Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    12V DC RELAY 5PIN Search Results

    12V DC RELAY 5PIN Result Highlights (6)

    Part ECAD Model Manufacturer Description Download Buy
    TLP2304 Toshiba Electronic Devices & Storage Corporation Photocoupler (photo-IC output), High-speed / IPM driver, 1 Mbps, 3750 Vrms, 5pin SO6 Visit Toshiba Electronic Devices & Storage Corporation
    MGN1S1212MC-R7 Murata Manufacturing Co Ltd DC-DC 1W SM 12-12V GAN Visit Murata Manufacturing Co Ltd
    MGN1S0512MC-R7 Murata Manufacturing Co Ltd DC-DC 1W SM 5-12V GAN Visit Murata Manufacturing Co Ltd
    D1U54T-M-2500-12-HB4C Murata Manufacturing Co Ltd 2.5KW 54MM AC/DC 12V WITH 12VDC STBY BACK TO FRONT AIR Visit Murata Manufacturing Co Ltd
    D1U74T-W-1600-12-HB4AC Murata Manufacturing Co Ltd AC/DC 1600W, Titanium Efficiency, 74 MM , 12V, 12VSB, Inlet C20, Airflow Back to Front, RoHs Visit Murata Manufacturing Co Ltd
    PQU650-12P Murata Manufacturing Co Ltd AC/DC 650W, 6”X4” U-CHANNEL, 12V O/P Visit Murata Manufacturing Co Ltd

    12V DC RELAY 5PIN Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    TXD2-12V

    Abstract: TXD2-24V TXD2-H-12V TXD2-H-24V TXD2-L-12V TXD2-L-24V TXD2-L-H-12V TXD2-L-H-24V 6v 5 pin relay
    Text: TX-D TESTING New Stronger Surge Breakdown Type 6,000 V Conforming to the supplementary insulation class of EN Standards (EN60950) 3. 2,000 V breakdown voltage between contact and coil. The body block construction of the coil that is sealed formation offers a high


    Original
    PDF EN60950) 200mW TXD2-12V TXD2-24V TXD2-H-12V TXD2-H-24V TXD2-L-12V TXD2-L-24V TXD2-L-H-12V TXD2-L-H-24V 6v 5 pin relay

    TXD2-3V

    Abstract: TXD2-2M-12V TXD2-24V TXD2-2M-5V AgPd 9v RELAY WITH 5 PIN 9v RELAY relay 5v 4 pin relay 6v 5 pin relay 6v dc
    Text: TX-D TESTING New Stronger Surge Breakdown Type 6,000 V . Conforming to the supplementary insulation class of EN Standards (EN60950) 2. Approved to the supplementary insulation class in the EN standards (EN60950) The insulation distance between the contact and coil meet the


    Original
    PDF EN60950) EN60950 110509J TXD2-3V TXD2-2M-12V TXD2-24V TXD2-2M-5V AgPd 9v RELAY WITH 5 PIN 9v RELAY relay 5v 4 pin relay 6v 5 pin relay 6v dc

    TXD2-24V-6

    Abstract: TXD2-2M-5V
    Text: Productsmarked marked Products TX-D arediscontinued discontinuedas asofofAugust August31, 31,2011 2011 are High breakdown voltage type is available 1.5 kV between open contacts Products to be discontinued. FEATURES 1. Lineup now includes high breakdown voltage type that


    Original
    PDF 500gf} 010611D TXD2-24V-6 TXD2-2M-5V

    Untitled

    Abstract: No abstract text available
    Text: Data Industrial Series 3100 Dual Channel Monitor/Controller/Transmitter CTL-UM-01026-EN-04 August 2014 User Manual Data Industrial® Series 3100, Dual Channel Monitor/Controller/Transmitter Page ii August 2014 User Manual CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5


