Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    4 WIRE RTD CABLE Search Results

    4 WIRE RTD CABLE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MP-5XRJ11PPXS-014 Amphenol Cables on Demand Amphenol MP-5XRJ11PPXS-014 Flat Silver Satin Modular Crossed wiring Cable, RJ11 / RJ11 14ft Datasheet
    SF-NDCCGJ28GB-003M Amphenol Cables on Demand Amphenol SF-NDCCGJ28GB-003M 3m SFP28 Cable - Amphenol 25-Gigabit Ethernet SFP28 Direct Attach Copper Cable (9.8 ft) - 26 AWG (Low-Loss Version) Datasheet
    SF-NDCCGJ28GB-002M Amphenol Cables on Demand Amphenol SF-NDCCGJ28GB-002M 2m SFP28 Cable - Amphenol 25-Gigabit Ethernet SFP28 Direct Attach Copper Cable (6.6 ft) - 26 AWG (Low-Loss Version) Datasheet
    SF-NDCCGJ28GB-005M Amphenol Cables on Demand Amphenol SF-NDCCGJ28GB-005M 5m SFP28 Cable - Amphenol 25-Gigabit Ethernet SFP28 Direct Attach Copper Cable (16.4 ft) - 26 AWG Datasheet
    SF-NDAAFJ100G-002M Amphenol Cables on Demand Amphenol SF-NDAAFJ100G-002M 2m (6.6') 100GbE QSFP28 Cable - Amphenol 100-Gigabit Ethernet Passive Copper QSFP Cable (SFF-8665 802.3bj) - QSFP28 to QSFP28 (26-AWG Low-Loss) Datasheet

    4 WIRE RTD CABLE Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: OMB-DBK9 8-Channel RTD Measurement Card for OMB-LOGBOOK, OMB-DAQBOOK and DAQBOARD Model OMB-DBK9 MADE IN 495 $ USA The 8-channel OMB-DBK9 RTD card accommodates three- and four-wire RTD’s ߜ Provides 8 RTD Channels ߜ Supports 3- and 4-Wire RTD’s ߜ Supports Three Ranges


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Transmitters: TT230 Series TT231 RTD/resistance input two-wire/three-wire transmitter BOTTOM VIEW INPUT SIDE TOP VIEW (OUTPUT SIDE) 1 2 5 6 Platinum RTD or Resistance Input Local Power Supply w/ Sourced Output H 2 4-WIRE 3-WIRE 2-WIRE 5 – 1 IN+ 3 4 7 8


    Original
    PDF TT230 TT231 24VDC 4-20mA TT231-0600

    Untitled

    Abstract: No abstract text available
    Text: Transmitters: ST130 Series ST131 RTD input head-mount transmitter INPUT CONNECTIONS USB Configured DIMENSIONS Dimensions in millimeters inches INPUT TERMINALS PT RTD OR RESISTANCE 4-WIRE 3-WIRE 2-WIRE IN – 3 4 Ø T2 2 + IN 1 USB 33.00 (1.299) – 3 T3


    Original
    PDF ST130 ST131 4-20mA ST130-DIN 4001-115K 4001-116K

    Untitled

    Abstract: No abstract text available
    Text: Transmitters: TT330 Series TT335 Isolated RTD/resistance input four-wire transmitter BOTTOM VIEW INPUT SIDE TOP VIEW (OUTPUT & POWER SIDE) RTD Sensor or Resistance Input 3-WIRE 4-WIRE 1 1 4 4 4 1 2 3 7 8 TB1 9 OUTPUT 9 + – 8 TB3 7 – 4 2 2 2 5 CURRENT


    Original
    PDF TT330 TT335 2-32V TT300

    Untitled

    Abstract: No abstract text available
    Text: Transmitters: TT230 Series TT235 Isolated RTD/resistance input two-wire transmitter BOTTOM VIEW INPUT SIDE TOP VIEW (OUTPUT SIDE) 1 2 5 6 RTD Sensor or Resistance Input 3-WIRE 4-WIRE 2-WIRE 1 1 1 3 3 3 Local Power Supply w/ Sourced Output + 6 5 – 3 4 7 8


