Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    AIR FLOW DETECTOR APPLICATION Search Results

    AIR FLOW DETECTOR APPLICATION Result Highlights (2)

    Part ECAD Model Manufacturer Description Download Buy
    D1U54T-M-2500-12-HB4C Murata Manufacturing Co Ltd 2.5KW 54MM AC/DC 12V WITH 12VDC STBY BACK TO FRONT AIR Visit Murata Manufacturing Co Ltd
    Flower-Reference-Design Renesas Electronics Corporation Flower Reference Design Featuring 4.5V - 18V Input Switching Regulator Visit Renesas Electronics Corporation

    AIR FLOW DETECTOR APPLICATION Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    AIR FLOW DETECTOR

    Abstract: air flow detector sensor NRP-345 wind velocity sensor
    Text: Air Flow Detector D6A-N Air Flow detector specifically to detect clogged conditions in air filters on servers and other types of computer equipment • Detects the clogged conditions of air filters more efficiently than a conventional time totalling meter


    Original
    PDF NRP-345 AIR FLOW DETECTOR air flow detector sensor wind velocity sensor

    QBM81-3

    Abstract: QBM81-10 Siemens QBM81 QBM81-5 CA1N1589E Differential Pressure siemens 604.15011 siemens QBM81-3 pg11 cable gland IEC529
    Text: 1 Differential Pressure Detector 552 QBM81-. for monitoring of air pressure Differential pressure detector for ventilation and air conditioning systems • For monitoring of air filters, air flow, fan belts • For monitoring of pressure in clean rooms, kitchens etc.


    Original
    PDF QBM81-. CA1N1552E QBM81-3 QBM81-10 Siemens QBM81 QBM81-5 CA1N1589E Differential Pressure siemens 604.15011 siemens QBM81-3 pg11 cable gland IEC529

    Untitled

    Abstract: No abstract text available
    Text: SL-DA4R Series Analog Addressable Duct Smoke Detectors Hi-Temp, Low-FLow & No-Tools Description The SL-DA4R Series Smoke Duct Detector is the latest analog addressable innovation for early detection of smoke and products of combustion present in air moving


    Original
    PDF STN-10 24VAC 24VDC

    Untitled

    Abstract: No abstract text available
    Text: SL-DAA Series Analog Addressable Duct Detectors Hi-Temp, Low-FLow & No-Tools Description The SL-DAA Series Smoke Duct Detector is the latest analog addressable innovation for early detection of smoke and products of combustion present in air moving through


    Original
    PDF STN-10

    Untitled

    Abstract: No abstract text available
    Text: SL-2000 Series Duct Smoke Detectors Hi-Temp, Low-Flow and No-Tools Description The SL-2000 Series Smoke Duct Detector is the latest innovation for early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial, Industrial, and Residential applications. The


    Original
    PDF SL-2000 SL-2000-N WP-2000 TG-2000

    A5053GM

    Abstract: No abstract text available
    Text: SS-PD and SS-PDR Features Intelligent Low-Flow Photoelectric Duct Smoke Detectors • Air velocity rating from 100 to 4,000 feet per minute 0.5 to 20.32 m/sec. . • Patented telescopic sampling tube. SS-PD • Easily accessible code wheels for addressing detector.


    Original
    PDF CS-2463 CS-2463 A5053GM

    abb fid

    Abstract: flame detector burner PGC2009 FID detector CE-EX pressure reducing valve air transistor NEC D 586 AIR FLOW DETECTOR applications ABB 12 30 01 ATEX flame detector
    Text: General Specifications PGC2009 E2 Fast Temperature Programmed Process Gas Chromatographs Application Usage The PGC2009 E2 Fast Temperature Programmed Gas Chromatograph GC uses component separation to analyze liquid samples and performs specialty analysis for separation of wide boiling point range compounds. The analyzer


    Original
    PDF PGC2009 BUASC1A-16-0609 abb fid flame detector burner FID detector CE-EX pressure reducing valve air transistor NEC D 586 AIR FLOW DETECTOR applications ABB 12 30 01 ATEX flame detector

