DVP04DA-S
Abstract: DVP-04DA delta plc dvp ex delta plc RS-485 PLC delta rtu application DVP04DAS 403B DC24V K128 8H8R
Text: CR External Wiring # DVP04DA-S voltage output 0V~+10V *2 AC drive, recorder, scale valve. CH1 shielding cable *1 current output AC drive, recorder, scale valve. CH4 shielding cable *1 terminal of power module V+ I+ COM FG CH1 V+ I+ COM FG CH4 DC/DC 24+
|
Original
|
RS-485
DVP04DA-S
DVP-04DA
delta plc dvp ex
delta plc RS-485
PLC delta rtu application
DVP04DAS
403B
DC24V
K128
8H8R
|
PDF
|
DVP04DA-H2
Abstract: h4052 h4053 1B457 H2B2 MM 4054 H4033 DVP04DA-H h4032 delta plc RS-485
Text: External Wiring *2 voltage output 0V~+10V AC drive, recorder, scale valve. CH1 shielding cable *1 RS-485 CR parameter Latched # address V+ I+ COM FG CH1 V+ I+ COM FG CH4 #27 CH4 AC drive, recorder, scale valve. shielding cable *1 ○ R/W Adjusted GAIN value of CH4
|
Original
|
DC24V
RS-485
000LSB
DVP04DA-H2
h4052
h4053
1B457
H2B2
MM 4054
H4033
DVP04DA-H
h4032
delta plc RS-485
|
PDF
|
DVP04DA-H
Abstract: delta plc DVP-EH PT100 T H4063 M1002 H4054 403B 404B 404D
Text: 1. DIN rail track 35mm 2. Mounting hole for wire to connect extension unit/extension module 3. Model name http://www.delta.com.tw/products/plc.asp DVP04DA-H Analog Input Module DVP-EH 4. Indicator for power, error and run status WARNING Please carefully read this instruction thoroughly prior to use the DVP04DA-H.
|
Original
|
DVP04DA-H
DVP04DA-H.
DC24V
03H--read
06H--write
10H--write
M1083
M1080
DVP04DA-H
delta plc
DVP-EH
PT100 T
H4063
M1002
H4054
403B
404B
404D
|
PDF
|
DVP06XA-S
Abstract: DVP-06XA DVP-04DA DVP04DA-S DVP04AD-S DVP04PT-S DVP04TC-S DVP04DA PT100 T DVP06
Text: 1. Status indicator Power, RUN and ERROR 2. Model name 3. DIN rail clip 4. I/O terminals 5. I/O point indicator 6. Mounting hole of the expansion unit 7. Nameplate http://www.delta.com.tw/products/plc.asp DVP04DA-S DVP04DA-S 2.3 Analog Output Module 1 voltage output
|
Original
|
DVP04DA-S
DVP04DA-S,
DVP04DA-S
M1083
M1083
M1080
DVP06XA-S
DVP-06XA
DVP-04DA
DVP04AD-S
DVP04PT-S
DVP04TC-S
DVP04DA
PT100 T
DVP06
|
PDF
|
K4096
Abstract: DVP-06XA DVP06XA-H K2600 K4096 DATASHEET sensor 40DD delta DVP H0604 DVP06X K1600
Text: 1. DIN rail track 35mm 2. Mounting hole for wire to connect extension unit/extension module 3. Model name http://www.delta.com.tw/products/plc.asp DVP-EH DVP06XA-H Analog Input/Output Mixed Module 4. Indicator for power, error and run status 2.3 *3 V+ I+
|
Original
|
DVP06XA-H
DVP06XA-H
K1000LSB)
H0604
DVP06XA-H,
K4000.
K4096
DVP-06XA
K2600
K4096 DATASHEET
sensor 40DD
delta DVP
DVP06X
K1600
|
PDF
|
DVP-06XA
Abstract: DVP06XA-S DVP06XA-S instruction DVP 28 sv 40C8 DVP06 DC24V DVP 28 sv plc b6010 DVP-02
Text: *5 voltage output 0V~+10V AC drive, recorder, scale valve. CH5 shielding cable *1 current output 0mA~20mA AC drive, recorder, scale valve. V+ I+ COM DVP06XA-S CH5 V+ I+ COM V+ I+ COM V+ I+ COM V+ I+ COM V+ I+ COM V+ I+ COM CH6 V+ I+ COM CH6 shielding cable *4
|
Original
|
16-bit,
DVP06XA-S
000LSB
400LSB)
800LSB)
000LSB)
400LSB
DVP-06XA
DVP06XA-S instruction
DVP 28 sv
40C8
DVP06
DC24V
DVP 28 sv plc
b6010
DVP-02
|
PDF
|
DVP-06XA
Abstract: 40C8 DVP06 B2CH5 K128 dvp06xa-h2 DVP06X ch6d 40DF
Text: *5 Vo lt ag e o utpu t 0V ~+10V CH 5 AC m o tor drive Sh iel din g R e cor der ca ble *1 Sc ale val ve . C urren t output 0m A~20 m A AC m o tor drive R e cor der Sc ale val ve . Term inal of p ow er m od ule C H6 C H5 V+ I+ C OM C H6 Shi eld i ng ca ble *4
|
Original
|
000LSB.