    Original
    PDF CTL-UM-01026-EN-04 109/B 941700-0031-EN

    TXD2-3V

    Abstract: TXD2-2M-12V tube 6v6 TXD2-12V TXD2-24V TXD2-H-12V TXD2-H-24V TXD2-L-12V TXD2-L-24V TXD2-L-H-12V
    Text: TX-D Discontinued as of August 31, 2011 Discontinued as of August 31, 2011 High breakdown voltage type is available 1.5 kV between open contacts 3. 3,000 V breakdown voltage between contact and coil. (Surge breakdown voltage 6,000 V type) The body block construction of the coil


    Original
    PDF EN60950) 500gf} 011010J TXD2-3V TXD2-2M-12V tube 6v6 TXD2-12V TXD2-24V TXD2-H-12V TXD2-H-24V TXD2-L-12V TXD2-L-24V TXD2-L-H-12V

    TQ4-24V

    Abstract: tq2-24v TQ2-L2-5V tq4l2-5v TQ4-L2-12V TQ2-L2-9V TQ4-5V Matsua TQ2-l2-12v relay TQ4-L2-12V TQ4H-12V
    Text: TQ LOW PROFILE 2 FORM C & 4 FORM C RELAY RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ FEATURES 1. Flat compact size 14.0 L x 9.0(W) × 5.0(H) .551(L) × .354(W) × .197(H) 2. Nominal operating power: High sensitivity of 140mW (2 Form C


    Original
    PDF 140mW TQ4-24V tq2-24v TQ2-L2-5V tq4l2-5v TQ4-L2-12V TQ2-L2-9V TQ4-5V Matsua TQ2-l2-12v relay TQ4-L2-12V TQ4H-12V

    TXD2-12V-3

    Abstract: No abstract text available
    Text: TX-D Several part part numbers numbers will will be be discontinued discontinued September September 30, 30, 2013. 2013. Several High breakdown voltage type is available 1.5 kV between open contacts 3. Several part numbers will be discontinued September 30, 2013.


    Original
    PDF EN60950) 150113D TXD2-12V-3

    AT20C

    Abstract: txd2-2m-12v 311011D 6v 5 pin relay 12V dc relay 5pin 9v RELAY WITH 5 PIN
    Text: TX-D TESTING High breakdown voltage type is available 1.5 kV between open contacts . FEATURES 1. Lineup now includes high breakdown voltage type that achieves breakdown voltage between open contacts of 1,500 V AC. Surge breakdown voltage between open contacts:


    Original
    PDF 311011D AT20C txd2-2m-12v 311011D 6v 5 pin relay 12V dc relay 5pin 9v RELAY WITH 5 PIN

    TQ2-24V

    Abstract: double coil latching relays smd TQ4-3V TQ2-L2-24V TQ4-24V TQ2-L2-9V
    Text: Products marked TQ are discontinued as of August 31, 2012 Leading the market, our 5 mm 2-pole surface mount relays comply with JIS C0806 Products to be discontinued. FEATURES 1. Flat compact size 14.0 L  9.0(W)  5.0(H) .551(L)  .354(W)  .197(H)


    Original
    PDF C0806 311011J TQ2-24V double coil latching relays smd TQ4-3V TQ2-L2-24V TQ4-24V TQ2-L2-9V

    ASX20003

    Abstract: ASX20006 ASX20009 ASX20012 ASX2001H ASX20024 ASX2004H ASX21003 ASX21006 ASX2101H
    Text: SX ASX Discontinued Discontinued as as of of August August 31, 31, 2011 2011 HIGH SENSIBILITY RELAY WITH GUARANTEED LOW LEVEL SWITCHING CAPACITY SX RELAYS (ASX) FEATURES 1. High contact reliability over a long life has been made possible for low level loads.


    Original
    PDF 500gf} 011010J ASX20003 ASX20006 ASX20009 ASX20012 ASX2001H ASX20024 ASX2004H ASX21003 ASX21006 ASX2101H

    DS_61023_EN_SX

    Abstract: 9v single RELAY
    Text: SX ASX Discontinued Discontinued as as of of August August 31, 31, 2011 2011 HIGH SENSIBILITY RELAY WITH GUARANTEED LOW LEVEL SWITCHING CAPACITY SX RELAYS (ASX) FEATURES 1. High contact reliability over a long life has been made possible for low level loads.


