describing the


    Original
    PDF NCN5150 NQFP-20 SOIC-16 NCN5150/D meter bus

    Mbus master 250 slave circuit

    Abstract: meter bus wired m-bus free mbus master
    Text: NCN5150 Product Preview Wired M-BUS Slave Transceiver Description The NCN5150 is a single−chip integrated slave transceiver for use in two−wire Meter Bus M−BUS slave devices and repeaters. The transceiver provides all of the functions needed to satisfy the


    Original
    PDF NCN5150 NQFP-20 NCN5150/D Mbus master 250 slave circuit meter bus wired m-bus free mbus master

    cushcraft r6000

    Abstract: No abstract text available
    Text: ASSEMBLY AND INSTALLATION INSTRUCTIONS R6000 6, 10, 12, 15, 17, 20 Meters COMMUNICATIONS ANTENNAS 951472 2/99 R6000 WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT IN DEATH, OR SERIOUS INJURY. DO NOT INSTALL THIS ANTENNA WHERE THERE IS ANY POSSIBILITY OF CONTACT WITH HIGH VOLTAGE OR ARC-OVER FROM POWER CABLES


    Original
    PDF R6000 R6000 cushcraft r6000

    Untitled

    Abstract: No abstract text available
    Text: 296 Digital Clamp-on Meter Amp Plus Instruction Manual TABLE OF CONTENTS A. INTRODUCTION A. INTRODUCTION 1. Congratulations .3 2. Product Description .3 3. Declaration of Conformity .4 1. Congratulations!!


    Original
    PDF L296M 10KHz 001KHz

    1758-RTU202

    Abstract: 199-FSMA9 IN4004 diode SD499 bulletin 700 type n electromagnetism notes for degree 199-FSMA10 1758-FLO302 relay 48v dc machine hourly monitoring
    Text: DataSite Electronic Flow Meter and Remote Terminal Unit Hardware User Manual Catalog Numbers 1758-FLO301, 1758-FLO302, 1758-RTU201, 1758-RTU202 Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the


    Original
    PDF 1758-FLO301, 1758-FLO302, 1758-RTU201, 1758-RTU202) 1758-UM001B-EN-P 1758-UM001A-EN-P 1758-RTU202 199-FSMA9 IN4004 diode SD499 bulletin 700 type n electromagnetism notes for degree 199-FSMA10 1758-FLO302 relay 48v dc machine hourly monitoring

    R6000 equivalent

    Abstract: cushcraft r6000 nylock nut
    Text: ASSEMBLY AND INSTALLATION INSTRUCTIONS R6000 6, 10, 12, 15, 17, 20 Meters COMMUNICATIONS ANTENNAS 951472 8/98 R6000 WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT IN DEATH, OR SERIOUS INJURY. DO NOT INSTALL THIS ANTENNA WHERE THERE IS ANY POSSIBILITY OF CONTACT WITH HIGH VOLTAGE OR ARC-OVER FROM POWER CABLES


    Original
    PDF R6000 R6000 R6000 equivalent cushcraft r6000 nylock nut

    71M6515

    Abstract: 71M6515 71M6513 6513 71M6511 71M6513 71M651X
    Text: 71M651x Energy Meter IC APPLICATION NOTE AN_651X_019 MAY 2005 Interfacing to the RX Pin of the 6511, 6513 and 6515 Due to unique circuitry on the RX input, its behavior is slightly different from the other digital inputs of the 651X family of metering ICs.


    Original
    PDF 71M651x 71M6511, 71M6513 71M6515 71M6515 71M6513 6513 71M6511 71M651X

    12v relay 6 pin diagram

    Abstract: 12v relay 6 pin 12V 5 pin RELAY PIN DIAGRAM
    Text: SEMICONDUCTOR KIA6905F TECHNICAL DATA Bidirectional Relay Driver IC 200mA Bidirectional Relay Driver IC KIA6905F is the bidirectional relay driver IC for control latching relay output current, static power consumption characteristics, can be widely used in the production of the smart meter industry and other such relay


    Original
    PDF KIA6905F 200mA KIA6905F 200mA 12v relay 6 pin diagram 12v relay 6 pin 12V 5 pin RELAY PIN DIAGRAM

    Untitled

    Abstract: No abstract text available
    Text: ALTAIR04-900 Off-line all-primary-sensing switching regulator Datasheet - production data • Low standby consumption • Overcurrent protection against transformer saturation and secondary diode short-circuit • SO16N package Applications SO16N • SMPS for energy metering


    Original
    PDF ALTAIR04-900 SO16N SO16N ALTAIR04-900 DocID18211 ALTAIR04-900TR

    MN7000

    Abstract: No abstract text available
    Text: ASSEMBLY AND INSTALLATION INSTRUCTIONS R7000 10, 12, 15, 17, 20, 30, 40 Meters C O R P O R A T I O N 951465 10/96 R7000 WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT IN DEATH, OR SERIOUS INJURY. DO NOT INSTALL THIS ANTENNA WHERE THERE IS ANY POSSIBILITY OF CONTACT WITH HIGH VOLTAGE OR ARC-OVER FROM POWER CABLES


    Original
    PDF R7000 R7000 MN7000