Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    380V MOTOR OVERLOAD PROTECTION Search Results

    380V MOTOR OVERLOAD PROTECTION Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    PQU650M-F-COVER Murata Manufacturing Co Ltd PQU650M Series - 3x5 Fan Cover Kit, RoHs Medical Visit Murata Manufacturing Co Ltd
    DF3D36FU Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-28 V, SOT-323 (USM), 2 protected lines, AEC-Q101 Visit Toshiba Electronic Devices & Storage Corporation
    DF3D18FU Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-12 V, SOT-323 (USM), 2 protected lines, AEC-Q101 Visit Toshiba Electronic Devices & Storage Corporation
    DF3D29FU Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-24 V, SOT-323 (USM), 2 protected lines, AEC-Q101 Visit Toshiba Electronic Devices & Storage Corporation
    TCKE712BNL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 13.2 V, 3.65 A, Latch, Adjustable Over Voltage Protection, WSON10 Visit Toshiba Electronic Devices & Storage Corporation

    380V MOTOR OVERLOAD PROTECTION Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    415v scr CIRCUIT DIAGRAM

    Abstract: 220v ac fan controller 220v motor overload protection mc 1000 scr motor controller 380V 415v motor wiring diagram forward reverse motor function 3 phase ac motor start by scr circuit 3 phase, 415v and 45 kw motor wiring diagram wiring diagram soft start FORWARD REVERSE 3 PHASE MOTOR wiring diagram
    Text: Motosoft-SN Series Protection function 1. SCR overheat protection While cooling fin is over 80+/-3 deg.C, the output stops and Err.1 red led lights. 2 Prevent to start with a short phase Starting power with short phase, Err.1 (red lamp) flashs 2 times.(Power 1/L1,3/L2, 5/L3 can't be


    Original
    PDF

    FDN36MC100GD

    Abstract: magnetic Contactor wiring diagrams and float switch CL03A FDN36MC080GD star delta FORWARD REVERSE STARTER GPF10C02 GPS1bsah LG0006P1B0 CL07A CL03A-CL04A
    Text: 39584 GE Consumer & Industrial Power Protection GE Consumer & Industrial Power Protection formerly GE Power Controls , a division of GE Consumer & Industrial, is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical


    Original
    H-1340 B-9000 C/4601/E/EX FDN36MC100GD magnetic Contactor wiring diagrams and float switch CL03A FDN36MC080GD star delta FORWARD REVERSE STARTER GPF10C02 GPS1bsah LG0006P1B0 CL07A CL03A-CL04A PDF

    catalogue

    Abstract: jigo products SCR 131- 6 WJ 59 SCR 131- 6 WJ 69 SCR 131- 6 WJ 68 SCR 131- 6 WJ 60 LC1-D32 SCR 131- 6 WJ 67 SCR 131- 6 WJ 65 ST3PA
    Text: JiGO PRODUCTS CATALOGUE it all began in 1987…. The founder hit upon the electrical business in 1987 in the financial hub of eastern India, Kolkata. In midst of severe competition and tough markets, their values and committment towards quality and customer service set them apart from


    Original
    JG-GV3-M06 JG-GV3-M07 JG-GV3-M08 JG-GV3-M10 JG-GV3-M14 JG-GV3-M20 JG-GV3-M25 JG-GV3-M40 JG-GV3-M63 JG-GV3-M80 catalogue jigo products SCR 131- 6 WJ 59 SCR 131- 6 WJ 69 SCR 131- 6 WJ 68 SCR 131- 6 WJ 60 LC1-D32 SCR 131- 6 WJ 67 SCR 131- 6 WJ 65 ST3PA PDF

    NFC 63210

    Abstract: 125C22X58AM
    Text: CYLINDER Cylinder Fuses are typically used in industrial applications to protect electrical devices such as motors, drives, etc. They are available in four sizes with a current range from 1 to 125 Amps. Cylinder Fuses have metal caps at both ends, and a porcelain fuse body.


