Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    "SINGLE SHOT" DIGITIZER Search Results

    "SINGLE SHOT" DIGITIZER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DCL541A01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Input disable Visit Toshiba Electronic Devices & Storage Corporation
    DCL542H01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=2:2) / Default Output Logic: High / Output enable Visit Toshiba Electronic Devices & Storage Corporation
    DCL541B01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: High / Input disable Visit Toshiba Electronic Devices & Storage Corporation
    DCL542L01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=2:2) / Default Output Logic: Low / Output enable Visit Toshiba Electronic Devices & Storage Corporation
    DCL540H01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=4:0) / Default Output Logic: High / Output enable Visit Toshiba Electronic Devices & Storage Corporation

    "SINGLE SHOT" DIGITIZER Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    bnc female connector

    Abstract: 16000ks 5102 16 PIN euro connectors ma 5102
    Text: 15 MHz, 20 MS/s 8-Bit Digitizer NI 5102 NI 5102 Analog Input Application Software 20 MS/s per channel real-time sampling 1 GS/s random interleaved sampling 8 bits vertical resolution ±50 mV to ±50 V input range 15 MHz bandwidth 2 simultaneously sampled channels


    Original
    PDF

    NI PXI-5112

    Abstract: 9pin din catalog of oscilloscope PCI 6602
    Text: 100 MHz, 100 MS/s 8-Bit Digitizer NI 5112 NI 5112 Analog Input Application Software 100 MS/s real-time sampling 2.5 GS/s random interleaved sampling 8 bits vertical resolution 100 MHz bandwidth ±25 mV to ±25 V input range ±50 VDC maximum offset 1 MΩ or 50 Ω input impedance


    Original
    PDF

    FLUKE 75 series II multimeter

    Abstract: FLUKE 123 manual fluke bp120 BP130 SERVICE MANUAL OF FLUKE 175 FLUKE 196C manual BP190 MIL-PRF-2800F FLUKE 70 series II multimeter PM9080
    Text: Technical Specifications ScopeMeter 120 Series Oscilloscope Mode Cursor Measurements 124 only Vertical deflection Sources: Input A, Input B Modes: Single or dual vertical cursor, dual horizontal cursor, rise- or falltime Measurements: Single vertical line: Average, min value, max value,


    Original
    VPS40 STL120 -36-FLUKE FLUKE 75 series II multimeter FLUKE 123 manual fluke bp120 BP130 SERVICE MANUAL OF FLUKE 175 FLUKE 196C manual BP190 MIL-PRF-2800F FLUKE 70 series II multimeter PM9080 PDF

    SCOPEMETER Fluke 99

    Abstract: FLUKE 75 series II multimeter fluke 75 meter manual FLUKE Clamp meter diagram PM9080 DPU-414 FLUKE 70 series II multimeter fluke bp120 FLUKE 30 Clamp meter diagram FLUKE 123
    Text: No w an en d ha FF n T ce Sp d ec wit tru h m 3K An m al em ys or is y ScopeMeter 190 Series YM IT ANAGEMENT Technical Data SY S  M TE QU AL and ScopeMeter® 120 Series CE R TI 00 1 ISO 9001 FI E O D T O EET IS M 9 R ScopeMeter 190 Series: Speed, performance and analysis power


    Original
    RS-232 10705-eng SCOPEMETER Fluke 99 FLUKE 75 series II multimeter fluke 75 meter manual FLUKE Clamp meter diagram PM9080 DPU-414 FLUKE 70 series II multimeter fluke bp120 FLUKE 30 Clamp meter diagram FLUKE 123 PDF

    SCOPEMETER Fluke 99

    Abstract: No abstract text available
    Text: ScopeMeter 190C, 190B, and 120 Series Technical Data ANAGEMENT S YM Y IT  CE RT IF IE D 90 01 EM ST QU AL ScopeMeter 190C and 190B Series: Speed, performance and analysis power TO MEET IS O For demanding applications, the ScopeMeter 190C and 190B Series


