    Abstract: Bernstein SCR 3-W22-3.6-D
    Text: Technical Data Safety Relay Combination Series SCR SCR 4-W22-3.5-D Description Article number 6075111009 Assembly and function function circuit diagram A1 A2 (+) (-) S33 S34 S11S12 S21 S22 13 23 33 41 14 24 34 42 Electr. Fuse Transformer ~ ~ K1 ~ Monitoring Logic


    Original
    PDF 4-W22-3 S33-S34 S11-S12, S21-S22 D-32457 6075111009_EN Bernstein SCR 3-W22-3.6-D

    6075111010_EN

    Abstract: Bernstein SCR 3-W22-3.6-D
    Text: Technical Data Safety Relay Combination Series SCR SCR 4-W22-3.5-SD Description Article number 6075111010 Assembly and function function circuit diagram A1 A2 (+) (-) S33 S34 S11S12 S21 S22 13 23 33 41 14 24 34 42 Electr. Fuse Transformer ~ ~ K1 ~ Monitoring Logic


    Original
    PDF 4-W22-3 S33-S34 S11-S12, S21-S22 D-32457 6075111010_EN Bernstein SCR 3-W22-3.6-D

    s34 diode

    Abstract: S11-S12
    Text: Emergency Stop and Safety Gate Modules MA1B • • • • • • • • • • Safety Category 2 according to EN 954-1 Category 0 Emergency Stop 2 NO safety outputs 1 NO optocoupled NPN auxiliary outputs 24 VCA / VCC power supply Self monitoring Automatic or manual reset


    Original
    PDF SMS-03 S11S12 S21S22 24Vac S11-S12 S33-S34 s34 diode S11-S12

    Safety Modules

    Abstract: NES13D marking s34 NES02D EN1088 S11-S12 b24s en 60204-1
    Text: Safety Modules Emergency Stop and Safety Gate Types NES02D, NES13D • • • • • • • • • • Screw, fixed Safety Category 4 according to EN 954-1 Category 0 Emergency Stop EN 60204-1 2 x 6 A NO safety outputs (NES02D) 3 x 6 A NO safety outputs and 1 x 6 A NC auxiliary output (NES13D)


    Original
    PDF NES02D, NES13D NES02D) NES13D) EN1088. NES02D. NES13D. Safety Modules NES13D marking s34 NES02D EN1088 S11-S12 b24s en 60204-1

    k22s

    Abstract: DC15V
    Text: PSR-SCP- 24-230UC/ESAM4/3X1/1X2 PSR-SPP- 24-230UC/ESAM4/3X1/1X2 Safety Relay for Monitoring EMERGENCY STOP and Safety Door Circuits, With or Without Start Button Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-…- 24-230UC/ESAM4/3X1/1X2 safety relay can


    Original
    PDF 24-230UC/ESAM4/3X1/1X2 24-230UC/ESAM4/3X1/1X2 60204-1/VDE S33-S35: -24-230UC/ESAM 4-230V k22s DC15V

    xps-dme

    Abstract: schema XPS AC XPS-bf schema XPS gh facon A2S22
    Text: XPS-BF FR GB DE 3RVWH GH FRPPDQGH ELPDQXHOOH YQT7AQ 6DIHW\ UHOD\V IRU WZRKDQG FRQWURO =ZHLKDQG6WHXHUJHUlW @p‚€i…r€r‡†ÃÃ9v€r†v‚†ÃÃHh‰r 99 mm 3.89 in …Ã


    Original
    PDF S11-S12, S11-S13) xps-dme schema XPS AC XPS-bf schema XPS gh facon A2S22

    PNOZ X2.7P

    Abstract: 8P,RELAY PILZ pnoz x2.7p pnoz X2.8P PNOZ EXAMPLE CONEXION Pilz door switch pilz 1 esquema pulsador Pilz pnoz x2.8p
    Text: 20954-04 PNOZ X2.7P / PNOZ X2.8P 4 4 4 D Betriebsanleitung GB Operating instructions F Manuel d'utilisation Sicherheitsbestimmungen 4 4 4 E Instrucciones de uso I Istruzioni per l`uso NL Gebruiksaanwijzing Safety Regulations Conseils préliminaires • Das Gerät darf nur von einer Elektrofachkraft oder unterwiesenen Personen