    Original
    PDF 010611J DS_61023_EN_SX 9v single RELAY

    latching RELAY 12V drive

    Abstract: latching relay 2 coil 24v ASX2004H ASX21003 ASX21006 ASX2101H ASX2104H ASX20003 ASX20006 ASX20009
    Text: SX ASX HIGH SENSIBILITY RELAY WITH GUARANTEED LOW LEVEL SWITCHING CAPACITY SX RELAYS (ASX) FEATURES 1. High contact reliability over a long life has been made possible for low level loads. Using a low level load (1 mV 10 A to 10 V 10 mA) 107 operations were


    Original
    PDF 500gf} 110509J latching RELAY 12V drive latching relay 2 coil 24v ASX2004H ASX21003 ASX21006 ASX2101H ASX2104H ASX20003 ASX20006 ASX20009

    ASX20003

    Abstract: ASX20006 ASX20009 ASX20012 ASX2001H ASX20024 ASX2004H ASX21003 ASX21006 ASX2101H
    Text: SX ASX HIGH SENSIBILITY RELAY WITH GUARANTEED LOW LEVEL SWITCHING CAPACITY SX RELAYS (ASX) FEATURES 1. High contact reliability over a long life has been made possible for low level loads. Using a low level load (1 mV 10 A to 10 V 10 mA) 107 operations were


    Original
    PDF 500gf} 010709J ASX20003 ASX20006 ASX20009 ASX20012 ASX2001H ASX20024 ASX2004H ASX21003 ASX21006 ASX2101H

    TQ2-L2-5V

    Abstract: TQ2-L2-9V TQ2-L-9V TQ2-5V TQ2S-5V TQ2SL-4.5V TQ2-L2-6V TQ2-5 TQ2-L2-12V TQ2-L2-24V
    Text: TQ Leading the market, our 5 mm 2-pole surface mount relays comply with JIS C0806 FEATURES 1. Flat compact size 14.0 L  9.0(W)  5.0(H) .551(L)  .354(W)  .197(H) 2. Nominal operating power: High sensitivity of 140mW (2 Form C single side stable type)


    Original
    PDF C0806 310812J TQ2-L2-5V TQ2-L2-9V TQ2-L-9V TQ2-5V TQ2S-5V TQ2SL-4.5V TQ2-L2-6V TQ2-5 TQ2-L2-12V TQ2-L2-24V

    TXD2-12V-3

    Abstract: No abstract text available
    Text: TX-D TESTING High breakdown voltage type is available 1.5 kV between open contacts 2. Approved to the supplementary insulation class in the EN standards (EN60950). The insulation distance between the contact and coil meet the supplementary insulation class of the


    Original
    PDF EN60950) EN60950 500gf} TXD2-12V-3

    DB02A

    Abstract: TXD2-3V 5v dc relay connection TXD2SA-24V TXD2-2M-12V 9v relay switch TXD2-5V TXD2-L-4.5V TXD2-12V-3 TXD2-24V
    Text: TX-D TESTING High breakdown voltage type is available 1.5 kV between open contacts New Compliance with RoHS Directive 2. Approved to the supplementary insulation class in the EN standards (EN60950). The insulation distance between the contact and coil meet the


    Original
    PDF EN60950) EN60950 amplit24 500gf} DB02A TXD2-3V 5v dc relay connection TXD2SA-24V TXD2-2M-12V 9v relay switch TXD2-5V TXD2-L-4.5V TXD2-12V-3 TXD2-24V

    TQ2-L2-5V

    Abstract: TQ4-24V TQ2-24V TQ2-L2-24V TQ2-l2-12V TQ2-L2-9V TQ4-L2-24V TQ2-5V TQ4-5V TQ2-48V
    Text: TQ Leading the market, our 5 mm 2-pole surface mount relays comply with JIS C0806 FEATURES 1. Flat compact size 14.0 L x 9.0(W) × 5.0(H) .551(L) × .354(W) × .197(H) 2. Nominal operating power: High sensitivity of 140mW (2 Form C single side stable type)