    Original
    -36-FLUKE SCOPEMETER Fluke 99 PDF

    SCOPEMETER Fluke 99

    Abstract: No abstract text available
    Text: ScopeMeter 120 and 190 Series incl. 225C and 215C ScopeMeter 215C, 225C and 190C Series: Speed, performance and analysis power QU AL RT IF 90 CE 01 ♦� EM ST ANAGEMENT S YM Y IT IE D TO MEET IS O For demanding applications, the ScopeMeter 215C, 225C and 190C


    Original
    -36-FLUKE SCOPEMETER Fluke 99 PDF

    SCOPEMETER Fluke 99

    Abstract: No abstract text available
    Text: ScopeMeter 120 and 190 Series incl. 225C and 215C ScopeMeter 215C, 225C and 190C Series: Speed, performance and analysis power QU AL RT IF ED 90 CE 01  EM ST ANAGEMENT S YM Y IT TO MEET IS O For demanding applications, the ScopeMeter 215C, 225C and 190C


    Original
    -36-FLUKE 1629083H SCOPEMETER Fluke 99 PDF

    Fluke 17 DMM

    Abstract: No abstract text available
    Text: ScopeMeter 120 and 190 Series incl. 225C and 215C ScopeMeter 215C, 225C and 190C Series: Speed, performance and analysis power QU AL RT IF ED 90 CE 01  EM ST ANAGEMENT S YM Y IT TO MEET IS O • Bus Health Test capability for For demanding applications, the


    Original
    -36-FLUKE 1629083H Fluke 17 DMM PDF

    ultrasonic radar

    Abstract: ballistic radar dbs907 waveform variable time delay with connector 10vfsr
    Text: DBS907 907LM/907HV 1 GS/s VXI Waveform Digitizer Plug-In Module Plugs into the Analogic DBS 9905 "C" Size VXI Carrier Module Introduction The Analogic DBS907 is a 1 GigaSamples/second Waveform Digitizer that plugs into the DBS 9905 “C” size VXI carrier module. One or two DBS907s can


    Original
    DBS907 907LM/907HV DBS907 DBS907s DBS907B DBS907LM DBS907LMB ultrasonic radar ballistic radar waveform variable time delay with connector 10vfsr PDF

    908B

    Abstract: dbs9905
    Text: DBS 908 DBS 908LM 2 GS/s VXI Waveform Digitizer Mezzanine Module For the Analogic DBS 9905 “C” Size VXI Carrier Module Introduction The high-performance DBS 908 Waveform Digitizer is a modular mezzanine board designed for use with the DBS 9905 “C” size VXI carrier module. It features a maximum sampling rate of 2 GigaSamples/second, 8-bit resolution and


    Original
    908LM 908LMB 908B dbs9905 PDF

    FLUKE 196C manual

    Abstract: FLUKE 79 series 3 user manual fluke 73 Repair manual Fluke 19 Multimeter calibration manual FLUKE 77 series II service manual FLUKE 77 series II multimeter FLUKE 79 3 series BC190/BC190 PM9080 FLUKE 79 manual
    Text: Fluke 196C/199C ScopeMeter Users Manual 4822 872 30482 October 2001 2001 Fluke Corporation. All rights reserved. Printed in the Netherlands. All product names are trademarks of their respective companies. LIMITED WARRANTY & LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is three years


    Original
    196C/199C VP200 FLUKE 196C manual FLUKE 79 series 3 user manual fluke 73 Repair manual Fluke 19 Multimeter calibration manual FLUKE 77 series II service manual FLUKE 77 series II multimeter FLUKE 79 3 series BC190/BC190 PM9080 FLUKE 79 manual PDF

