Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DIN46199 Search Results

    DIN46199 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    MK3P-i

    Abstract: PF113A-D DIN46199 PF083A-D MK3P A1274 norme UL csa PF-113A-D MK2P-I application MK3P I
    Text: SOCLE POUR RELAIS UNIVERSEL Isolation conforme à la norme VDE 0110 groupe C250 et conforme aux normes VDE, SEV, UL et CSA. Section et capacité de fixation importantes pour les connexions. Marquage conforme aux normes DIN46199 et IEC 667. 10 A, 380 Vc.a.


    Original
    PDF DIN46199 PF083A-D PF113A-D PF083A-D PF113A-D MK3P-i MK3P A1274 norme UL csa PF-113A-D MK2P-I application MK3P I

    MCU10

    Abstract: mxp a 100 relay MXP C 100 40 05 DIN46199 MXV-10 MCU-10 MXP A 100 40 05 MXP A 100 49 10 MXV-20
    Text: Control & Monitoring Relays Phase Monitoring Relay MXP-20 OPERATION A relay for monitoring a 3-phase AC power supply with or without Neutral. The relay monitors that all phases are available and in the correct phase sequence L1, L2, L3 U,V,W , that none of the phases


    Original
    PDF MXP-20 MCU-10 MCP-10 VDE0609-1) DIN46199/EN50005. 75kVAC EN60950) UL94V1. UL94V0. MCU10 mxp a 100 relay MXP C 100 40 05 DIN46199 MXV-10 MCU-10 MXP A 100 40 05 MXP A 100 49 10 MXV-20

    PXL-10

    Abstract: relay 5v 100 ohm Input 24V Output 5V 2W DC DC 50-270W 5v 24v relay EN60204-1 24v dc 240v ac inverter IEC68-2-3 relay 230V DC 4276v
    Text: Signal Converters & Isolators Threshold Relay PXL-10 DESCRIPTION OPERATION A threshold relay for the monitoring or control of common types of process signals. The process signal to be monitored is selected on the front panel and the threshold value is also adjusted via a setpoint


    Original
    PDF PXL-10 PXT-10/11 PXF-10 0-20mA 4-20mA PXF-20 PXL-10 relay 5v 100 ohm Input 24V Output 5V 2W DC DC 50-270W 5v 24v relay EN60204-1 24v dc 240v ac inverter IEC68-2-3 relay 230V DC 4276v

    Thermistor kty

    Abstract: Thermistor, kty 0-500V AC voltmeter diagram free AAS-100 phase failure relay 12v dc 240v ac inverter circuit diagram MXV-10 0-500V AC voltmeter wiring diagram inverter DC 12v to AC 220v MCU10
    Text: MCP-10 INTRO. Control & Monitoring Relays Introduction & Selection Guide INTRODUCTION MCU-10 Digital control relay MCP-10 Phase monitoring relay MCU-10 DC/AC MCU-10 DV/AV The Brodersen monitoring relays are high quality products incorporating up-to-date circuit design


    Original
    PDF MCP-10 MCU-10 MCP-10 MXC-10 DIN46199/EN50005. 75kVAC EN60950) Thermistor kty Thermistor, kty 0-500V AC voltmeter diagram free AAS-100 phase failure relay 12v dc 240v ac inverter circuit diagram MXV-10 0-500V AC voltmeter wiring diagram inverter DC 12v to AC 220v MCU10

    MXP A 100 49 10

    Abstract: DIN43760 mxp a 100 relay MXT-10 pt100 0-10V
    Text: Control & Monitoring Relays Thermostat Relay MXT-10 DESCRIPTION OPERATION A thermostat relay for the monitoring or control of temperature in the range -50 to 300°C. The probe is a standard Pt100, either 2 or 3 wire. LED indication of a non-functional probe and relay activated.