    Original
    PDF TT230 TT235 24VDC 4-20mA

    of 3 pin rtd sensor

    Abstract: PCI-1200 SC-2042-RTD of rtd sensor ACH15 DAQCard-1200 AT-MIO-16H PR50-50F SINGLE Current Sensing Channel BOARD 3 wire RTD sensor
    Text: 8-Channel RTD Signal Conditioning Accessory SC-2042-RTD SC-2042-RTD Features 8 inputs for mixed signal types RTDs – 4, 3, or 2-wire differential Thermistors (to 8.5 kΩ) Millivolt and volt sources 8 independent current excitation sources Direct connection to DAQ products


    Original
    PDF SC-2042-RTD Lab-PC-1200, Lab-PC-1200AI PCI-1200 DAQCard-1200 DAQPad-1200 SC-2042-RTD of 3 pin rtd sensor PCI-1200 of rtd sensor ACH15 DAQCard-1200 AT-MIO-16H PR50-50F SINGLE Current Sensing Channel BOARD 3 wire RTD sensor

    Untitled

    Abstract: No abstract text available
    Text: RN-ISENSOR-CB www.rovingnetworks.com rn-isensor-cb-ds v0.1 11/20/2010 “Cool box” WiFi temperature sensor Features • ABS plastic enclosure 4" x 2.5" X 3/4"  Auto Sensing Analog port: External 100 ohms RTD temperature probe with 2 wire, 3 wire and 4 wire configuration capable of


    Original
    PDF 4-20ma 150mA

    SCXI-1102

    Abstract: transistor 1102 SCXI-1581 Logger
    Text: SCXI 32-Channel RTD Measurement Solution NI SCXI-1102 and SCXI-1581 • 32 channels of RTD 3 or 4-wire or thermistor inputs • 2 Hz lowpass filter per channel • 333 kS/s maximum sampling rate • 100 µA current excitation • ±0.05% accuracy per channel


    Original
    PDF 32-Channel SCXI-1102 SCXI-1581 2000/NT/XP SCXI-1581 SCXI-1102, transistor 1102 Logger

    PT-100 RTD 3 wire transmitter

    Abstract: pt 100 temperature sensor RTD abb PT-100 ABB PT-100 RTD 3 wire PT-100 RTD 3 wire sensor rosemount Pt 100 sensor connection Pt 100 sensor connection 3-WIRE RTD PT-100 pt 100 temperature sensor abb SIMULATOR 4.20 mA
    Text: TS 04 Head-mounted temperature transmitter, programmable via push-button, Pt 100 2/3-wire RTD 10/11-8.16 EN • Input – Pt 100 resistance thermometer (2-wire or 3-wire) ■ Output – 2-wire technique – 4.20 mA – Temperature-linear ■ Deviation 0.15 %


    Original
    PDF V11506-1300 PT-100 RTD 3 wire transmitter pt 100 temperature sensor RTD abb PT-100 ABB PT-100 RTD 3 wire PT-100 RTD 3 wire sensor rosemount Pt 100 sensor connection Pt 100 sensor connection 3-WIRE RTD PT-100 pt 100 temperature sensor abb SIMULATOR 4.20 mA

    sensycon tr 11-l

    Abstract: PT-100 sensycon EC certificate PTB ATEX 1144 X sensycon ABB sensycon RTD sensycon abb sensycon pt 100 PTB 99 ATEX 1144 X AGLF sensycon ts
    Text: TR 204 / TR 204-Ex Field mounted Temperature transmitters, analog, Pt 100 RTD , fixed measuring ranges 10/11-8.59 EN • Input – Resistance thermometer (2- and 3-wire circuit) – optionally 4-wire circuit ■ Output – 2-wire methode – 4.20 mA ■ Digital, low drift processing of measuring values