    HV15HF

    Abstract: HV15HF equivalent 9pin din PXI-5102 1000X SMB200 bnc female connector
    Text: PXI-5102 20 MS/s Digital Oscilloscope PXI-5102 Available Q1 1998 Analog Input 15 MHz bandwidth 2 simultaneously sampled channels 20 MS/s per channel real-time sampling 1 GS/s random interleaved sampling 8 bits vertical resolution ±50 mV to ±5000 V input range


    Original
    PXI-5102 PXI-5102 HV15HF HV15HF equivalent 9pin din 1000X SMB200 bnc female connector PDF

    LTC1415

    Abstract: No abstract text available
    Text: advertisement LTC1415: 1.25Msps, 12-Bit ADC Conserves Power and Signal Integrity on a Single 5V Supply – Design Note 146 Kevin R. Hoskins INTRODUCTION Complete ADC with Reference and Wideband S/H The LTC1415 includes a 10ppm/°C 2.5V reference that is suitable for use as a system reference. This internal reference sets the LTC1415’s full-scale input range from 0V to


    Original
    LTC1415: 25Msps, 12-Bit LTC1415 10ppm/ LTC1415 DN146 PDF

    TEKTRONIX TDS2CM

    Abstract: Tektronix tds 210 Tektronix tds 210 oscilloscope tektronix TDS 224 tektronix TDS 200 oscilloscope tektronix TDS 220 oscilloscope TDS420A tds430A TDS2CM 7-0004
    Text: Tektronix Digitizing Oscilloscopes TDS 200 Series Digital Real-Time Oscilloscopes c c c c c c c c TDS 210 Ñ 60 MHz; TDS 220, TDS 224 Ñ 100 MHz 1 GS/s Sample Rate Channels: TDS 210, TDS 220 Ñ 2; TDS 224 Ñ 4 Dual Timebase Cursors and Measurements Autoset


    Original
    RS-232, TDS430A TDS420A TDS460A TDS426A TEKTRONIX TDS2CM Tektronix tds 210 Tektronix tds 210 oscilloscope tektronix TDS 224 tektronix TDS 200 oscilloscope tektronix TDS 220 oscilloscope TDS2CM 7-0004 PDF

    Untitled

    Abstract: No abstract text available
    Text: Agilent M9202A PXI-Express Wideband IF Digitizer Data Sheet 12-bit, 2 GS/s, 1 GHz T TM DISCOVER the Alternatives. D . Agilent MODULAR Products A p p l i c ati o ns OV ERV IE W • Aerospace and defense I n tr o du c ti o n • Wireless communication • Radar and Wideband signal capture


    Original
    M9202A 12-bit, M9202A 5990-6461EN PDF

    IEC-60068-2-64

    Abstract: IEC-60068-2-1 IEC60068-2-27 IEC-60068-2-56
    Text: PXI Modules 3030A Wideband RF Digitizer Fully featured wideband PXI RF Digitizer module for complex signal analysis applications in communications system test • Frequency range 330 MHz to 3 GHz • 36 wide MHz digitized corrected bandwidth • 14 bit A/D resolution with 103.68 MHz


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Agilent M9211A PXI-H UWB IF Digitizer Data Sheet 10-bit, 4 GS/s, 3 GHz TM DISCOVER the Alternatives. D . Agilent MODULAR Products OV ERV IE W I n tr odu c ti o n F eatures Agilent Technologies M9211A is the fastest and widest analog bandwidth 10-bit digitizer, making it ideal for Automated Test


    Original
    M9211A 10-bit, M9211A 10-bit 5990-6463EN PDF

    FLUKE 79 series 3 user manual

    Abstract: No abstract text available
    Text: ScopeMeter Test Tool 190 Series II Fluke 190-062, -102, -104, -202, -204, -502, -504 Users Manual May 2011, Rev.2, 1/14 2011-2014 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.