    PGC2000

    Abstract: gas chromatograph gas analytical PGC-2000 flame detector 001psig
    Text: General Specifications PGC2000 E2 Series Process Gas Chromatographs Application Usage The Process Gas Chromatograph PGC2000 E2 Series uses columns to separate gas or liquid samples prior to measurement. The analyzer operates unattended, automatically sampling and analyzing


    Original
    PDF PGC2000 BUASC1A-6-609 gas chromatograph gas analytical PGC-2000 flame detector 001psig

    electronic oven control

    Abstract: oven heat controller OVEN flame detector burner ATEX flame detector AIR FLOW DETECTOR material PGC2005 BURNER DETECTOR FLAME 11ft3
    Text: General Specifications Process Gas Chromatographs PGC2005 Temperature Programmed GC Application Usage Specialty analysis for separation of wide boiling range compounds. The PGC2005 “Temperature Programmed” Gas Chromatograph uses component separation to analyze gas or liquid samples. The


    Original
    PDF PGC2005 PGC2005 BUASC1A10 electronic oven control oven heat controller OVEN flame detector burner ATEX flame detector AIR FLOW DETECTOR material BURNER DETECTOR FLAME 11ft3

    yamatake magnetic flow meter

    Abstract: magnetic flow meter Yamatake Pt 100 sensor connection yamatake yamatake FL JIS10K Yamatake air flow meter calorimeter sensor model yamatake magnetic flow meter Yamatake converter
    Text: No. SS2-MCM100-0100 Electromagnetic calorimeter Model MCM10A OVERVIEW The Yamatake model MCM10A is a custody transfer meter used to measure the calorie consumption of air conditioning systems in buildings or shopping malls or it can be used in district heating/cooling applications.


    Original
    PDF SS2-MCM100-0100 MCM10A MCM10A 30max yamatake magnetic flow meter magnetic flow meter Yamatake Pt 100 sensor connection yamatake yamatake FL JIS10K Yamatake air flow meter calorimeter sensor model yamatake magnetic flow meter Yamatake converter

    ZBD42203

    Abstract: SCH40 5K80A JIS10K NSH4 blow down valve gas detector 200VA SUS304 15ASGP
    Text: IN-SITU ZIRCONIA OXYGEN ANALYZER <ZIRCOMAT-P> DATA SHEET This oxygen analyzer is used to continuously measure oxygen concentration in combustible exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion monitoring and control. The detector ZFK used with the analyzer is directly


    Original
    PDF 10K65ARF) ZBD42203 SCH40 5K80A JIS10K NSH4 blow down valve gas detector 200VA SUS304 15ASGP

    555 FAN CONTROL BY USING THERMISTOR

    Abstract: DELTA fan 12v dc soft start motor fan 555 FAN CONTROL PAN 3504 12v brushless motor fan cpu PWM USING IC 555 TIMER buzzer 48vdc BUZZER WATERPROOF delta sensflow
    Text: Application Introduction instruments and equipment gives Delta very strong design capability. Advanced engineering equipment such as Star-LT simulation software, computerized CNC machines, semi-anechoic chambers and wind tunnels are used to develop high performance, low


    Original
    PDF ISO-9001 TS-16949 D-59494, 555 FAN CONTROL BY USING THERMISTOR DELTA fan 12v dc soft start motor fan 555 FAN CONTROL PAN 3504 12v brushless motor fan cpu PWM USING IC 555 TIMER buzzer 48vdc BUZZER WATERPROOF delta sensflow

    PWM 12V fan speed control ic 555

    Abstract: DELTA fan 555 FAN CONTROL BY USING THERMISTOR 555 FAN PWM fan speed control using thermistor PWM 555 FAN CONTROL soft start circuit 555 timer buzzer 48vdc BUZZER WATERPROOF 555 FAN CONTROL
    Text: Application Introduction instruments and equipment gives Delta very strong design capability. Advanced engineering equipment such as Star-LT simulation software, computerized CNC machines, semi-anechoic chambers and wind tunnels are used to develop high performance, low


    Original
    PDF ISO-9001 TS-16949 D-59494, PWM 12V fan speed control ic 555 DELTA fan 555 FAN CONTROL BY USING THERMISTOR 555 FAN PWM fan speed control using thermistor PWM 555 FAN CONTROL soft start circuit 555 timer buzzer 48vdc BUZZER WATERPROOF 555 FAN CONTROL