    Original
    PDF MXT-10 Pt100, 0-10VDC A/24V MXP-10 MXP-20 MXL-10 Pt100 Pt-100 MXV-10 MXP A 100 49 10 DIN43760 mxp a 100 relay MXT-10 pt100 0-10V

    MXP A 100 49 10

    Abstract: control relay a1 a2 mxl10
    Text: Control & Monitoring Relays Level Relay MXL-10 DESCRIPTION OPERATION A level control relay for most conductive fluids. With a 2 or 3 wire probe, one or two levels in a container can be controlled. Signal at maximum with jumper . The probe is a conducting rod, the length of which can be adjusted


    Original
    PDF MXL-10 220kOhm. MXV-20 MCP-10 MXP-10 MXP-20 MXT-10 MXP A 100 49 10 control relay a1 a2 mxl10

    omron PF113A-D

    Abstract: MK3P-i omron MK3P-I RELAY MK3P-I PF113A-D OMRON PF083A-D PF083A-D DIN46199
    Text: Track Mounted Socket PF-D Insulation According to VDE 0110 group C and Safety Distance According to VDE, SEV, and CSA. Large section and clamping capacity for connections: 2 x 1.5 mm2 with terminal and 2 x 2.5 mm2 without terminal. Double nomenclature of connecting terminals


    Original
    PDF DIN46199 PF083A-D PF113A-D omron PF113A-D MK3P-i omron MK3P-I RELAY MK3P-I PF113A-D OMRON PF083A-D PF083A-D

    EN50005

    Abstract: 5V SPDT relay relay 24v 50mA SPDT relay 5v pdf datasheet relay 5v 100 ohm for ac 24V to 0-10v POTENTIOMETER relay 5v 100 ohm SPDT Relay 5V 24V to 0-10v 0-10V to 0-20mA converter
    Text: Signal Converters & Isolators Threshold Relay PXL-10 DESCRIPTION OPERATION A threshold relay for the monitoring or control of common types of process signals. The process signal to be monitored is selected on the front panel and the threshold value is also adjusted via a setpoint


    Original
    PDF PXL-10 IEC68-2-3; IEC68-2-6: IEC68-2-27. PXF-20 PXC-10 A/240V capacity2000VA. A/24V 0-270W. EN50005 5V SPDT relay relay 24v 50mA SPDT relay 5v pdf datasheet relay 5v 100 ohm for ac 24V to 0-10v POTENTIOMETER relay 5v 100 ohm SPDT Relay 5V 24V to 0-10v 0-10V to 0-20mA converter

    5v 24v relay

    Abstract: relay 5v 100 ohm for ac OF RELAY -5V, 230V INPUT relay 24v 50mA PXT-200 4-20ma ssr PXT-100 Signal Converters EN50005 latching relay GE
    Text: Signal Converters & Isolators Threshold Relay PXL-20 DESCRIPTION OPERATION A threshold relay for the monitoring or control of common types of process signals. The process signal to be monitored is selected on the front panel and the threshold value is also adjusted via a setpoint


    Original
    PDF PXL-20 PXF-20 PXL-10 50Vp-p PXT-10/11 100kOhm PXT-100 5v 24v relay relay 5v 100 ohm for ac OF RELAY -5V, 230V INPUT relay 24v 50mA PXT-200 4-20ma ssr PXT-100 Signal Converters EN50005 latching relay GE

    MXP C 100 40 05

    Abstract: MXP A 100 49 10 MXP A 100 55 10 MXP A 100 40 05 MXP A 100 55 05 230v 3 phase relay MXP A 100 44 05 VDE0609-1 8A240VAC MCU10
    Text: Control & Monitoring Relays 3-Phase Monitoring Relay MXP-10 DESCRIPTION OPERATION A relay for monitoring a 3-phase AC power supply with or without Neutral. The relay monitors that all phases are available and in the correct phase sequence U,V,W , that none of the phases are


    Original
    PDF MXP-10 115/3x230/3x400VAC) MXV-30 75kVAC EN60950) UL94V1. UL94V0. MXT-10 MXL-10 MXP C 100 40 05 MXP A 100 49 10 MXP A 100 55 10 MXP A 100 40 05 MXP A 100 55 05 230v 3 phase relay MXP A 100 44 05 VDE0609-1 8A240VAC MCU10