    Original
    PDF

    PNOZ s4

    Abstract: PNOZ s4 C Pilz pnoz s4 PILZ pnoz 751104 Pilz Pnoz 751 104 Pilz pnoz S4 B10d Pilz Pnoz 750 104 Pilz PSEN S3 Pilz safety relay pnoz s4 pnozs4
    Text: E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ s4 Unit features Unit description ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` 1 semiconductor output ` Connection options for:


    Original
    PDF 1001742-EN-03-2010-11 PNOZ s4 PNOZ s4 C Pilz pnoz s4 PILZ pnoz 751104 Pilz Pnoz 751 104 Pilz pnoz S4 B10d Pilz Pnoz 750 104 Pilz PSEN S3 Pilz safety relay pnoz s4 pnozs4

    telemecanique XCS-E

    Abstract: Telemecanique XPS Preventa xps-ac XPSAT5110 XPSAF5130 xpsav11113 XPS-AT3410 telemecanique xps-ak XPS-AC XPSAC5121P
    Text: Machine Safeguarding Products PREVENTA XPS Safety Relays Supplement Catalog 03 File 9007 CONTENTS Description Page Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 General Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12


    Original
    PDF 1-888-SquareD 9007CT0203 telemecanique XCS-E Telemecanique XPS Preventa xps-ac XPSAT5110 XPSAF5130 xpsav11113 XPS-AT3410 telemecanique xps-ak XPS-AC XPSAC5121P

    PNOZ s6

    Abstract: PILZ PNOZ S6 PNOZ s6 AC PILZ pnoz s6.1 Pilz pnozsigma DC-13 S11-S12 pnoz 8 pilz pnoz 1 24v outputY32
    Text: Two-hand relays Up to PL e of EN ISO 13849-1 PNOZ s6 Unit features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` 1 semiconductor output ` Connection options for: – 2 operator elements (buttons)


    Original
    PDF NSG-D-2-397-2010-08 PNOZ s6 PILZ PNOZ S6 PNOZ s6 AC PILZ pnoz s6.1 Pilz pnozsigma DC-13 S11-S12 pnoz 8 pilz pnoz 1 24v outputY32

    ossd output

    Abstract: 24v 8 channel Relay driving 24V ac relays S2NG021 DSAE00636 24v relays s34 diode S34-S35 S11-S12 S1232
    Text: S2NG021 Safety relays - S2 series Base device for Emergency Stop and Safety Gate applications Two-channel activation including Cross Monitoring and Synchronous Time Check Automatic or Manual Star Activation via semiconductor output OSSD possible 2 enabling current paths


    Original
    PDF S2NG021 S12-S35) S11/S33 ossd output 24v 8 channel Relay driving 24V ac relays S2NG021 DSAE00636 24v relays s34 diode S34-S35 S11-S12 S1232

    xps-dme

    Abstract: schema led table data book electronique preventa xps-dme relais demarrage relais schema de branchement magnetic Switch wiring diagrams schema XPS AC schema 100 led sicherheits
    Text: Farnell Code : 4276000 XPS-DME FR GB DE 0RGXOH GH VpFXULWp SRXU DX WRWDO  LQWHUUXSWHXUV PDJQpWLTXHV FRPSRUWDQW FKDFXQ XQ FRQWDFW j IHUPHWXUH HW XQ FRQWDFW j RXYHUWXUH YQT9H@Q 6DIHW\ PRGXOH IRU D WRWDO RI  PDJQHWLF VZLWFKHV ZLWK D QRUPDOO\ RSHQ DQG D QRUPDOO\ FORVHG FRQWDFW HDFK


    Original
    PDF S11-S12, S11-S13) xps-dme schema led table data book electronique preventa xps-dme relais demarrage relais schema de branchement magnetic Switch wiring diagrams schema XPS AC schema 100 led sicherheits