    4-20mA transmitter for a bridge type transducer

    Abstract: PT200 Platinum Resistance Temperature Detector pt100 temperature wheatstone PT100 wheatstone bridge example PT200 Platinum RTD reference table PT200 rtd Thermistor hot-wire bridge transducer 4-20ma transmitter silicon diode temperature sensor PT100 thermistor
    Text: APPLICATION BULLETIN Mailing Address: PO Box 11400 • Tucson, AZ 85734 • Street Address: 6730 S. Tucson Blvd. • Tucson, AZ 85706 Tel: 602 746-1111 • Twx: 910-952-111 • Telex: 066-6491 • FAX (602) 889-1510 • Immediate Product Info: (800) 548-6132


    Original
    PDF 4-20mA 4-20mA transmitter for a bridge type transducer PT200 Platinum Resistance Temperature Detector pt100 temperature wheatstone PT100 wheatstone bridge example PT200 Platinum RTD reference table PT200 rtd Thermistor hot-wire bridge transducer 4-20ma transmitter silicon diode temperature sensor PT100 thermistor

    spreeta

    Abstract: spreeta LED ABSTRACT OF AIR FLOW DETECTOR water pumping machine control E121 saline sensor
    Text: Spreeta  Noise and Baseline Drift Minimization Application Brief Number 001 1999 Microcomponents Technology SLYA017A IMPORTANT NOTICE Texas Instruments and its subsidiaries TI reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information


    Original
    PDF SLYA017A SLYA017 spreeta spreeta LED ABSTRACT OF AIR FLOW DETECTOR water pumping machine control E121 saline sensor

    4-20mA transmitter for a bridge type transducer

    Abstract: pt100 with wheatstone bridge instrumentation amp design of a 4-20mA transmitter for a bridge type design of 4-20mA transmitter for bridge type transducer PT200 Platinum Resistance Temperature Detector pt100 temperature wheatstone PT100 wheatstone bridge example silicon diode temperature sensor voltage 0-1v to 4-20mA loop converter with ic pt100 with wheatstone bridge instrumentation amplifier
    Text: APPLICATION BULLETIN Mailing Address: PO Box 11400 • Tucson, AZ 85734 • Street Address: 6730 S. Tucson Blvd. • Tucson, AZ 85706 Tel: 602 746-1111 • Twx: 910-952-111 • Telex: 066-6491 • FAX (602) 889-1510 • Immediate Product Info: (800) 548-6132


    Original
    PDF 4-20mA 4-20mA transmitter for a bridge type transducer pt100 with wheatstone bridge instrumentation amp design of a 4-20mA transmitter for a bridge type design of 4-20mA transmitter for bridge type transducer PT200 Platinum Resistance Temperature Detector pt100 temperature wheatstone PT100 wheatstone bridge example silicon diode temperature sensor voltage 0-1v to 4-20mA loop converter with ic pt100 with wheatstone bridge instrumentation amplifier

    triac driver opto application note

    Abstract: triac snubber calculation 2 amp triac driver opto OPTO TRIAC LIMITING INRUSH CURRENT npn TRIAC RCA ntc 3 phase inrush current limiting mov failure rate mtbf Optocoupler with triac circuits motorola make ntc thermistor
    Text: Order this document by AN1511/D MOTOROLA SEMICONDUCTOR AN1511 APPLICATION NOTE Applications of the MOC2A40 and MOC2A60 Series POWER OPTO ISOLATORS Prepared by: Horst Gempe Discrete Applications Engineering INTRODUCTION Electronic controls of AC power loads based on microprocessor controllers, digital or linear sensor circuits are


    Original
    PDF AN1511/D AN1511 MOC2A40 MOC2A60 2PHX33459P-0 AN1511/D* triac driver opto application note triac snubber calculation 2 amp triac driver opto OPTO TRIAC LIMITING INRUSH CURRENT npn TRIAC RCA ntc 3 phase inrush current limiting mov failure rate mtbf Optocoupler with triac circuits motorola make ntc thermistor