    Original
    8C14x51SC 10C14x51SC 12C14x51SC 16C14x51SC 20C14x51SC 25C14x51SC 32C14x51SC 40C14x51SC 50C14x51SC 1/660V NFC 63210 125C22X58AM PDF

    FR-PA02-02

    Abstract: 380v motor overload protection E540 mITSUBISHI FANS e500 mitsubishi FR-PU04 inverter 3 phase output 380v 380V electric motor Mitsubishi Elevators inverter panel k 3531 transistor
    Text: PRODUCT FROM MITSUBISHI E500 SERIES A N E W B R E E D O F C O M PA C T D R I V E that’s faster to set up and go Yo u r p a r t n e r i n a u t o m a t i o n s y s t e m s Plug in for instant compatibility no other compact drive works faster The exciting and special


    Original
    Mx500 BRO-E500-0599-GKL FR-PA02-02 380v motor overload protection E540 mITSUBISHI FANS e500 mitsubishi FR-PU04 inverter 3 phase output 380v 380V electric motor Mitsubishi Elevators inverter panel k 3531 transistor PDF

    single phase DOL starter wiring

    Abstract: abb dol starter wiring to motor 3 phase, 415v and 37 kw motor 326-166 bobina de encendido abb dol starter wiring 32M40 AC11 dol starter connections 380V 415v motor
    Text: Issued / Herausgegeben / Publicado / Publication Publicatto / Udgivet / Afgegeven / Utgiven 04/2002 V8721 0.5 to 10hp 415V Direct on Line Starter Direktstarter, 0,5-10 PS, 415 V Instruction Leaflet Bedienungsanleitung Hojas de instrucciones Feuille d’instructions


    Original
    V8721 single phase DOL starter wiring abb dol starter wiring to motor 3 phase, 415v and 37 kw motor 326-166 bobina de encendido abb dol starter wiring 32M40 AC11 dol starter connections 380V 415v motor PDF

    3phase winding data 3.7 kw to 110 kw

    Abstract: J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v
    Text: Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessories • front mounted single pole additional auxiliary contacts


    Original
    380/415V) J7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v PDF

    touch switch using ic 4011

    Abstract: DD862 DELIXI DELIXI DW17 DT862 applications touch switch cd 4011 delixi dz47le air circuit breaker automatic brake failure indicator and engine heating alarm DZ108
    Text: 2005 General Catalog General Contents Circuit Breaker Series Contactor & Relay Series Instruments & Meters Series Temperature Indicating Controller Power Supply Series Indicator and Pushbutton Switchs 3/83-3/180 4/181-4/206 5/207-5/220 Fuse Series Rheostat Series


    Original
    CDB17 CDI9000 touch switch using ic 4011 DD862 DELIXI DELIXI DW17 DT862 applications touch switch cd 4011 delixi dz47le air circuit breaker automatic brake failure indicator and engine heating alarm DZ108 PDF

    SC-05 Fuji

    Abstract: SC03Y square d starter type sc03 Fuji 3pole 3 phase magnetic Contactor SC-N* "Fuji" SCN5 KK05-042 SC-03RM TR-N3 SC03 Index 1
    Text: Magnetic Contactors and Starters General information 01 FUJI low-voltage contactors and starters are available in a broad choice of types, from high-performance to economy, for all consumer and industrial needs. For standard applications, we offer the highperformance SC series. We offer the


    Original
    SC-03 WN11J SZ-WN10RJ SZ-WN11RJ SW-N10RM/3H SW-N11RM/3H, N12RM/3H SC-05 Fuji SC03Y square d starter type sc03 Fuji 3pole 3 phase magnetic Contactor SC-N* "Fuji" SCN5 KK05-042 SC-03RM TR-N3 SC03 Index 1 PDF