    MSR138DP

    Abstract: GuardMaster trojan 5 6 belden 8770 20-HIM minotaur MSR9T GuardMaster trojan 5 20D-UM006 MSR138 GuardMaster MSR9T
    Text: Safe-Off Option for PowerFlex 700S Phase II AC Drives and PowerFlex 700L Liquid-Cooled AC Drives User Manual www.abpowerflex.com Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and


    Original
    PDF 20D-UM007D-EN-P 363068-P03 20D-UM007C-EN-P 2006Copyright MSR138DP GuardMaster trojan 5 6 belden 8770 20-HIM minotaur MSR9T GuardMaster trojan 5 20D-UM006 MSR138 GuardMaster MSR9T

    PNOZ X2.7P

    Abstract: PILZ pnoz x2.7p pnoz X2 PILZ pnoz s11 pilz p2 S12-S34 pilz pnoz 1 24v Pilz safety relay PILZ pnoz 10 pnoz 777305
    Text: E-STOP relay, safety gate monitor Up to PL e of EN ISO 13849-1 PNOZ X2.7P Unit features Safety features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` Connection options for: – E-STOP pushbutton


    Original
    PDF NSG-D-2-331-2010-08 PNOZ X2.7P PILZ pnoz x2.7p pnoz X2 PILZ pnoz s11 pilz p2 S12-S34 pilz pnoz 1 24v Pilz safety relay PILZ pnoz 10 pnoz 777305

    Pilz safety relay

    Abstract: Pilz PNOZ/X2 PNOZ x2 Pilz PILZ pnoz 10 S11-S12 pnoz 2 NSG-D-2-348-2010-08 IEC 60947-5-1 limit switch KM A1
    Text: E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X2.2 Unit features ` Positive-guided relay outputs: – 2 safety contacts N/O , instantaneous ` Connection options for: – E-STOP pushbutton – Safety gate limit switch – Reset button


    Original
    PDF NSG-D-2-348-2010-08 Pilz safety relay Pilz PNOZ/X2 PNOZ x2 Pilz PILZ pnoz 10 S11-S12 pnoz 2 NSG-D-2-348-2010-08 IEC 60947-5-1 limit switch KM A1

    PNOZ 2VQ

    Abstract: 774013 Pilz safety relay PILZ pnoz 15 S21-S52 S11-S12 pnoz DC124 pnoz 6 pnoz v
    Text: E-STOP relays, safety gate monitors Category 4, EN 954-1 PNOZ 2VQ Unit features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 2 safety contacts (N/O), delay-on de-energisation – 1 auxiliary contact (N/C), instantaneous ` Connection options for:


    Original
    PDF NSG-D-2-063-2010-06 PNOZ 2VQ 774013 Pilz safety relay PILZ pnoz 15 S21-S52 S11-S12 pnoz DC124 pnoz 6 pnoz v

    PILZ pnoz x3

    Abstract: PILZ PNOZ X3 safety relay pnoz x3 Pilz safety relay pnoz x4 PILZ pnoz x4 PILZ PNOZ X3.10P Pilz safety relay x3 IEC 60947-5-1 limit switch KM A1 Pilz safety relay pnoz x3 s PILZ pnoz s11
    Text: E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X3.10P Unit features Safety features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` 1 semiconductor output ` Connection options for:


    Original
    PDF NSG-D-2-322-2010-01 PILZ pnoz x3 PILZ PNOZ X3 safety relay pnoz x3 Pilz safety relay pnoz x4 PILZ pnoz x4 PILZ PNOZ X3.10P Pilz safety relay x3 IEC 60947-5-1 limit switch KM A1 Pilz safety relay pnoz x3 s PILZ pnoz s11

    KS0090

    Abstract: SEG60
    Text: 26COM / 64SEG DRIVER & CONTROLLER FOR DOT MATRIX LCD KS0090 INTRODUCTION The KS0090 is an LCD driver and controller LSI for liquid crystal dot matrix character display systems. It can display 2 or 3 lines of 12 characters with the 5 x 8 dots format. It is capable of interfacing with various