    MA 8910

    Abstract: "PIR wiring diagram PIR datasheet pir detector pir sensor infrared activated device Carlo movement sensor pir 8910 PIR sensor module
    Text: PIR Sensor Type G 8910 2129 • Passive infrared detector PIR • Detects movement by e.g. a person • 2-channel transmitter • Indoor applications • Operating distance: 10 m • Operating angle: 90° • Walk test: LED indication • Channel coding by GAP 1605


    Original
    PDF

    "PIR wiring diagram

    Abstract: PIR datasheet pir detector dupline gap 1605 led air flow detector air detection
    Text: Du line PIR Sensor Type G 8210 1127 Fieldbus Installationbus • Passive infrared detector PIR • Detects movement by e.g. a person • Indoor applications • Operating distance: Max. 6 m • Operating angle: 90° • Walk test: LED indication • Channel coding by GAP 1605


    Original
    PDF

    "PIR wiring diagram

    Abstract: movement sensor pir PIR datasheet pir 5
    Text: Du line PIR Sensor Type G 8110 1127 Fieldbus Installationbus • Passive infrared detector PIR • Detects movement by e.g. a person • Indoor applications • Operating distance: Max. 6 m • Operating angle: 90° • Walk test: LED indication • Channel coding by GAP 1605


    Original
    PDF

    flame detector burner

    Abstract: PGC2000 PGC-2000 carbon monoxide detector ISA gas detector cc valve DETECTOR FLAME Ionization Detectors pgc2000 abb AIR FLOW DETECTOR
    Text: Process Gas Chromatographs PGC2000 Series – Utility Consumptions SUPPORT GAS QUALITY PROCESS GAS CHROMATOGRAPHS INSTRUMENT AIR Instrument air is used for the purge of the electronics housings, the oven heater and to operate the chromatography valves. Normally instrument air should be oil free with a dew point of -40oC.


    Original
    PDF PGC2000 -40oC. 10ppm. BUASC1A14 flame detector burner PGC-2000 carbon monoxide detector ISA gas detector cc valve DETECTOR FLAME Ionization Detectors pgc2000 abb AIR FLOW DETECTOR

    PIR motion sensor light wiring diagram

    Abstract: vehicle Speed detection sensor passive Infrared motion detector motion sensor wiring diagram "PIR wiring diagram pir detector IEC motion detector opus opus transmitter PIR SENSOR IS MOTION SENSOR
    Text: Du line PIR Sensor Type G 8210 1128 Fieldbus Installationbus • Passive infrared detector PIR for ceiling mounting • Detects movement by e.g. a person • Slight motion detection type • Indoor applications • Operating diameter: Max. 6 m • Operating angle: > 90°


    Original
    PDF

    AIR FLOW DETECTOR circuit

    Abstract: LEVEL DETECTOR level gauge for tank
    Text: LIQUID LEVEL DETECTOR LIQUID LEVEL D E TE C T O R daykin LC SERIES ELECTRIC CORPORATION Specifically designed by Daykin to operate on any vented tank This outstanding Level Detector will accurately detect various levels of extremely contaminated liquids or slurry solutions with exceptional


    OCR Scan
    PDF C4-0496 AIR FLOW DETECTOR circuit LEVEL DETECTOR level gauge for tank

    how to interface optocoupler with triac

    Abstract: triac snubber calculation optocoupler MTBF calculation triac dc motor control circuits snubber full bridge SCR opto DRIVER 12 amp triac heat control triac snubber varistor 2 amp triac driver opto MOC2A40
    Text: MOTOROLA SEMICONDUCTOR APPLICATION NOTE AN1511 Applications of the MOC2A40 and MOC2A60 Series POWER OPTO ISOLATORS Prepared by: Horst Gempe Discrete Applications Engineering INTRODUCTION Electronic controls of AC pow er loads based on m icropro­ cessor controllers, digital or linear sensor circuits are


    OCR Scan
    PDF AN1511 MOC2A40 MOC2A60 how to interface optocoupler with triac triac snubber calculation optocoupler MTBF calculation triac dc motor control circuits snubber full bridge SCR opto DRIVER 12 amp triac heat control triac snubber varistor 2 amp triac driver opto