    NFC 63210

    Abstract: fuse 32A 10x38 siemens siemens diazed gg vde 0636 iec 269 22x58 fuse fuse 1.25 A 10x38 500V 63210 neozed 100 microfarad 20v capacitor 22X58
    Text: NEXT FIND IT TABLE OF CONTENTS MINIATURE DIAZED Mini fuses in five sizes to 20 Amps. • Slow Blow • Medium Blow Click for PDF file • Fast Blow • Super Fast Blow NEOZED CYLINDER NH "Bottle" fuses in five sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are


    Original
    CB2258-1 CB2258-1N CB2258-2 CB2258-3 CB2258-3N NFC 63210 fuse 32A 10x38 siemens siemens diazed gg vde 0636 iec 269 22x58 fuse fuse 1.25 A 10x38 500V 63210 neozed 100 microfarad 20v capacitor 22X58 PDF

    interposing relay

    Abstract: Allen-Bradley auxiliary contact 595-A 500F-BOD930 592-EUTB 592-EEHE 509-FOD 599-KA04 509-BOD Bulletin 709 Motor Starter Coil 599-k04
    Text: Bulletin 500 Line Open Type Modular Kits and Components Selection Guide Bulletin 500, 500F, 509 NEMA AC Contactors and Starters Product Overview NEMA AC Contactor and Starter Modular Kits and Components NEMA sizes 0…4 for open-type Bulletin 500 top-wired contractors, Bulletin 500F feed-through contactors, and Bulletin 509 fullvoltage starters, are provided as modular kits for faster delivery. Other sizes and enclosed-type devices are also available.


    Original
    800T/H 500-SG008A-EN-P interposing relay Allen-Bradley auxiliary contact 595-A 500F-BOD930 592-EUTB 592-EEHE 509-FOD 599-KA04 509-BOD Bulletin 709 Motor Starter Coil 599-k04 PDF

    NFC 63210

    Abstract: SCR 30A 500V IEC 269 63210 NFC 63210 22x58 63211 32A-100A CB832 20C10x38SC 14X51
    Text: PREVIOUS HOME NEXT FIND IT CYLINDER Cylinder Fuses are typically used in industrial applications to protect electrical devices such as motors, drives, etc. They are available in four sizes with a current range from 1 to 125 Amps. Cylinder Fuses have metal caps at both


    Original
    CB2258-1 CB2258-1N CB2258-2 CB2258-3 CB2258-3N NFC 63210 SCR 30A 500V IEC 269 63210 NFC 63210 22x58 63211 32A-100A CB832 20C10x38SC 14X51 PDF

    XTRE10B31

    Abstract: XTMC9A10 380v type 2 coordination chart XTMC9A01 XTREC10B31 VDE 0660 iec 337 pt XTREC10B40 capacitor K1M 103 IEC EN 60947- 3 VDE 0660 107 Pub51210
    Text: IEC Contactors and Starters IEC Contactors and Starters 1.1 XT IEC Power Control Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    C440/XT CA08100006Eâ V5-T1-253 XTRE10B31 XTMC9A10 380v type 2 coordination chart XTMC9A01 XTREC10B31 VDE 0660 iec 337 pt XTREC10B40 capacitor K1M 103 IEC EN 60947- 3 VDE 0660 107 Pub51210 PDF

    NEC J302 transistor

    Abstract: TRANSISTOR J601 nec j303 CMOS J601 380V 415v motor FLA Transistor J601 53 414 LEM DIODE step transformer 415V 50HZ 15V J103 NEC J302, replacement
    Text: ALLEN-BRADLEY Bulletin 1335 Variable Torque AC Drive 12 through 96 Amp Instruction Manual Important User Information Because of the variety of uses for this equipment and because of the differences between this solid state equipment and electromechanical


    OCR Scan
    PDF

    3phase winding data 3.7 kw to 110 kw

    Abstract: 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor
    Text: Motor Contactor Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW W • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessoires • front mounted d single pole additional auxiliary contacts


    Original
    380/415V) Conta7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor PDF

    telemecanique contactor catalogue

    Abstract: telemecanique contactor SIZE 1 telemecanique LC1 Telemecanique MOTOR STARTER table IEC 292-1 3 phase Overload Telemecanique telemecanique thermal overload relay telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE "IEC 292-1"
    Text: Issued November 1991 B12570 Direct on line DOL starters TelemecaniqueÔd2Õ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique Ôd2Õ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and VDE 0660. RS stock no.