    Original
    hpp00 FLUKE 79 series 3 user manual PDF

    picoscope

    Abstract: ADC-212 digital oscilloscope labview picoscope spectrum analyser specifications "single shot" digitizer oscilloscope pc digital storage oscilloscope digital storage oscilloscopes spectrum analyser
    Text: pc oscilloscope and spectrum analyzer Page 1 of 1 High Resolution PC Oscilloscope / Spectrum Analyzer The ADC-212/50 & ADC-212/100 l l l l l l l High speed, 5GS/s dual channel oscilloscope 50MHz, 80db dynamic range spectrum analyzer High resolution - 12 bits.


    Original
    ADC-212/50 ADC-212/100 50MHz, ADC-212/100 100MS/s 50MHz 500mA 95/98/ME, XP/NT/2000 picoscope ADC-212 digital oscilloscope labview picoscope spectrum analyser specifications "single shot" digitizer oscilloscope pc digital storage oscilloscope digital storage oscilloscopes spectrum analyser PDF

    DC iris schematic

    Abstract: 3ccd camera A CLIPPER CIRCUIT APPLICATIONS iris scanner circuit Waveform Clipping With Schottky DB10 XRD9861 XRD98L61 XRD98L61AIV
    Text: XRD98L61 CCD Image Digitizers with CDS, PGA and 12-Bit A/D May 2001-2 FEATURES • 12-Bit Resolution ADC • 20MHz Sampling Rate • 10-Bit Programmable Gain: 0dB to 36dB PGA • Digitally Controlled Offset-Calibration with Pixel Averager and Hot Pixel Clipper


    Original
    XRD98L61 12-Bit 20MHz 10-Bit 125mW DC iris schematic 3ccd camera A CLIPPER CIRCUIT APPLICATIONS iris scanner circuit Waveform Clipping With Schottky DB10 XRD9861 XRD98L61 XRD98L61AIV PDF

    aeroflex module 3035

    Abstract: frequency synthesizer for LTE Applications settling time 3030C/3035C/3036
    Text: PXI Modules 3030 Series RF Digitizers Fully featured wideband PXI RF digitizer modules for complex signal analysis applications in communications system test • RF down converter with frequency breaks at 3 GHz, 6 GHz and 13 GHz Analyzing RF communications signals has never been more


    Original
    PDF

    schematic diagram online UPS

    Abstract: VHDCI Connector 303003 "single shot" digitizer 3030c 3035C CONNECTOR smb 2319E
    Text: 3030A, 3030C, 3035, 3035C 3030 Series Wideband RF Digitizer PXI Modules User Manual Document no. 46892/836 Issue 3 23 November 2009 PREFACE About this manual This manual explains how to set up and configure an Aeroflex 3030A, 3030C, 3035 or 3035C wideband RF digitizer PXI module. Where necessary, it refers you to the appropriate


    Original
    3030C, 3035C schematic diagram online UPS VHDCI Connector 303003 "single shot" digitizer 3030c 3035C CONNECTOR smb 2319E PDF

    XR-3470BCP

    Abstract: XR-3470ACN XR-3470ACP XR-3470BCN
    Text: 'X T EXAR XR-3470A/3470B Floppy Disk Read Amplifier GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM The XR-3470A/3470B is read amplifier system designed primarily for use in a floppy disk drive system. It is de­ signed to perform the complete readback function, by


    OCR Scan
    XR-3470A XR-3470B XR-3470A/3470B RS232C XR-1489A RS232Cto XR-1488N XR-1488P XR-1489AN XR-3470BCP XR-3470ACN XR-3470ACP XR-3470BCN PDF

    XR-3470

    Abstract: No abstract text available
    Text: 'X T E X A R XR-3470A/3470B Floppy Disk Read Amplifier GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM The XR-3470A/3470B is read amplifier system designed primarily for use in a floppy disk drive system. It is de­ signed to perform the complete readback function, by


    OCR Scan
    XR-3470A/3470B XR-3470A/3470B XR-1488 RS232C XR-1489A XR-1488N XR-1488P XR-1489AN XR-3470 PDF