    Original
    PDF C0806 140mW 010709J TQ2-L2-5V TQ4-24V TQ2-24V TQ2-L2-24V TQ2-l2-12V TQ2-L2-9V TQ4-L2-24V TQ2-5V TQ4-5V TQ2-48V

    relay 12v dc 5pin

    Abstract: 9v RELAY WITH 5 PIN TXD2-12V-3
    Text: TX-D TESTING High breakdown voltage type is available 1.5 kV between open contacts RoHS compliant 1. Lineup now includes high breakdown voltage type that achieves breakdown voltage between open contacts of 1,500 V AC. Surge breakdown voltage between open contacts:


    Original
    PDF EN60950) EN60950 ASCTB19E 201201-T relay 12v dc 5pin 9v RELAY WITH 5 PIN TXD2-12V-3

    TXD2-2M-5V

    Abstract: transistor bel 100 12V dc relay 5pin
    Text: TX-D TESTING High breakdown voltage type is available 1.5 kV between open contacts RoHS compliant 1. Lineup now includes high breakdown voltage type that achieves breakdown voltage between open contacts of 1,500 V AC. Surge breakdown voltage between open contacts:


    Original
    PDF EN60950) EN60950 55ore ASCTB19E 201209-T TXD2-2M-5V transistor bel 100 12V dc relay 5pin

    Untitled

    Abstract: No abstract text available
    Text: TX-D High Breakdown Voltage Relay RoHS compliant FEATURES 1. Approved to the supplementary insulation class in the EN standards EN60950 . The insulation distance between the contact and coil meet the supplementary insulation class of the EN60950 standards as required for


    Original
    PDF EN60950) EN60950 200mW ASCTB19E 201209-T

    Untitled

    Abstract: No abstract text available
    Text: Discontinued as of August 31, 2011 SX ASX HIGH SENSIBILITY RELAY WITH GUARANTEED LOW LEVEL SWITCHING CAPACITY SX RELAYS (ASX) FEATURES Compliance with RoHS Directive 1. High contact reliability over a long life has been made possible for low level loads.


    Original
    PDF

    double coil latching relays

    Abstract: relay 6v 5 pin ASX20003 ASX20006 ASX20009 ASX20012 ASX2001H ASX20024 ASX2004H ASX21003
    Text: SX ASX HIGH SENSIBILITY RELAY WITH GUARANTEED LOW LEVEL SWITCHING CAPACITY SX RELAYS (ASX) FEATURES Compliance with RoHS Directive 1. High contact reliability over a long life has been made possible for low level loads. Using a low level load (1 mV 10µA to


    Original
    PDF 500gf} double coil latching relays relay 6v 5 pin ASX20003 ASX20006 ASX20009 ASX20012 ASX2001H ASX20024 ASX2004H ASX21003

    M215

    Abstract: ASCTB14E TQ2-L2-6V relay TQ4-L2-12V TQ4-L2-12V
    Text: TQ Leading the market, our 5 mm 2-pole surface mount relays comply with JIS C0806 By using the highly efficient polar magnetic circuit “seesaw balance mechanism”, a nominal operating power of 140 mW minimum operating power of 79 mW has been achieved


    Original
    PDF C0806 ASCTB14E 201201-T M215 TQ2-L2-6V relay TQ4-L2-12V TQ4-L2-12V

    relay tx-2

    Abstract: TX2-24V 300108J TX2-12V TX2-48V TX2-H-12V TX2-H-24V TX2-H-48V TX2-L-12V TX2-L2-12V
    Text: TX TESTING 2 A CAPACITY RELAY WITH HIGH SURGE BREAKDOWN VOLTAGE & HIGH BREAKDOWN VOLTAGE FEATURES 1. 2,000 V breakdown voltage between contact and coil The body block construction of the coil that is sealed at formation offers a high breakdown voltage of 2,000 V between


    Original
    PDF 140mW 300108J relay tx-2 TX2-24V 300108J TX2-12V TX2-48V TX2-H-12V TX2-H-24V TX2-H-48V TX2-L-12V TX2-L2-12V