    Original
    B12570 BS4941 corr32 2xPE13 2xPE16 telemecanique contactor catalogue telemecanique contactor SIZE 1 telemecanique LC1 Telemecanique MOTOR STARTER table IEC 292-1 3 phase Overload Telemecanique telemecanique thermal overload relay telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE "IEC 292-1" PDF

    FUSE SIEMENS neozed

    Abstract: FUSE SIEMENS neozed 6A fuse base IEC 269 FUSE SIEMENS neozed 2A Neozed 10A 250V slow blow glass fuse SIEMENS NH FUSE royal fuse Fuse 250V 4A Neozed fuses gL/gG
    Text: NEXT FIND IT TABLE OF CONTENTS MINIATURE DIAZED Mini fuses in five sizes to 20 Amps. • Slow Blow • Medium Blow Click for PDF file • Fast Blow • Super Fast Blow NEOZED CYLINDER NH "Bottle" fuses in five sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are


    Original
    NZ01B NZ02B NZ03B NZ01BC NZ02BC NZ03BC NZ01B3 NZ02B3 NZ01BC3 NZ02BC3 FUSE SIEMENS neozed FUSE SIEMENS neozed 6A fuse base IEC 269 FUSE SIEMENS neozed 2A Neozed 10A 250V slow blow glass fuse SIEMENS NH FUSE royal fuse Fuse 250V 4A Neozed fuses gL/gG PDF

    royal fuse

    Abstract: 5sb25 SIEMENS NH FUSE
    Text: TABLE OF CONTENTS MINIATURE DIAZED 20 Amps. • • • • NEOZED CYLINDER NH "Bottle" fuses in ve sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are Amps. 100 Amps. available in four sizes to 125 Amps, with or without blown • gL/gG - Slow Blow


    Original
    NZ01C NZ02C NZ03C 5SH5002 5SH5004 5SH5006 5SH5010 5SH5020 5SH5025 5SH5035 royal fuse 5sb25 SIEMENS NH FUSE PDF

    Contactor iec 947-4-1

    Abstract: IEC 947-4-1 J73KN-AM-22 J73KN-AM-11 J7KNA-09-01 J73KN-AM-02 380V 415v motor 380V 415v motor 100 hp iec 947-4-1 400v relay contactor wiring diagrams
    Text: Mini Motor Contactor J7KNA Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail ) • Range from 4 to 5.5 kW ( AC 3 ,380/415V ) • 4 -main pole version ( 4 kW AC and DC coil ) • Auxiliary contacts suitable for electronic devices ( DIN 19240 )


    Original
    380/415V DC24V DC48V DC60V DC110V J7KNA-09. J7KNA-12. J73KN-A. J506-E2-01 Contactor iec 947-4-1 IEC 947-4-1 J73KN-AM-22 J73KN-AM-11 J7KNA-09-01 J73KN-AM-02 380V 415v motor 380V 415v motor 100 hp iec 947-4-1 400v relay contactor wiring diagrams PDF

    Contactor iec 947-4-1

    Abstract: J7KNA-09-01 J73KN-AM-11 IEC 947-4-1 J7KNA-09-10 J73KN-AM-22 380V 415v motor motor thermal relay VDE 0660 IEC 947-5-1 VDE 0660 DC contactor 220V
    Text: Mini Motor Contactor Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail ) • Range from 4 to 5.5 kW W ( AC 3 ,380/415V ) • 4 -main pole version ( 4 kW AC and DC coil ) • Auxiliary contacts suitable for electronic devices ( DIN