    Original
    PDF 204-Ex Z-20161 D-63755 sensycon tr 11-l PT-100 sensycon EC certificate PTB ATEX 1144 X sensycon ABB sensycon RTD sensycon abb sensycon pt 100 PTB 99 ATEX 1144 X AGLF sensycon ts

    TR04-Ex

    Abstract: TR04-ECO V11531-30 Pt 100 sensor connection 2.4 ghz FM TRANSMITTER CIRCUIT DIAGRAM terminal EEx e II T6 D-63755 Pt 100 sensor connection 3-WIRE PT-100 RTD 3 wire sensor rosemount buzh
    Text: TR 04-Eco / TR 04-Ex Head mounted Temperature transmitters, analog, Pt 100 RTD , fixed measuring ranges 10/11-8.14 EN • Input – Resistance thermometer (2- and 3-wire circuit) – optionally 4-wire circuit ■ Output – 2-wire methode – 4.20 mA ■ Digital, low drift processing of measuring values


    Original
    PDF 04-Eco 04-Ex 04-Eco/-Ex Z-187631 Z-20047 Z-20017 D-63755 TR04-Ex TR04-ECO V11531-30 Pt 100 sensor connection 2.4 ghz FM TRANSMITTER CIRCUIT DIAGRAM terminal EEx e II T6 Pt 100 sensor connection 3-WIRE PT-100 RTD 3 wire sensor rosemount buzh

    buzh

    Abstract: PT-100 RTD 3 wire sensor rosemount TR04-ECO TR04-Ex 2.4 ghz FM TRANSMITTER CIRCUIT DIAGRAM Pt 100 sensor connection PTB 20017 D-63755 PTB 99 ATEX V11531-30
    Text: TR 04-Eco / TR 04-Ex Head mounted Temperature transmitters, analog, Pt 100 RTD , fixed measuring ranges 10/11-8.14 EN • Input – Resistance thermometer (2- and 3-wire circuit) – optionally 4-wire circuit ■ Output – 2-wire methode – 4.20 mA ■ Digital, low drift processing of measuring values


    Original
    PDF 04-Eco 04-Ex 04-Eco/-Ex Z-187631 Z-20047 Z-20017 D-63755 buzh PT-100 RTD 3 wire sensor rosemount TR04-ECO TR04-Ex 2.4 ghz FM TRANSMITTER CIRCUIT DIAGRAM Pt 100 sensor connection PTB 20017 PTB 99 ATEX V11531-30

    th202

    Abstract: ABB Hart Temperature Transmitter TH202 TH202-Ex 3KDE115040R4501 tag 8530 pt 100 temperature sensor RTD abb NGV220-EX agsfd V11523 fuse terminal EEx "e" II - T6
    Text: Data Sheet 10/11-8.64 EN Field mounted Temperature Transmitter TH202/TH202-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    PDF TH202/TH202-Ex th202 ABB Hart Temperature Transmitter TH202 TH202-Ex 3KDE115040R4501 tag 8530 pt 100 temperature sensor RTD abb NGV220-EX agsfd V11523 fuse terminal EEx "e" II - T6

    abb ts202

    Abstract: SENSORS TEMPERATURE Pt-100-DIN 43760 dmt 90 atex g 001 DMT 02 ATEX F 001 atex 2035 EC certificate PTB ATEX 1144 X prometer PTB 01 ATEX 2035 PTB 2035 X pt 100 temperature sensor RTD abb
    Text: FieldIT Data Sheet 10/11-8.62 EN Field mounted Temperature Transmitter TS202/TS202-Ex programmable, Pt 100 RTD , thermocouples, electrical isolation • Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    PDF TS202/TS202-Ex abb ts202 SENSORS TEMPERATURE Pt-100-DIN 43760 dmt 90 atex g 001 DMT 02 ATEX F 001 atex 2035 EC certificate PTB ATEX 1144 X prometer PTB 01 ATEX 2035 PTB 2035 X pt 100 temperature sensor RTD abb