000LSB
400LSB
800LSB)
400LSB)
DVP-06XA
40C8
DVP06
B2CH5
K128
dvp06xa-h2
DVP06X
ch6d
40DF
|
PDF
|
K25 4032
Abstract: DVP-04DA CR-31 4032 k25 M1002 DVP-04DA-h2 diode 4052 k1 403B 404C 404D
Text: 2007-01-15 Control Registers 1.3 External Wiring DVP04DA-H2 analog output module 5011651101-D2E1 http://www.delta.com.tw/industrialautomation/ *2 Analog Output Module AC drive, recorder, scale valve. CR# parameter Latched Register content CH1 shielding cable *1
|
Original
|
DVP04DA-H2
5011651101-D2E1
000LSB)
K25 4032
DVP-04DA
CR-31
4032 k25
M1002
DVP-04DA-h2
diode 4052 k1
403B
404C
404D
|
PDF
|
DVP-04AD
Abstract: DVP02AD-S DVP02DA-S DVP-02AD DVP-02DA-S h4052 H40520 DVP 28 sv plc delta plc dvp ex H403D
Text: RS-485 CR parameters Latched # address External Wiring Voltage output 0V ~ 10V *2 DVP02DA-S Isolation wire Current output 0mA~20mA AC drive, recorder, scale valve. Isolation wire CH1 V+ I+ COM FG V+ I+ COM FG I+ *1 COM FG I+ COM *1 Power source abnormal
|
Original
|
RS-485
16-bit,
RS-485
RS-485)
000LSB
400LSB
DVP-04AD
DVP02AD-S
DVP02DA-S
DVP-02AD
DVP-02DA-S
h4052
H40520
DVP 28 sv plc
delta plc dvp ex
H403D
|
PDF
|
DVP06XA-S
Abstract: DVP-06XA DVP06XA-S instruction DVP-06XA-S K4096 DVP06XAS DVP 06 xa plc K4096 DATASHEET DVP06X DVP02DA-S
Text: http://www.delta.com.tw/products/plc.asp DVP06XA-S 1. Status indicator Power, RUN and ERROR 2. Model 3. DIN rail clip 4. I/O terminals 5. I/O terminals layout 6. Expansion hole of the expansion unit 7. Specification Label 2.3 1 CH1 *3 2 2.1 Current input
|
Original
|
DVP06XA-S
-20mA~
DVP06XA-S
DVP06XA-S,
K4000,
DVP-06XA
DVP06XA-S instruction
DVP-06XA-S
K4096
DVP06XAS
DVP 06 xa plc
K4096 DATASHEET
DVP06X
DVP02DA-S
|
PDF
|
dvp06xa-h2
Abstract: DVP 06 xa plc D100D H6604 40C8 DC24V IEC1131-2 M1013 K800
Text: 2007-01-10 1.3 External Wiring 2.2. Voltage input -10V ~ +10V CH1 *3 5011652400-X2E0 http://www.delta.com.tw/industrialautomation/ 100K V+ I+ COM 100K Shielding cable *1 Current input -20mA ~ +20mA Mixed Analog Input/Output Module 9 CH4 Voltage output 0V~+10V
|
Original
|
5011652400-X2E0
-20mA
DVP06XA-H2
DVP 06 xa plc
D100D
H6604
40C8
DC24V
IEC1131-2
M1013
K800
|
PDF
|
DVP-04Ad
Abstract: DVP04AD-S DVP02DA-S DVP04DA-S DVP-06XA h4062 DVP EH series PLC DVP-02 DVP04PT-S DVP08RT-S
Text: 1. Status indicator Power, RUN and ERROR 2. Model name 3. DIN rail clip 4. I/O terminals 5. I/O point indicator 6. Mounting hole of the expansion unit 7. Nameplate http://www.delta.com.tw/products/plc.asp DVP02DA-S DVP02DA-S Analog Output Module 2.3 WARNING
|
Original
|
DVP02DA-S
DVP02DA-S
DC24V
M1083
M1083
M1080
DVP-04Ad
DVP04AD-S
DVP04DA-S
DVP-06XA
h4062
DVP EH series PLC
DVP-02
DVP04PT-S
DVP08RT-S
|
PDF
|
2S50
Abstract: No abstract text available
Text: ANALOG DEVICES LVDT-to-Digital Converter 2S50 FEATURES Internal Signal Conditioning Direct Conversion to Digits Reference Frequency 400Hz or 1kHz to 10kHz High MTBF No External Trims Absolute Encoding F U N CTIO N A L BLOCK DIAGRAM APPLICATIONS Industrial Measurement and Gauging
|
OCR Scan
|
400Hz
10kHz
2S50
|
PDF
|
2S50-560
Abstract: DH32E 2S50
Text: ANALOG DEVICES LVDT-to-Digital Converter 2S50 FEATURES Internal Signal Conditioning Direct Conversion to Digits Reference Frequency 400Hz or 1kHz to 10kHz High MTBF No External Trims Absolute Encoding FUN CTIO N A L BLOCK DIAGRAM APPLICATIONS Industrial Measurement and Gauging
|
OCR Scan
|
400Hz
10kHz
--17V
2S50-560
DH32E
2S50
|
PDF
|
|