    Original
    380/415V DC24V DC48V DC110V DC125V DC24V J7KNA-09. J7KNA-12. J73KN-A. J506-E2-01 Contactor iec 947-4-1 J7KNA-09-01 J73KN-AM-11 IEC 947-4-1 J7KNA-09-10 J73KN-AM-22 380V 415v motor motor thermal relay VDE 0660 IEC 947-5-1 VDE 0660 DC contactor 220V PDF

    3.7 KW induction motor 440v 3phase

    Abstract: contactor and overload start stop VDE0660 3 phase, 415v and 15 kw motor 1 KW induction motor 440v 3phase 3 phase squirrel cage induction motor remote control circuit of a phase induction motor 0.5 hp 3-PHASE induction motor bs5424 3 phase, 415v and 11 kw induction motor
    Text: Issued November 1990 B11044 Direct on line dol starters 0.5 to 10hp415Vac Features l Protected to IP54 l Robust sheet steel enclosure l 3-pole contactor to BS5424; IEC158-1 and VDE0660 l 20mm conduit entries. Robust direct on line ac starters complying with


    Original
    B11044 415Vac BS4941; IEC292 VDE0660. BS5424; IEC158-1 VDE0660 220/240V 380/440V 3.7 KW induction motor 440v 3phase contactor and overload start stop 3 phase, 415v and 15 kw motor 1 KW induction motor 440v 3phase 3 phase squirrel cage induction motor remote control circuit of a phase induction motor 0.5 hp 3-PHASE induction motor bs5424 3 phase, 415v and 11 kw induction motor PDF

    230V 5A OMRON Auxiliary RELAY

    Abstract: star delta wiring diagram with pneumatic timer 220-240v varistor 230V 5A OMRON RELAY NC Contacts J73KN-b-01 transformer winding formula 220v Ac to 110v Ac 3phase winding data 3.7 kw to 110 kw J7KN-14-10 AC415-440V timer omron J74KN-LG-9030
    Text: Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 37 kW • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof (BGV A2) • System contactors for Fuseless Load Feeders with integrated


    Original
    380/415V) omron247 J06E-EN-01A 230V 5A OMRON Auxiliary RELAY star delta wiring diagram with pneumatic timer 220-240v varistor 230V 5A OMRON RELAY NC Contacts J73KN-b-01 transformer winding formula 220v Ac to 110v Ac 3phase winding data 3.7 kw to 110 kw J7KN-14-10 AC415-440V timer omron J74KN-LG-9030 PDF

    telemecanique contactor catalogue

    Abstract: telemecanique VDE 0660 telemecanique DOL motor starter telemecanique LC1 IEC 292-1 telemecanique lc1 contactor catalogue telemecanique thermal overload relay Telemecanique MOTOR STARTER table telemecanique contactor catalogue LC1 contactor telemecanique LC1
    Text: Issued November 1991 012-570 Data Pack B Data Sheet Direct on line DOL starters Telemecanique ‘d2’ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique ‘d2’ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and


    Original
    BS4941 2xPE16 telemecanique contactor catalogue telemecanique VDE 0660 telemecanique DOL motor starter telemecanique LC1 IEC 292-1 telemecanique lc1 contactor catalogue telemecanique thermal overload relay Telemecanique MOTOR STARTER table telemecanique contactor catalogue LC1 contactor telemecanique LC1 PDF

    709 series K Allen-Bradley Starter

    Abstract: Allen-Bradley auxiliary contact 595-A Allen-Bradley starter 709 A2JD Allen-Bradley auxiliary contact 595-AB westinghouse contactor 195-FA11 interposing relay 196-fta smp1 OVERLOAD RELAY
    Text: Bulletin 509 NEMA Full Voltage Starters Bulletin 509 D Broad Range of NEMA Sizes 00–9 D Exceptional Electrical Life D UL Certified Type 2 Coordination D Dependable Coil Operation D Cost Saving Design D SMP–1 or SMP–3 Solid-State Overload Relays


    Original
    PDF