    Original
    PDF 26COM 64SEG KS0090 KS0090 SEG60

    xps-ak

    Abstract: schema XPS Ar xpsAK schema led table xps-ak xps ak schema XPS AC K4 24V xps ak safety relay schema led table schema XPS
    Text: XPS-AK Module de surveillance pour circuits d'ARRET D'URGENCE et de sécurité selon EN 418 / EN 60204-1 Safety relay for monitoring EMERGENCY STOP and safety circuits according to EN 418 / EN 60204-1 XPS-AK.P Überwachungsbaustein für NOT-AUS und Sicherheitskreise


    Original
    PDF

    XPS-AT

    Abstract: variateur de vitesse timer relais schema B1S12 APPLICATION for MIN 5758 B1-S12 schema led table EN418 VARIATEUR DE FREQUENCE XPSAt
    Text: XPS-AT FR GB Application DE Module de surveillance pour circuits d'ARRET D'URGENCE selon EN 418 / EN 60204-1: 1992 Safety relay for monitoring EMERGENCY STOP circuits according to EN 418 / EN 60204-1: 1992 Überwachungsbaustein für NOT AUS Kreise gemäß EN 418 / EN 60204-1: 1992


    Original
    PDF

    S33-S34

    Abstract: S11-S12 DIN 50016 S33-S35 DC-13 debouncing relay contact normally closed normally open operation of relay insulation monitoring device S11S12
    Text: S2NGR120 Safety relays - S2 series Base device with settable delay time for Emergency Stop and Safety Gate applications Two-channel activation with Cross Monitoring and Synchronous Time Check Automatic or Manual Star 2 non-delayed enabling current paths stop category 0


    Original
    PDF S2NGR120 S11/S12) S21-S22) S33-S35) S33-S34 S11-S12 DIN 50016 S33-S35 DC-13 debouncing relay contact normally closed normally open operation of relay insulation monitoring device S11S12

    pnoz X2.8P

    Abstract: pilz 777301 777302 S12-S34 PILZ pnoz s11 PILZ pnoz x2.8P S11-S12 pnoz v Pilz Pnoz S3 RELAY 8P
    Text: E-STOP relays, safety gate monitors Up to Category 4, EN 954-1 PNOZ X2.8P Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals PNOZ X2.8P Unit features ` Light barriers ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous


    Original
    PDF NSG-D-2-332-2006-12 pnoz X2.8P pilz 777301 777302 S12-S34 PILZ pnoz s11 PILZ pnoz x2.8P S11-S12 pnoz v Pilz Pnoz S3 RELAY 8P

    XPS-ASf

    Abstract: XPS-ASF5142 XPS-AS XPS-ASF3442 XPS-Apf xpsasf5142 XPS-ASF3742 Y33-Y34 xps-bc S41-S42
    Text: Components for safety applications Preventa safety modules for emergency stop, limit switch, two-hand control, safety mat and edge monitoring Operating principle, characteristics Operating principle see page 1/12 1 Characteristics Type XPS-ASF Product designed for use in safety


    Original
    PDF S11-S12, S21-S22 S11-B1 S21-S22 S11-S12) S33-S34 S21-S22) Y33/43 XPS-ASf XPS-ASF5142 XPS-AS XPS-ASF3442 XPS-Apf xpsasf5142 XPS-ASF3742 Y33-Y34 xps-bc S41-S42

    Pilz safety relay

    Abstract: pnoz 11 PILZ pnoz PILZ pnoz 11 relay 1210 S33S3 S11-S12 two-hand PILZ PNOZ S11 Safety relay PILZ
    Text: E-STOP relay, safety gate monitor Up to Category 4, EN 954-1 PNOZ 11 Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals PNOZ 11 Unit features Safety features ` Positive-guided relay outputs: – 7 safety contacts N/O , instantaneous


    Original
    PDF NSG-D-2-058-12/04 Pilz safety relay pnoz 11 PILZ pnoz PILZ pnoz 11 relay 1210 S33S3 S11-S12 two-hand PILZ PNOZ S11 Safety relay PILZ