    namur ne43

    Abstract: Ni100 sensor Pt100 transmitter 4.20 mA PR 5131A IEC584 pTC-10 ohm PT100 3 wire connected diagram namur NE 43 pt100 atex NE43
    Text: PRetrans 5131 2-WIRE PROGRAMMABLE TRANSMITTER Input for RTD, TC, mV, linear resistance, mA, and V 3.75 kVAC galvanic isolation 4.20 mA loop output 1- and 2-channel versions ATEX Ex version DIN rail mounting Application: Electronic temperature measurement with resistance


    Original
    PDF 5131B namur ne43 Ni100 sensor Pt100 transmitter 4.20 mA PR 5131A IEC584 pTC-10 ohm PT100 3 wire connected diagram namur NE 43 pt100 atex NE43

    Pt 100 RTD Siemens

    Abstract: Thermocouple Type L siemens 611 thermocouple Pt 200 RTD Siemens RTD MODULE Siemens type k thermocouple input characteristics profile siemens thermocouple TF12-Ex pt 100 temperature sensor RTD abb Pt 1000 sensor siemens
    Text: Data Sheet 10/11 8.26 EN FieldIT Temperature Transmitter, head mounted TF12/TF12-Ex PROFIBUS PA, Pt 100 RTD , Thermocouples, 1 or 2 independent channels • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling units


    Original
    PDF TF12/TF12-Ex Pt 100 RTD Siemens Thermocouple Type L siemens 611 thermocouple Pt 200 RTD Siemens RTD MODULE Siemens type k thermocouple input characteristics profile siemens thermocouple TF12-Ex pt 100 temperature sensor RTD abb Pt 1000 sensor siemens

    SENSORS TEMPERATURE Pt-100-DIN 43760

    Abstract: PTB 01 ATEX 2035 TS102 TS102-EX atex 2123 pt 100 temperature sensor RTD abb Pt 100 sensor connection PT-100 temperature pt 100 temperature sensor abb ptb 99 atex 2123
    Text: FieldIT Data Sheet 10/11-8.50 EN Rail mounted Temperature Transmitter TS102/TS102-Ex programmable, Pt 100 RTD , thermocouples, electrical isolation • Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    PDF TS102/TS102-Ex SENSORS TEMPERATURE Pt-100-DIN 43760 PTB 01 ATEX 2035 TS102 TS102-EX atex 2123 pt 100 temperature sensor RTD abb Pt 100 sensor connection PT-100 temperature pt 100 temperature sensor abb ptb 99 atex 2123

    PT100 3 wire temperature sensor

    Abstract: 1XPt100 PT100 temperature sensor PT100 temperature sensor class B PT100 temperature sensor data sheet PT100 PT100 standard IEC 60751 accuracy
    Text: CombiTemp TFRH TM Hygienic – RTD temperature sensor Main features „„ Pt100 sensor element, 2- or 4-wire „„ Built in graphical display, ­CombiViewTM DFON optional „„ Head mounted 4.20 mA ­transmitter, FlexTop type 22xx „„ HART , PA „„ ATEX


    Original
    PDF Pt100 1xPt100 DN25/DN38 PT100 3 wire temperature sensor PT100 temperature sensor PT100 temperature sensor class B PT100 temperature sensor data sheet PT100 standard IEC 60751 accuracy

    Resistance characteristic Ni1000

    Abstract: ABB Pt100 3 wire accuracy of K type thermocouple EC certificate PTB ATEX 1144 X pt100 atex PT100 IEC 751 PT1000 temperature sensor circuit diagram temperature measurement rtd Ni120 PT-100 RTD 3 wire sensor rosemount
    Text: FieldIT Data Sheet 10/11-8.69 EN Field mounted Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 RTD , thermocouples, 1 or 2 independent channels • Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit


    Original
    PDF TF202/TF202-Ex Resistance characteristic Ni1000 ABB Pt100 3 wire accuracy of K type thermocouple EC certificate PTB ATEX 1144 X pt100 atex PT100 IEC 751 PT1000 temperature sensor circuit diagram temperature measurement rtd Ni120 PT-100 RTD 3 wire sensor rosemount

    pt100 atex

    Abstract: AGLF NGV220-EX ABB Pt100 3 wire agsfd Thermocouple Type K Thermocouple color codes cable Ni100 sensor NGV220-NO Ni120 sensor
    Text: Data Sheet 10/11-8.69 EN Field mounted Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 RTD , thermocouples, 1 or 2 independent channels • Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit


    Original
    PDF TF202/TF202-Ex pt100 atex AGLF NGV220-EX ABB Pt100 3 wire agsfd Thermocouple Type K Thermocouple color codes cable Ni100 sensor NGV220-NO Ni120 sensor

    ABB Pt100 3 wire

    Abstract: pt100 temperature sensor circuit diagram TF02 Ni100 sensor 455 3968 PT100 PT100 temperature sensor ABB PT100 ABB ABB thermocouple pt100 4 wire BUZH, Aluminum
    Text: FieldIT Data Sheet 10/11-8.25 EN Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus H1, Pt 100 RTD , thermocouples, 1 or 2 independent channels • Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit


    Original
    PDF TF02/TF02-Ex ABB Pt100 3 wire pt100 temperature sensor circuit diagram TF02 Ni100 sensor 455 3968 PT100 PT100 temperature sensor ABB PT100 ABB ABB thermocouple pt100 4 wire BUZH, Aluminum

    rosemount 1144

    Abstract: rosemount pt 100 rtd V11523 pt100 rtd rosemount PT100 rosemount EC certificate PTB ATEX 1144 X Thermocouple Type L namur NE 43 rosemount PT 441 rosemount PT-1000 sensor
    Text: FieldIT Data Sheet 10/11 8.64 EN Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation Level 0: Information • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    PDF TH202/TH202-Ex rosemount 1144 rosemount pt 100 rtd V11523 pt100 rtd rosemount PT100 rosemount EC certificate PTB ATEX 1144 X Thermocouple Type L namur NE 43 rosemount PT 441 rosemount PT-1000 sensor

    Untitled

    Abstract: No abstract text available
    Text: Precision RTD Thermometer OMEGA SM CARE Extended Warranty Program √ √ √ √ √ √ √ √ √ √ √ NIST Traceable 4-Wire AC Bridge for Long Term Stability Without Recalibration 0.01°C Instrument Accuracy 0.025°C System Accuracy 0.001°C or 0.01°C


    Original
    PDF RS-232, IEEE-488 DP252 DP250-SP DP251 MDS41-RTD DP251, DP251-16 M-114

    Pt 100 RTD Siemens

    Abstract: circuit diagram for profibus connector siemens Siemens pt100 temperature transmitter Siemens PT100 temperature sensor RTD Thermocouple Type L Thermocouple Type g Siemens PT100 temperature sensor type s thermocouple siemens Pt100 3 wire PT-100 temperature transducer
    Text: TF 212 / TF 212-Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 100 RTD , thermocouples, 1 or 2 independent channels 10/11-8.70 EN P R O F PROCESS FIELD BUS B U S • Input – – – – Resistance thermometer (2, 3, 4-wire method) Thermocouples


    Original
    PDF 212-Ex Pt 100 RTD Siemens circuit diagram for profibus connector siemens Siemens pt100 temperature transmitter Siemens PT100 temperature sensor RTD Thermocouple Type L Thermocouple Type g Siemens PT100 temperature sensor type s thermocouple siemens Pt100 3 wire PT-100 temperature transducer